Short- and Long-term Results of Glaucoma Valve Implantation for Aniridia-related Glaucoma: A Case Series and Literature Review

OBJECTIVES: To report the results obtained from glaucoma drainage device (GDD) implantation in patients with aniridia-related glaucoma and to review the literature. MATERIALS AND METHODS: We retrospectively reviewed 6 patients who underwent GDD implantation for glaucoma secondary to congenital aniri...

Descripción completa

Detalles Bibliográficos
Autores principales: Soyugelen Demirok, Gülizar, Ekşioğlu, Ümit, Yakın, Mehmet, Kaderli, Ahmet, Tamer Kaderli, Sema, Örnek, Firdevs
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Galenos Publishing 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6761385/
https://www.ncbi.nlm.nih.gov/pubmed/31486604
http://dx.doi.org/10.4274/tjo.galenos.2019.07348
_version_ 1783454020196630528
author Soyugelen Demirok, Gülizar
Ekşioğlu, Ümit
Yakın, Mehmet
Kaderli, Ahmet
Tamer Kaderli, Sema
Örnek, Firdevs
author_facet Soyugelen Demirok, Gülizar
Ekşioğlu, Ümit
Yakın, Mehmet
Kaderli, Ahmet
Tamer Kaderli, Sema
Örnek, Firdevs
author_sort Soyugelen Demirok, Gülizar
collection PubMed
description OBJECTIVES: To report the results obtained from glaucoma drainage device (GDD) implantation in patients with aniridia-related glaucoma and to review the literature. MATERIALS AND METHODS: We retrospectively reviewed 6 patients who underwent GDD implantation for glaucoma secondary to congenital aniridia between April 2001 and February 2015. Data on age at surgery, gender, laterality, surgeries before GDD implantation, GDD model, concomitant ocular disorders, visual acuity, and intraocular pressure (IOP) values before and at 1 and 12 months after GDD implantation, medications, follow-up period, findings during last visit, complications, and course of disease were collected. RESULTS: Mean age at surgery was 16.00±12.31 years (range 5-37 years). Mean IOP was 33.00±12.11 (range 22-50) mmHg just before the GDD implantation with a mean of 3.5±1.2 medications. Mean IOP 1 month after implantation was 16.33±4.22 (range 12-24) mmHg with a mean of 1.5±0.8 medications; at 12 months, mean IOP was 19.50±4.76 (range 15-26) mmHg with 3.0±0.8 medications. At the last follow-up visit, IOP was 21.16±4.07 (range 16-26) mmHg with a mean of 3.33±0.51 medications. Mean follow-up was 19.16±8.8 (range 12-36) months. Surgical success rates were 83.3%, 66.6%, and 50.0% at 1 month, 12 months, and the last visit, respectively. CONCLUSION: GDD implantation was effective in controlling aniridic glaucoma with a success rate of 83.3% at 1-month follow-up and 66.6% at 1-year follow-up. Therefore, it should be considered as an initial surgical treatment for aniridic glaucoma; the clinician should be alert for concomitant ocular disorders.
format Online
Article
Text
id pubmed-6761385
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Galenos Publishing
record_format MEDLINE/PubMed
spelling pubmed-67613852019-10-02 Short- and Long-term Results of Glaucoma Valve Implantation for Aniridia-related Glaucoma: A Case Series and Literature Review Soyugelen Demirok, Gülizar Ekşioğlu, Ümit Yakın, Mehmet Kaderli, Ahmet Tamer Kaderli, Sema Örnek, Firdevs Turk J Ophthalmol Original Article OBJECTIVES: To report the results obtained from glaucoma drainage device (GDD) implantation in patients with aniridia-related glaucoma and to review the literature. MATERIALS AND METHODS: We retrospectively reviewed 6 patients who underwent GDD implantation for glaucoma secondary to congenital aniridia between April 2001 and February 2015. Data on age at