Cargando…
Influence of probe pressure on the pulsatile diffuse correlation spectroscopy blood flow signal on the forearm and forehead regions
In a pilot study of 11 healthy adults (24 to 39 years, all male), we characterize the influence of external probe pressure on optical diffuse correlation spectroscopy (DCS) measurements of pulsatile blood flow obtained on the forearm and forehead. For external probe pressure control, a hand inflatab...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Society of Photo-Optical Instrumentation Engineers
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6755374/ https://www.ncbi.nlm.nih.gov/pubmed/31548976 http://dx.doi.org/10.1117/1.NPh.6.3.035013 |
_version_ | 1783453220416258048 |
---|---|
author | Wang, Detian Baker, Wesley B. He, Hui Gao, Peng Zhu, Liguo Peng, Qixian Li, Zeren Li, Fei Chen, Tunan Feng, Hua |
author_facet | Wang, Detian Baker, Wesley B. He, Hui Gao, Peng Zhu, Liguo Peng, Qixian Li, Zeren Li, Fei Chen, Tunan Feng, Hua |
author_sort | Wang, Detian |
collection | PubMed |
description | In a pilot study of 11 healthy adults (24 to 39 years, all male), we characterize the influence of external probe pressure on optical diffuse correlation spectroscopy (DCS) measurements of pulsatile blood flow obtained on the forearm and forehead. For external probe pressure control, a hand inflatable air balloon is inserted between the tissue and an elastic strap. The air balloon is sequentially inflated to achieve a wide range of external probe pressures between 20 and 250 mmHg on the forearm and forehead, which are measured with a flexible pressure sensor underneath the probe. At each probe pressure, the pulsatility index (PI) of arteriole blood flow on the forehead and forearm is measured with DCS (2.1-cm source-detector separation). We observe a strong correlation between probe pressure and PI on the forearm ([Formula: see text] , [Formula: see text]), but not on the forehead ([Formula: see text] , [Formula: see text]). The forearm measurements demonstrate the sensitivity of the DCS PI to skeletal muscle tissue pressure, whereas the forehead measurements indicate that DCS PI measurements are not sensitive to scalp tissue pressure. Note, in contrast to pulsatility, the time-averaged DCS blood flow index on the forehead was significantly correlated with probe pressure ([Formula: see text] , [Formula: see text]). This pilot data appears to support the initiation of more comprehensive clinical studies on DCS to detect trends in internal pressure in brain and skeletal muscle. |
format | Online Article Text |
id | pubmed-6755374 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Society of Photo-Optical Instrumentation Engineers |
record_format | MEDLINE/PubMed |
spelling | pubmed-67553742020-03-18 Influence of probe pressure on the pulsatile diffuse correlation spectroscopy blood flow signal on the forearm and forehead regions Wang, Detian Baker, Wesley B. He, Hui Gao, Peng Zhu, Liguo Peng, Qixian Li, Zeren Li, Fei Chen, Tunan Feng, Hua Neurophotonics Research Papers In a pilot study of 11 healthy adults (24 to 39 years, all male), we characterize the influence of external probe pressure on optical diffuse correlation spectroscopy (DCS) measurements of pulsatile blood flow obtained on the forearm and forehead. For external probe pressure control, a hand inflatable air balloon is inserted between the tissue and an elastic strap. The air balloon is sequentially inflated to achieve a wide range of external probe pressures between 20 and 250 mmHg on the forearm and forehead, which are measured with a flexible pressure sensor underneath the probe. At each probe pressure, the pulsatility index (PI) of arteriole blood flow on the forehead and forearm is measured with DCS (2.1-cm source-detector separation). We observe a strong correlation between probe pressure and PI on the forearm ([Formula: see text] , [Formula: see text]), but not on the forehead ([Formula: see text] , [Formula: see text]). The forearm measurements demonstrate the sensitivity of the DCS PI to skeletal muscle tissue pressure, whereas the forehead measurements indicate that DCS PI measurements are not sensitive to scalp tissue pressure. Note, in contrast to pulsatility, the time-averaged DCS blood flow index on the forehead was significantly correlated with probe pressure ([Formula: see text] , [Formula: see text]). This pilot data appears to support the initiation of more comprehensive clinical studies on DCS to detect trends in internal pressure in brain and skeletal muscle. Society of Photo-Optical Instrumentation Engineers 2019-09-23 2019-07 /pmc/articles/PMC6755374/ /pubmed/31548976 http://dx.doi.org/10.1117/1.NPh.6.3.035013 Text en © The Authors. Published by SPIE under a Creative Commons Attribution 4.0 Unported License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI. |
spellingShingle | Research Papers Wang, Detian Baker, Wesley B. He, Hui Gao, Peng Zhu, Liguo Peng, Qixian Li, Zeren Li, Fei Chen, Tunan Feng, Hua Influence of probe pressure on the pulsatile diffuse correlation spectroscopy blood flow signal on the forearm and forehead regions |
title | Influence of probe pressure on the pulsatile diffuse correlation spectroscopy blood flow signal on the forearm and forehead regions |
title_full | Influence of probe pressure on the pulsatile diffuse correlation spectroscopy blood flow signal on the forearm and forehead regions |
title_fullStr | Influence of probe pressure on the pulsatile diffuse correlation spectroscopy blood flow signal on the forearm and forehead regions |
title_full_unstemmed | Influence of probe pressure on the pulsatile diffuse correlation spectroscopy blood flow signal on the forearm and forehead regions |
title_short | Influence of probe pressure on the pulsatile diffuse correlation spectroscopy blood flow signal on the forearm and forehead regions |
title_sort | influence of probe pressure on the pulsatile diffuse correlation spectroscopy blood flow signal on the forearm and forehead regions |
topic | Research Papers |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6755374/ https://www.ncbi.nlm.nih.gov/pubmed/31548976 http://dx.doi.org/10.1117/1.NPh.6.3.035013 |
work_keys_str_mv | AT wangdetian influenceofprobepressureonthepulsatilediffusecorrelationspectroscopybloodflowsignalontheforearmandforeheadregions AT bakerwesleyb influenceofprobepressureonthepulsatilediffusecorrelationspectroscopybloodflowsignalontheforearmandforeheadregions AT hehui influenceofprobepressureonthepulsatilediffusecorrelationspectroscopybloodflowsignalontheforearmandforeheadregions AT gaopeng influenceofprobepressureonthepulsatilediffusecorrelationspectroscopybloodflowsignalontheforearmandforeheadregions AT zhuliguo influenceofprobepressureonthepulsatilediffusecorrelationspectroscopybloodflowsignalontheforearmandforeheadregions AT pengqixian influenceofprobepressureonthepulsatilediffusecorrelationspectroscopybloodflowsignalontheforearmandforeheadregions AT lizeren influenceofprobepressureonthepulsatilediffusecorrelationspectroscopybloodflowsignalontheforearmandforeheadregions AT lifei influenceofprobepressureonthepulsatilediffusecorrelationspectroscopybloodflowsignalontheforearmandforeheadregions AT chentunan influenceofprobepressureonthepulsatilediffusecorrelationspectroscopybloodflowsignalontheforearmandforeheadregions AT fenghua influenceofprobepressureonthepulsatilediffusecorrelationspectroscopybloodflowsignalontheforearmandforeheadregions |