Cargando…
Development and validation of image quality scoring criteria (IQSC) for pediatric CT: a preliminary study
OBJECTIVE: To develop and assess the value and limitations of an image quality scoring criteria (IQSC) for pediatric CT exams. METHODS: IQSC was developed for subjective assessment of image quality using the scoring scale from 0 to 4, with 0 indicating desired anatomy or features not seen, 3 for ade...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6757090/ https://www.ncbi.nlm.nih.gov/pubmed/31549234 http://dx.doi.org/10.1186/s13244-019-0769-8 |
_version_ | 1783453514156998656 |
---|---|
author | Padole, Atul M. Sagar, Pallavi Westra, Sjirk J. Lim, Ruth Nimkin, Katherine Kalra, Mannudeep K. Gee, Michael S. Rehani, Madan M. |
author_facet | Padole, Atul M. Sagar, Pallavi Westra, Sjirk J. Lim, Ruth Nimkin, Katherine Kalra, Mannudeep K. Gee, Michael S. Rehani, Madan M. |
author_sort | Padole, Atul M. |
collection | PubMed |
description | OBJECTIVE: To develop and assess the value and limitations of an image quality scoring criteria (IQSC) for pediatric CT exams. METHODS: IQSC was developed for subjective assessment of image quality using the scoring scale from 0 to 4, with 0 indicating desired anatomy or features not seen, 3 for adequate image quality, and 4 depicting higher than needed image quality. Pediatric CT examinations from 30 separate patients were selected, five each for routine chest, routine abdomen, kidney stone, appendicitis, craniosynostosis, and ventriculoperitoneal (VP) shunt. Five board-certified pediatric radiologists independently performed image quality evaluation using the proposed IQSC. The kappa statistics were used to assess the interobserver variability. RESULTS: All five radiologists gave a score of 3 to two-third (67%) of all CT exams, followed by a score of 4 for 29% of CT exams, and 2 for 4% exams. The median image quality scores for all exams were 3 and the interobserver agreement among five readers (acceptable image quality [scores 3 or 4] vs sub-optimal image quality ([scores 1 and 2]) was moderate to very good (kappa 0.4–1). For all five radiologists, the lesion detection was adequate for all CT exams. CONCLUSIONS: The image quality scoring criteria covering routine and some clinical indication-based imaging scenarios for pediatric CT examinations has potential to offer a simple and practical tool for assessing image quality with a reasonable degree of interobserver agreement. A more extensive and multi-centric study is recommended to establish wider usefulness of these criteria. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s13244-019-0769-8) contains supplementary material, which is available to authorized users. |
format | Online Article Text |
id | pubmed-6757090 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-67570902019-10-07 Development and validation of image quality scoring criteria (IQSC) for pediatric CT: a preliminary study Padole, Atul M. Sagar, Pallavi Westra, Sjirk J. Lim, Ruth Nimkin, Katherine Kalra, Mannudeep K. Gee, Michael S. Rehani, Madan M. Insights Imaging Original Article OBJECTIVE: To develop and assess the value and limitations of an image quality scoring criteria (IQSC) for pediatric CT exams. METHODS: IQSC was developed for subjective assessment of image quality using the scoring scale from 0 to 4, with 0 indicating desired anatomy or features not seen, 3 for adequate image quality, and 4 depicting higher than needed image quality. Pediatric CT examinations from 30 separate patients were selected, five each for routine chest, routine abdomen, kidney stone, appendicitis, craniosynostosis, and ventriculoperitoneal (VP) shunt. Five board-certified pediatric radiologists independently performed image quality evaluation using the proposed IQSC. The kappa statistics were used to assess the interobserver variability. RESULTS: All five radiologists gave a score of 3 to two-third (67%) of all CT exams, followed by a score of 4 for 29% of CT exams, and 2 for 4% exams. The median image quality scores for all exams were 3 and the interobserver agreement among five readers (acceptable image quality [scores 3 or 4] vs sub-optimal image quality ([scores 1 and 2]) was moderate to very good (kappa 0.4–1). For all five radiologists, the lesion detection was adequate for all CT exams. CONCLUSIONS: The image quality scoring criteria covering routine and some clinical indication-based imaging scenarios for pediatric CT examinations has potential to offer a simple and practical tool for assessing image quality with a reasonable degree of interobserver agreement. A more extensive and multi-centric study is recommended to establish wider usefulness of these criteria. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s13244-019-0769-8) contains supplementary material, which is available to authorized users. Springer Berlin Heidelberg 2019-09-23 /pmc/articles/PMC6757090/ /pubmed/31549234 http://dx.doi.org/10.1186/s13244-019-0769-8 Text en © The Author(s). 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Original Article Padole, Atul M. Sagar, Pallavi Westra, Sjirk J. Lim, Ruth Nimkin, Katherine Kalra, Mannudeep K. Gee, Michael S. Rehani, Madan M. Development and validation of image quality scoring criteria (IQSC) for pediatric CT: a preliminary study |
title | Development and validation of image quality scoring criteria (IQSC) for pediatric CT: a preliminary study |
title_full | Development and validation of image quality scoring criteria (IQSC) for pediatric CT: a preliminary study |
title_fullStr | Development and validation of image quality scoring criteria (IQSC) for pediatric CT: a preliminary study |
title_full_unstemmed | Development and validation of image quality scoring criteria (IQSC) for pediatric CT: a preliminary study |
title_short | Development and validation of image quality scoring criteria (IQSC) for pediatric CT: a preliminary study |
title_sort | development and validation of image quality scoring criteria (iqsc) for pediatric ct: a preliminary study |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6757090/ https://www.ncbi.nlm.nih.gov/pubmed/31549234 http://dx.doi.org/10.1186/s13244-019-0769-8 |
work_keys_str_mv | AT padoleatulm developmentandvalidationofimagequalityscoringcriteriaiqscforpediatricctapreliminarystudy AT sagarpallavi developmentandvalidationofimagequalityscoringcriteriaiqscforpediatricctapreliminarystudy AT westrasjirkj developmentandvalidationofimagequalityscoringcriteriaiqscforpediatricctapreliminarystudy AT limruth developmentandvalidationofimagequalityscoringcriteriaiqscforpediatricctapreliminarystudy AT nimkinkatherine developmentandvalidationofimagequalityscoringcriteriaiqscforpediatricctapreliminarystudy AT kalramannudeepk developmentandvalidationofimagequalityscoringcriteriaiqscforpediatricctapreliminarystudy AT geemichaels developmentandvalidationofimagequalityscoringcriteriaiqscforpediatricctapreliminarystudy AT rehanimadanm developmentandvalidationofimagequalityscoringcriteriaiqscforpediatricctapreliminarystudy |