surgery, gender, laterality, surgeries before GDD implantation, GDD model, concomitant ocular disorders, visual acuity, and intraocular pressure (IOP) values before and at 1 and 12 months after GDD implantation, medications, follow-up period, findings during last visit, complications, and course of disease were collected. RESULTS: Mean age at surgery was 16.00±12.31 years (range 5-37 years). Mean IOP was 33.00±12.11 (range 22-50) mmHg just before the GDD implantation with a mean of 3.5±1.2 medications. Mean IOP 1 month after implantation was 16.33±4.22 (range 12-24) mmHg with a mean of 1.5±0.8 medications; at 12 months, mean IOP was 19.50±4.76 (range 15-26) mmHg with 3.0±0.8 medications. At the last follow-up visit, IOP was 21.16±4.07 (range 16-26) mmHg with a mean of 3.33±0.51 medications. Mean follow-up was 19.16±8.8 (range 12-36) months. Surgical success rates were 83.3%, 66.6%, and 50.0% at 1 month, 12 months, and the last visit, respectively. CONCLUSION: GDD implantation was effective in controlling aniridic glaucoma with a success rate of 83.3% at 1-month follow-up and 66.6% at 1-year follow-up. Therefore, it should be considered as an initial surgical treatment for aniridic glaucoma; the clinician should be alert for concomitant ocular disorders. Galenos Publishing 2019-08 2019-09-03 /pmc/articles/PMC6761385/ /pubmed/31486604 http://dx.doi.org/10.4274/tjo.galenos.2019.07348 Text en © Copyright 2019 by Turkish Ophthalmological Association | Turkish Journal of Ophthalmology, published by Galenos Publishing House. http://creativecommons.org/licenses/by/2.5/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Soyugelen Demirok, Gülizar
Ekşioğlu, Ümit
Yakın, Mehmet
Kaderli, Ahmet
Tamer Kaderli, Sema
Örnek, Firdevs
Short- and Long-term Results of Glaucoma Valve Implantation for Aniridia-related Glaucoma: A Case Series and Literature Review
title Short- and Long-term Results of Glaucoma Valve Implantation for Aniridia-related Glaucoma: A Case Series and Literature Review
title_full Short- and Long-term Results of Glaucoma Valve Implantation for Aniridia-related Glaucoma: A Case Series and Literature Review
title_fullStr Short- and Long-term Results of Glaucoma Valve Implantation for Aniridia-related Glaucoma: A Case Series and Literature Review
title_full_unstemmed Short- and Long-term Results of Glaucoma Valve Implantation for Aniridia-related Glaucoma: A Case Series and Literature Review
title_short Short- and Long-term Results of Glaucoma Valve Implantation for Aniridia-related Glaucoma: A Case Series and Literature Review
title_sort short- and long-term results of glaucoma valve implantation for aniridia-related glaucoma: a case series and literature review
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6761385/
https://www.ncbi.nlm.nih.gov/pubmed/31486604
http://dx.doi.org/10.4274/tjo.galenos.2019.07348
work_keys_str_mv AT soyugelendemirokgulizar shortandlongtermresultsofglaucomavalveimplantationforaniridiarelatedglaucomaacaseseriesandliteraturereview
AT eksiogluumit shortandlongtermresultsofglaucomavalveimplantationforaniridiarelatedglaucomaacaseseriesandliteraturereview
AT yakınmehmet shortandlongtermresultsofglaucomavalveimplantationforaniridiarelatedglaucomaacaseseriesandliteraturereview
AT kaderliahmet shortandlongtermresultsofglaucomavalveimplantationforaniridiarelatedglaucomaacaseseriesandliteraturereview
AT tamerkaderlisema shortandlongtermresultsofglaucomavalveimplantationforaniridiarelatedglaucomaacaseseriesandliteraturereview
AT ornekfirdevs shortandlongtermresultsofglaucomavalveimplantationforaniridiarelatedglaucomaacaseseriesandliteraturereview