Cargando…
A comparison of McGrath MAC, Pentax AWS, and Macintosh direct laryngoscopes for nasotracheal intubation: a randomized controlled trial
PURPOSE: Videolaryngoscopy in nasotracheal intubation has been reported to be better than direct laryngoscopy. The most suitable type of videolaryngoscope remains unknown. This study aimed to compare two videolaryngoscopes (McGrath MAC and Pentax AWS) with a Macintosh laryngoscope during nasotrachea...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6756366/ https://www.ncbi.nlm.nih.gov/pubmed/31571890 http://dx.doi.org/10.2147/TCRM.S220451 |
_version_ | 1783453385219899392 |
---|---|
author | Chae, Yun Jeong Kim, Dae Hee Park, Eun Jeong Oh, Juyeon Yi, In Kyong |
author_facet | Chae, Yun Jeong Kim, Dae Hee Park, Eun Jeong Oh, Juyeon Yi, In Kyong |
author_sort | Chae, Yun Jeong |
collection | PubMed |
description | PURPOSE: Videolaryngoscopy in nasotracheal intubation has been reported to be better than direct laryngoscopy. The most suitable type of videolaryngoscope remains unknown. This study aimed to compare two videolaryngoscopes (McGrath MAC and Pentax AWS) with a Macintosh laryngoscope during nasotracheal intubation. METHODS: Overall, 123 patients older than 18 with normal airways who needed nasotracheal intubation were randomly allocated into three groups: Macintosh (n=41), McGrath (n=41), and Pentax (n=41). Intubation time was the primary outcome and subdivided into three steps: nose to oropharynx, oropharynx to laryngeal inlet, and laryngeal inlet to trachea. Time required, ease of each step, glottic view grade, modified nasal intubation–difficulty score, and subjective difficulty were evaluated. RESULTS: Intubation time among the three groups was not significantly different (Macintosh 34.6±8.1 seconds, McGrath 35.2±7.9 seconds, Pentax 36.2±9.7 seconds; p=0.727). While the glottal view was better with videolaryngoscopes (I/IIa/IIb/III 36.6%/36.6%/19.5%/7.3% vs 82.9%/9.8%/7.3%/0%, vs 63.4%/29.3%/4.9%/2.4%, p=0.000), modified nasal intubation–difficulty score and subjective difficulty and ease of each step were not significantly different. However, the Pentax took longest for the second step (11.8±6.3 vs 10.3±3.5 vs 15.1±7.6 seconds, p=0.001) but was shortest for the third step (2.9±2.6 vs 4.4±5.6 vs 1.7±0.7 seconds, p=0.001). CONCLUSION: The McGrath MAC and Pentax AWS showed no benefits in intubation time or difficulty, despite better glottal views, compared to the Macintosh laryngoscope in nasotracheal intubation. Additionally, videolaryngoscopes had variable performance at different steps of nasotracheal intubation. |
format | Online Article Text |
id | pubmed-6756366 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Dove |
record_format | MEDLINE/PubMed |
spelling | pubmed-67563662019-09-30 A comparison of McGrath MAC, Pentax AWS, and Macintosh direct laryngoscopes for nasotracheal intubation: a randomized controlled trial Chae, Yun Jeong Kim, Dae Hee Park, Eun Jeong Oh, Juyeon Yi, In Kyong Ther Clin Risk Manag Original Research PURPOSE: Videolaryngoscopy in nasotracheal intubation has been reported to be better than direct laryngoscopy. The most suitable type of videolaryngoscope remains unknown. This study aimed to compare two videolaryngoscopes (McGrath MAC and Pentax AWS) with a Macintosh laryngoscope during nasotracheal intubation. METHODS: Overall, 123 patients older than 18 with normal airways who needed nasotracheal intubation were randomly allocated into three groups: Macintosh (n=41), McGrath (n=41), and Pentax (n=41). Intubation time was the primary outcome and subdivided into three steps: nose to oropharynx, oropharynx to laryngeal inlet, and laryngeal inlet to trachea. Time required, ease of each step, glottic view grade, modified nasal intubation–difficulty score, and