Cargando…
Refractory Myopic Retinal Detachment and Macular Hole Closure with Autologous Neurosensory Retinal Free Flap
The purpose of this case report is to describe a modified technique involving the use of an autologous neurosensory retinal free flap for closure of a macular hole (MH) during retinal detachment (RD) surgery. A 50-year-old female presented with sudden vision loss (light perception only) and a recurr...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
S. Karger AG
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6760359/ https://www.ncbi.nlm.nih.gov/pubmed/31692566 http://dx.doi.org/10.1159/000500275 |
_version_ | 1783453851645378560 |
---|---|
author | Sousa Neves, Filipe Braga, Joana Sepúlveda, Paula Bilhoto, Miguel |
author_facet | Sousa Neves, Filipe Braga, Joana Sepúlveda, Paula Bilhoto, Miguel |
author_sort | Sousa Neves, Filipe |
collection | PubMed |
description | The purpose of this case report is to describe a modified technique involving the use of an autologous neurosensory retinal free flap for closure of a macular hole (MH) during retinal detachment (RD) surgery. A 50-year-old female presented with sudden vision loss (light perception only) and a recurrent myopic RD associated with an MH. An autologous neurosensory retinal free flap was obtained and moved toward the MH. Silicone oil was used as an endotamponade and removed after 6 months. Two months after oil removal visual acuity improved to 20/400 and remained stable thereafter; however, the patient developed central retinal atrophy. One year after surgery the MH was closed and the retina attached. This modified technique with the use of an autologous neurosensory retinal flap provides an alternative approach for recurrent MH in RD procedures. |
format | Online Article Text |
id | pubmed-6760359 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | S. Karger AG |
record_format | MEDLINE/PubMed |
spelling | pubmed-67603592019-11-05 Refractory Myopic Retinal Detachment and Macular Hole Closure with Autologous Neurosensory Retinal Free Flap Sousa Neves, Filipe Braga, Joana Sepúlveda, Paula Bilhoto, Miguel Case Rep Ophthalmol Case Report The purpose of this case report is to describe a modified technique involving the use of an autologous neurosensory retinal free flap for closure of a macular hole (MH) during retinal detachment (RD) surgery. A 50-year-old female presented with sudden vision loss (light perception only) and a recurrent myopic RD associated with an MH. An autologous neurosensory retinal free flap was obtained and moved toward the MH. Silicone oil was used as an endotamponade and removed after 6 months. Two months after oil removal visual acuity improved to 20/400 and remained stable thereafter; however, the patient developed central retinal atrophy. One year after surgery the MH was closed and the retina attached. This modified technique with the use of an autologous neurosensory retinal flap provides an alternative approach for recurrent MH in RD procedures. S. Karger AG 2019-05-23 /pmc/articles/PMC6760359/ /pubmed/31692566 http://dx.doi.org/10.1159/000500275 Text en Copyright © 2019 by S. Karger AG, Basel http://creativecommons.org/licenses/by-nc/4.0/ This article is licensed under the Creative Commons Attribution-NonCommercial-4.0 International License (CC BY-NC) (http://www.karger.com/Services/OpenAccessLicense). Usage and distribution for commercial purposes requires written permission. |
spellingShingle | Case Report Sousa Neves, Filipe Braga, Joana Sepúlveda, Paula Bilhoto, Miguel Refractory Myopic Retinal Detachment and Macular Hole Closure with Autologous Neurosensory Retinal Free Flap |
title | Refractory Myopic Retinal Detachment and Macular Hole Closure with Autologous Neurosensory Retinal Free Flap |
title_full | Refractory Myopic Retinal Detachment and Macular Hole Closure with Autologous Neurosensory Retinal Free Flap |
title_fullStr | Refractory Myopic Retinal Detachment and Macular Hole Closure with Autologous Neurosensory Retinal Free Flap |
title_full_unstemmed | Refractory Myopic Retinal Detachment and Macular Hole Closure with Autologous Neurosensory Retinal Free Flap |
title_short | Refractory Myopic Retinal Detachment and Macular Hole Closure with Autologous Neurosensory Retinal Free Flap |
title_sort | refractory myopic retinal detachment and macular hole closure with autologous neurosensory retinal free flap |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6760359/ https://www.ncbi.nlm.nih.gov/pubmed/31692566 http://dx.doi.org/10.1159/000500275 |
work_keys_str_mv | AT sousanevesfilipe refractorymyopicretinaldetachmentandmacularholeclosurewithautologousneurosensoryretinalfreeflap AT bragajoana refractorymyopicretinaldetachmentandmacularholeclosurewithautologousneurosensoryretinalfreeflap AT sepulvedapaula refractorymyopicretinaldetachmentandmacularholeclosurewithautologousneurosensoryretinalfreeflap AT bilhotomiguel refractorymyopicretinaldetachmentandmacularholeclosurewithautologousneurosensoryretinalfreeflap |