Cargando…

A comparison of McGrath MAC, Pentax AWS, and Macintosh direct laryngoscopes for nasotracheal intubation: a randomized controlled trial

PURPOSE: Videolaryngoscopy in nasotracheal intubation has been reported to be better than direct laryngoscopy. The most suitable type of videolaryngoscope remains unknown. This study aimed to compare two videolaryngoscopes (McGrath MAC and Pentax AWS) with a Macintosh laryngoscope during nasotrachea...

Descripción completa

Detalles Bibliográficos
Autores principales: Chae, Yun Jeong, Kim, Dae Hee, Park, Eun Jeong, Oh, Juyeon, Yi, In Kyong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6756366/
https://www.ncbi.nlm.nih.gov/pubmed/31571890
http://dx.doi.org/10.2147/TCRM.S220451
_version_ 1783453385219899392
author Chae, Yun Jeong
Kim, Dae Hee
Park, Eun Jeong
Oh, Juyeon
Yi, In Kyong
author_facet Chae, Yun Jeong
Kim, Dae Hee
Park, Eun Jeong
Oh, Juyeon
Yi, In Kyong
author_sort Chae, Yun Jeong
collection PubMed
description PURPOSE: Videolaryngoscopy in nasotracheal intubation has been reported to be better than direct laryngoscopy. The most suitable type of videolaryngoscope remains unknown. This study aimed to compare two videolaryngoscopes (McGrath MAC and Pentax AWS) with a Macintosh laryngoscope during nasotracheal intubation. METHODS: Overall, 123 patients older than 18 with normal airways who needed nasotracheal intubation were randomly allocated into three groups: Macintosh (n=41), McGrath (n=41), and Pentax (n=41). Intubation time was the primary outcome and subdivided into three steps: nose to oropharynx, oropharynx to laryngeal inlet, and laryngeal inlet to trachea. Time required, ease of each step, glottic view grade, modified nasal intubation–difficulty score, and subjective difficulty were evaluated. RESULTS: Intubation time among the three groups was not significantly different (Macintosh 34.6±8.1 seconds, McGrath 35.2±7.9 seconds, Pentax 36.2±9.7 seconds; p=0.727). While the glottal view was better with videolaryngoscopes (I/IIa/IIb/III 36.6%/36.6%/19.5%/7.3% vs 82.9%/9.8%/7.3%/0%, vs 63.4%/29.3%/4.9%/2.4%, p=0.000), modified nasal intubation–difficulty score and subjective difficulty and ease of each step were not significantly different. However, the Pentax took longest for the second step (11.8±6.3 vs 10.3±3.5 vs 15.1±7.6 seconds, p=0.001) but was shortest for the third step (2.9±2.6 vs 4.4±5.6 vs 1.7±0.7 seconds, p=0.001). CONCLUSION: The McGrath MAC and Pentax AWS showed no benefits in intubation time or difficulty, despite better glottal views, compared to the Macintosh laryngoscope in nasotracheal intubation. Additionally, videolaryngoscopes had variable performance at different steps of nasotracheal intubation.
format Online
Article
Text
id pubmed-6756366
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Dove
record_format MEDLINE/PubMed
spelling pubmed-67563662019-09-30 A comparison of McGrath MAC, Pentax AWS, and Macintosh direct laryngoscopes for nasotracheal intubation: a randomized controlled trial Chae, Yun Jeong Kim, Dae Hee Park, Eun Jeong Oh, Juyeon Yi, In Kyong Ther Clin Risk Manag Original Research PURPOSE: Videolaryngoscopy in nasotracheal intubation has been reported to be better than direct laryngoscopy. The most suitable type of videolaryngoscope remains unknown. This study aimed to compare two videolaryngoscopes (McGrath MAC and Pentax AWS) with a Macintosh laryngoscope during nasotracheal intubation. METHODS: Overall, 123 patients older than 18 with normal airways who needed nasotracheal intubation were randomly allocated into three groups: Macintosh (n=41), McGrath (n=41), and Pentax (n=41). Intubation time was the primary outcome and subdivided into three steps: nose to oropharynx, oropharynx to laryngeal inlet, and laryngeal inlet to trachea. Time required, ease of each step, glottic