Cargando…

Development and validation of image quality scoring criteria (IQSC) for pediatric CT: a preliminary study

OBJECTIVE: To develop and assess the value and limitations of an image quality scoring criteria (IQSC) for pediatric CT exams. METHODS: IQSC was developed for subjective assessment of image quality using the scoring scale from 0 to 4, with 0 indicating desired anatomy or features not seen, 3 for ade...

Descripción completa

Detalles Bibliográficos
Autores principales: Padole, Atul M., Sagar, Pallavi, Westra, Sjirk J., Lim, Ruth, Nimkin, Katherine, Kalra, Mannudeep K., Gee, Michael S., Rehani, Madan M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6757090/
https://www.ncbi.nlm.nih.gov/pubmed/31549234
http://dx.doi.org/10.1186/s13244-019-0769-8
_version_ 1783453514156998656
author Padole, Atul M.
Sagar, Pallavi
Westra, Sjirk J.
Lim, Ruth
Nimkin, Katherine
Kalra, Mannudeep K.
Gee, Michael S.
Rehani, Madan M.
author_facet Padole, Atul M.
Sagar, Pallavi
Westra, Sjirk J.
Lim, Ruth
Nimkin, Katherine
Kalra, Mannudeep K.
Gee, Michael S.
Rehani, Madan M.
author_sort Padole, Atul M.
collection PubMed
description OBJECTIVE: To develop and assess the value and limitations of an image quality scoring criteria (IQSC) for pediatric CT exams. METHODS: IQSC was developed for subjective assessment of image quality using the scoring scale from 0 to 4, with 0 indicating desired anatomy or features not seen, 3 for adequate image quality, and 4 depicting higher than needed image quality. Pediatric CT examinations from 30 separate patients were selected, five each for routine chest, routine abdomen, kidney stone, appendicitis, craniosynostosis, and ventriculoperitoneal (VP) shunt. Five board-certified pediatric radiologists independently performed image quality evaluation using the proposed IQSC. The kappa statistics were used to assess the interobserver variability. RESULTS: All five radiologists gave a score of 3 to two-third (67%) of all CT exams, followed by a score of 4 for 29% of CT exams, and 2 for 4% exams. The median image quality scores for all exams were 3 and the interobserver agreement among five readers (acceptable image quality [scores 3 or 4] vs sub-optimal image quality ([scores 1 and 2]) was moderate to very good (kappa 0.4–1). For all five radiologists, the lesion detection was adequate for all CT exams. CONCLUSIONS: The image quality scoring criteria covering routine and some clinical indication-based imaging scenarios for pediatric CT examinations has potential to offer a simple and practical tool for assessing image quality with a reasonable degree of interobserver agreement. A more extensive and multi-centric study is recommended to establish wider usefulness of these criteria. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s13244-019-0769-8) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-6757090
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-67570902019-10-07 Development and validation of image quality scoring criteria (IQSC) for pediatric CT: a preliminary study Padole, Atul M. Sagar, Pallavi Westra, Sjirk J. Lim, Ruth Nimkin, Katherine Kalra, Mannudeep K. Gee, Michael S. Rehani, Madan M. Insights Imaging Original Article OBJECTIVE: To develop and assess the value and limitations of an image quality scoring criteria (IQSC) for pediatric CT exams. METHODS: IQSC was developed for subjective assessment of image quality using the scoring scale from 0 to 4, with 0 indicating desired anatomy or features not seen, 3 for adequate image quality, and 4 depicting higher than needed image quality. Pediatric CT examinations from 30 separate patients were selected, five each for routine chest, routine abdomen, kidney stone, appendicitis, craniosynostosis, and ventriculoperitoneal (VP) shunt. Five board-certified pediatric radiologists independently performed image quality evaluation using the proposed IQSC. The kappa statistics were used to assess the interobserver variability. RESULTS: All five radiologists gave a score of 3 to two-third (67%) of all CT exams, followed by a score of 4 for 29% of CT exams, and 2 for 4% exams. The median image quality scores for all exams were 3 and the interobserver agreement among five readers (acceptable image quality [scores 3 or 4] vs sub-optimal image quality ([scores 1 and 2]) was moderate to very good (kappa 0.4–1). For all five radiologists, the lesion detection was adequate for all CT exams. CONCLUSIONS: The image quality scoring criteria covering routine and some clinical indication-based imaging scenarios for pediatric CT examinations has potential to offer a simple and practical tool for assessing image quality with a reasonable degree of interobserver agreement. A more extensive and multi-centric study is recommended to establish wider usefulness of these criteria. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s13244-019-0769-8) contains supplementary material, which is available to authorized users. Springer Berlin Heidelberg 2019-09-23 /pmc/articles/PMC6757090/ /pubmed/31549234 http://dx.doi.org/10.1186/s13244-019-0769-8 Text en © The Author(s). 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Original Article
Padole, Atul M.
Sagar, Pallavi
Westra, Sjirk J.
Lim, Ruth
Nimkin, Katherine
Kalra, Mannudeep K.
Gee, Michael S.
Rehani, Madan M.
Development and validation of image quality scoring criteria (IQSC) for pediatric CT: a preliminary study
title Development and validation of image quality scoring criteria (IQSC) for pediatric CT: a preliminary study
title_full Development and validation of image quality scoring criteria (IQSC) for pediatric CT: a preliminary study
title_fullStr Development and validation of image quality scoring criteria (IQSC) for pediatric CT: a preliminary study
title_full_unstemmed Development and validation of image quality scoring criteria (IQSC) for pediatric CT: a preliminary study
title_short Development and validation of image quality scoring criteria (IQSC) for pediatric CT: a preliminary study
title_sort development and validation of image quality scoring criteria (iqsc) for pediatric ct: a preliminary study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6757090/
https://www.ncbi.nlm.nih.gov/pubmed/31549234
http://dx.doi.org/10.1186/s13244-019-0769-8
work_keys_str_mv AT padoleatulm developmentandvalidationofimagequalityscoringcriteriaiqscforpediatricctapreliminarystudy
AT sagarpallavi developmentandvalidationofimagequalityscoringcriteriaiqscforpediatricctapreliminarystudy
AT westrasjirkj developmentandvalidationofimagequalityscoringcriteriaiqscforpediatricctapreliminarystudy
AT limruth developmentandvalidationofimagequalityscoringcriteriaiqscforpediatricctapreliminarystudy
AT nimkinkatherine developmentandvalidationofimagequalityscoringcriteriaiqscforpediatricctapreliminarystudy
AT kalramannudeepk developmentandvalidationofimagequalityscoringcriteriaiqscforpediatricctapreliminarystudy
AT geemichaels developmentandvalidationofimagequalityscoringcriteriaiqscforpediatricctapreliminarystudy
AT rehanimadanm developmentandvalidationofimagequalityscoringcriteriaiqscforpediatricctapreliminarystudy