subjective difficulty were evaluated. RESULTS: Intubation time among the three groups was not significantly different (Macintosh 34.6±8.1 seconds, McGrath 35.2±7.9 seconds, Pentax 36.2±9.7 seconds; p=0.727). While the glottal view was better with videolaryngoscopes (I/IIa/IIb/III 36.6%/36.6%/19.5%/7.3% vs 82.9%/9.8%/7.3%/0%, vs 63.4%/29.3%/4.9%/2.4%, p=0.000), modified nasal intubation–difficulty score and subjective difficulty and ease of each step were not significantly different. However, the Pentax took longest for the second step (11.8±6.3 vs 10.3±3.5 vs 15.1±7.6 seconds, p=0.001) but was shortest for the third step (2.9±2.6 vs 4.4±5.6 vs 1.7±0.7 seconds, p=0.001). CONCLUSION: The McGrath MAC and Pentax AWS showed no benefits in intubation time or difficulty, despite better glottal views, compared to the Macintosh laryngoscope in nasotracheal intubation. Additionally, videolaryngoscopes had variable performance at different steps of nasotracheal intubation. Dove 2019-09-18 /pmc/articles/PMC6756366/ /pubmed/31571890 http://dx.doi.org/10.2147/TCRM.S220451 Text en © 2019 Chae et al. http://creativecommons.org/licenses/by-nc/3.0/ This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php). |
spellingShingle | Original Research Chae, Yun Jeong Kim, Dae Hee Park, Eun Jeong Oh, Juyeon Yi, In Kyong A comparison of McGrath MAC, Pentax AWS, and Macintosh direct laryngoscopes for nasotracheal intubation: a randomized controlled trial |
title | A comparison of McGrath MAC, Pentax AWS, and Macintosh direct laryngoscopes for nasotracheal intubation: a randomized controlled trial |
title_full | A comparison of McGrath MAC, Pentax AWS, and Macintosh direct laryngoscopes for nasotracheal intubation: a randomized controlled trial |
title_fullStr | A comparison of McGrath MAC, Pentax AWS, and Macintosh direct laryngoscopes for nasotracheal intubation: a randomized controlled trial |
title_full_unstemmed | A comparison of McGrath MAC, Pentax AWS, and Macintosh direct laryngoscopes for nasotracheal intubation: a randomized controlled trial |
title_short | A comparison of McGrath MAC, Pentax AWS, and Macintosh direct laryngoscopes for nasotracheal intubation: a randomized controlled trial |
title_sort | comparison of mcgrath mac, pentax aws, and macintosh direct laryngoscopes for nasotracheal intubation: a randomized controlled trial |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6756366/ https://www.ncbi.nlm.nih.gov/pubmed/31571890 http://dx.doi.org/10.2147/TCRM.S220451 |
work_keys_str_mv | AT chaeyunjeong acomparisonofmcgrathmacpentaxawsandmacintoshdirectlaryngoscopesfornasotrachealintubationarandomizedcontrolledtrial AT kimdaehee acomparisonofmcgrathmacpentaxawsandmacintoshdirectlaryngoscopesfornasotrachealintubationarandomizedcontrolledtrial AT parkeunjeong acomparisonofmcgrathmacpentaxawsandmacintoshdirectlaryngoscopesfornasotrachealintubationarandomizedcontrolledtrial AT ohjuyeon acomparisonofmcgrathmacpentaxawsandmacintoshdirectlaryngoscopesfornasotrachealintubationarandomizedcontrolledtrial AT yiinkyong acomparisonofmcgrathmacpentaxawsandmacintoshdirectlaryngoscopesfornasotrachealintubationarandomizedcontrolledtrial AT chaeyunjeong comparisonofmcgrathmacpentaxawsandmacintoshdirectlaryngoscopesfornasotrachealintubationarandomizedcontrolledtrial AT kimdaehee comparisonofmcgrathmacpentaxawsandmacintoshdirectlaryngoscopesfornasotrachealintubationarandomizedcontrolledtrial AT parkeunjeong comparisonofmcgrathmacpentaxawsandmacintoshdirectlaryngoscopesfornasotrachealintubationarandomizedcontrolledtrial AT ohjuyeon comparisonofmcgrathmacpentaxawsandmacintoshdirectlaryngoscopesfornasotrachealintubationarandomizedcontrolledtrial AT yiinkyong comparisonofmcgrathmacpentaxawsandmacintoshdirectlaryngoscopesfornasotrachealintubationarandomizedcontrolledtrial |