Cargando…

Measurement of Glomerular Filtration Rate Using Multiphasic Computed Tomography in Patients With Unilateral Renal Tumors: A Feasibility Study

OBJECTIVES: This study was to assess the feasibility of a modified multiphasic CT scan protocol combined with homemade software measurements of glomerular filtration rate (CT-GFR) and explore the effect of renal tumor volume on the calculation of CT-GFR. MATERIALS AND METHODS: Prospective observatio...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Tingting, Xu, Yi, Liu, Wangyan, Shao, Pengfei, Lv, Qiang, Yang, Guanyu, Tang, Lijun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6761270/
https://www.ncbi.nlm.nih.gov/pubmed/31607949
http://dx.doi.org/10.3389/fphys.2019.01209
_version_ 1783453993151758336
author Wang, Tingting
Xu, Yi
Liu, Wangyan
Shao, Pengfei
Lv, Qiang
Yang, Guanyu
Tang, Lijun
author_facet Wang, Tingting
Xu, Yi
Liu, Wangyan
Shao, Pengfei
Lv, Qiang
Yang, Guanyu
Tang, Lijun
author_sort Wang, Tingting
collection PubMed
description OBJECTIVES: This study was to assess the feasibility of a modified multiphasic CT scan protocol combined with homemade software measurements of glomerular filtration rate (CT-GFR) and explore the effect of renal tumor volume on the calculation of CT-GFR. MATERIALS AND METHODS: Prospective observational study comparing three methods of GFR measurement from February 2017 to December 2017, 91 patients with unilateral renal tumor underwent both a modified multiphasic CT scans of kidney and serum creatinine (Scr) tests preoperatively, of which 15 cases underwent additional radionuclide examination. Total and split CT-GFR, with or without renal tumor, were quantified by the homemade software in early and late renal parenchymal phases, respectively. The volume of renal tumor was quantified by the homemade software. Correlation and difference between CT-GFR and traditional methods of GFR measurement, including estimated GFR (eGFR) from Scr concentration and split GFR using of radionuclide examination (R-GFR), were performed. RESULTS: There is a strong correlation between CT-GFR with renal tumor and eGFR (r = 0.90, p < 0.001) in early renal parenchymal phase. The relative CT-GFR in early renal parenchymal phase was highly correlated with the relative R-GFR (r = 0.88, p < 0.001). Renal tumor volume significantly correlated with the value of CT-GFR that determined by subtracting the CT-GFR measurement without renal tumor from CT-GFR measurement with renal tumor (r = 0.89, p < 0.001). CONCLUSION: A modified multiphasic CT scan protocol combined with homemade software might be an alternative technique for the evaluation of renal function for the patients with unilateral renal tumor.
format Online
Article
Text
id pubmed-6761270
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-67612702019-10-13 Measurement of Glomerular Filtration Rate Using Multiphasic Computed Tomography in Patients With Unilateral Renal Tumors: A Feasibility Study Wang, Tingting Xu, Yi Liu, Wangyan Shao, Pengfei Lv, Qiang Yang, Guanyu Tang, Lijun Front Physiol Physiology OBJECTIVES: This study was to assess the feasibility of a modified multiphasic CT scan protocol combined with homemade software measurements of glomerular filtration rate (CT-GFR) and explore the effect of renal tumor volume on the calculation of CT-GFR. MATERIALS AND METHODS: Prospective observational study comparing three methods of GFR measurement from February 2017 to December 2017, 91 patients with unilateral renal tumor underwent both a modified multiphasic CT scans of kidney and serum creatinine (Scr) tests preoperatively, of which 15 cases underwent additional radionuclide examination. Total and split CT-GFR, with or without renal tumor, were quantified by the homemade software in early and late renal parenchymal phases, respectively. The volume of renal tumor was quantified by the homemade software. Correlation and difference between CT-GFR and traditional methods of GFR measurement, including estimated GFR (eGFR) from Scr concentration and split GFR using of radionuclide examination (R-GFR), were performed. RESULTS: There is a strong correlation between CT-GFR with renal tumor and eGFR (r = 0.90, p < 0.001) in early renal parenchymal phase. The relative CT-GFR in early renal parenchymal phase was highly correlated with the relative R-GFR (r = 0.88, p < 0.001). Renal tumor volume significantly correlated with the value of CT-GFR that determined by subtracting the CT-GFR measurement without renal tumor from CT-GFR measurement with renal tumor (r = 0.89, p < 0.001). CONCLUSION: A modified multiphasic CT scan protocol combined with homemade software might be an alternative technique for the evaluation of renal function for the patients with unilateral renal tumor. Frontiers Media S.A. 2019-09-19 /pmc/articles/PMC6761270/ /pubmed/31607949 http://dx.doi.org/10.3389/fphys.2019.01209 Text en Copyright © 2019 Wang, Xu, Liu, Shao, Lv, Yang and Tang. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Physiology
Wang, Tingting
Xu, Yi
Liu, Wangyan
Shao, Pengfei
Lv, Qiang
Yang, Guanyu
Tang, Lijun
Measurement of Glomerular Filtration Rate Using Multiphasic Computed Tomography in Patients With Unilateral Renal Tumors: A Feasibility Study
title Measurement of Glomerular Filtration Rate Using Multiphasic Computed Tomography in Patients With Unilateral Renal Tumors: A Feasibility Study
title_full Measurement of Glomerular Filtration Rate Using Multiphasic Computed Tomography in Patients With Unilateral Renal Tumors: A Feasibility Study
title_fullStr Measurement of Glomerular Filtration Rate Using Multiphasic Computed Tomography in Patients With Unilateral Renal Tumors: A Feasibility Study
title_full_unstemmed Measurement of Glomerular Filtration Rate Using Multiphasic Computed Tomography in Patients With Unilateral Renal Tumors: A Feasibility Study
title_short Measurement of Glomerular Filtration Rate Using Multiphasic Computed Tomography in Patients With Unilateral Renal Tumors: A Feasibility Study
title_sort measurement of glomerular filtration rate using multiphasic computed tomography in patients with unilateral renal tumors: a feasibility study
topic Physiology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6761270/
https://www.ncbi.nlm.nih.gov/pubmed/31607949
http://dx.doi.org/10.3389/fphys.2019.01209
work_keys_str_mv AT wangtingting measurementofglomerularfiltrationrateusingmultiphasiccomputedtomographyinpatientswithunilateralrenaltumorsafeasibilitystudy
AT xuyi measurementofglomerularfiltrationrateusingmultiphasiccomputedtomographyinpatientswithunilateralrenaltumorsafeasibilitystudy
AT liuwangyan measurementofglomerularfiltrationrateusingmultiphasiccomputedtomographyinpatientswithunilateralrenaltumorsafeasibilitystudy
AT shaopengfei measurementofglomerularfiltrationrateusingmultiphasiccomputedtomographyinpatientswithunilateralrenaltumorsafeasibilitystudy
AT lvqiang measurementofglomerularfiltrationrateusingmultiphasiccomputedtomographyinpatientswithunilateralrenaltumorsafeasibilitystudy
AT yangguanyu measurementofglomerularfiltrationrateusingmultiphasiccomputedtomographyinpatientswithunilateralrenaltumorsafeasibilitystudy
AT tanglijun measurementofglomerularfiltrationrateusingmultiphasiccomputedtomographyinpatientswithunilateralrenaltumorsafeasibilitystudy