view grade, modified nasal intubation–difficulty score, and subjective difficulty were evaluated. RESULTS: Intubation time among the three groups was not significantly different (Macintosh 34.6±8.1 seconds, McGrath 35.2±7.9 seconds, Pentax 36.2±9.7 seconds; p=0.727). While the glottal view was better with videolaryngoscopes (I/IIa/IIb/III 36.6%/36.6%/19.5%/7.3% vs 82.9%/9.8%/7.3%/0%, vs 63.4%/29.3%/4.9%/2.4%, p=0.000), modified nasal intubation–difficulty score and subjective difficulty and ease of each step were not significantly different. However, the Pentax took longest for the second step (11.8±6.3 vs 10.3±3.5 vs 15.1±7.6 seconds, p=0.001) but was shortest for the third step (2.9±2.6 vs 4.4±5.6 vs 1.7±0.7 seconds, p=0.001). CONCLUSION: The McGrath MAC and Pentax AWS showed no benefits in intubation time or difficulty, despite better glottal views, compared to the Macintosh laryngoscope in nasotracheal intubation. Additionally, videolaryngoscopes had variable performance at different steps of nasotracheal intubation. Dove 2019-09-18 /pmc/articles/PMC6756366/ /pubmed/31571890 http://dx.doi.org/10.2147/TCRM.S220451 Text en © 2019 Chae et al. http://creativecommons.org/licenses/by-nc/3.0/ This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php).
spellingShingle Original Research
Chae, Yun Jeong
Kim, Dae Hee
Park, Eun Jeong
Oh, Juyeon
Yi, In Kyong
A comparison of McGrath MAC, Pentax AWS, and Macintosh direct laryngoscopes for nasotracheal intubation: a randomized controlled trial
title A comparison of McGrath MAC, Pentax AWS, and Macintosh direct laryngoscopes for nasotracheal intubation: a randomized controlled trial
title_full A comparison of McGrath MAC, Pentax AWS, and Macintosh direct laryngoscopes for nasotracheal intubation: a randomized controlled trial
title_fullStr A comparison of McGrath MAC, Pentax AWS, and Macintosh direct laryngoscopes for nasotracheal intubation: a randomized controlled trial
title_full_unstemmed A comparison of McGrath MAC, Pentax AWS, and Macintosh direct laryngoscopes for nasotracheal intubation: a randomized controlled trial
title_short A comparison of McGrath MAC, Pentax AWS, and Macintosh direct laryngoscopes for nasotracheal intubation: a randomized controlled trial
title_sort comparison of mcgrath mac, pentax aws, and macintosh direct laryngoscopes for nasotracheal intubation: a randomized controlled trial
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6756366/
https://www.ncbi.nlm.nih.gov/pubmed/31571890
http://dx.doi.org/10.2147/TCRM.S220451
work_keys_str_mv AT chaeyunjeong acomparisonofmcgrathmacpentaxawsandmacintoshdirectlaryngoscopesfornasotrachealintubationarandomizedcontrolledtrial
AT kimdaehee acomparisonofmcgrathmacpentaxawsandmacintoshdirectlaryngoscopesfornasotrachealintubationarandomizedcontrolledtrial
AT parkeunjeong acomparisonofmcgrathmacpentaxawsandmacintoshdirectlaryngoscopesfornasotrachealintubationarandomizedcontrolledtrial
AT ohjuyeon acomparisonofmcgrathmacpentaxawsandmacintoshdirectlaryngoscopesfornasotrachealintubationarandomizedcontrolledtrial
AT yiinkyong acomparisonofmcgrathmacpentaxawsandmacintoshdirectlaryngoscopesfornasotrachealintubationarandomizedcontrolledtrial
AT chaeyunjeong comparisonofmcgrathmacpentaxawsandmacintoshdirectlaryngoscopesfornasotrachealintubationarandomizedcontrolledtrial
AT kimdaehee comparisonofmcgrathmacpentaxawsandmacintoshdirectlaryngoscopesfornasotrachealintubationarandomizedcontrolledtrial
AT parkeunjeong comparisonofmcgrathmacpentaxawsandmacintoshdirectlaryngoscopesfornasotrachealintubationarandomizedcontrolledtrial
AT ohjuyeon comparisonofmcgrathmacpentaxawsandmacintoshdirectlaryngoscopesfornasotrachealintubationarandomizedcontrolledtrial
AT yiinkyong comparisonofmcgrathmacpentaxawsandmacintoshdirectlaryngoscopesfornasotrachealintubationarandomizedcontrolledtrial