Investigation of a Novel Decision Support Metric for Head and Neck Adaptive Radiation Therapy Using a Real-Time In Vivo Portal Dosimetry System

In adaptive radiation therapy of head and neck cancer, any significant anatomical changes observed are used to adapt the treatment plan to maintain target coverage without elevating the risk of xerostomia. However, the additional resources required for adaptive radiation therapy pose a challenge for...

Descripción completa

Detalles Bibliográficos
Autores principales: Lim, S. B., Tsai, C. J., Yu, Y., Greer, P., Fuangrod, T., Hwang, K., Fontenla, S., Coffman, F., Lee, N., Lovelock, D. M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6763934/
https://www.ncbi.nlm.nih.gov/pubmed/31551011
http://dx.doi.org/10.1177/1533033819873629
_version_ 1783454275106504704
author Lim, S. B.
Tsai, C. J.
Yu, Y.
Greer, P.
Fuangrod, T.
Hwang, K.
Fontenla, S.
Coffman, F.
Lee, N.
Lovelock, D. M.
author_facet Lim, S. B.
Tsai, C. J.
Yu, Y.
Greer, P.
Fuangrod, T.
Hwang, K.
Fontenla, S.
Coffman, F.
Lee, N.
Lovelock, D. M.
author_sort Lim, S. B.
collection PubMed
description In adaptive radiation therapy of head and neck cancer, any significant anatomical changes observed are used to adapt the treatment plan to maintain target coverage without elevating the risk of xerostomia. However, the additional resources required for adaptive radiation therapy pose a challenge for broad-based implementation. It is hypothesized that a change in transit fluence is associated with volumetric change in the vicinity of the target and therefore can be used as a decision support metric for adaptive radiation therapy. This was evaluated by comparing the fluence with volumetric changes in 12 patients. Transit fluence was measured by an in vivo portal dosimetry system. Weekly cone beam computed tomography was used to determine volume change in the rectangular region of interest from condyloid process to C6. The integrated transit fluence through the region of interest on the day of the cone beam computed tomography scan was calculated with the first treatment as the baseline. The correlation between fluence change and volume change was determined. A logistic regression model was also used to associate the 5% region of interest volume reduction replanning trigger point and the fluence change. The model was assessed by a chi-square test. The area under the receiver–operating characteristic curve was also determined. A total of 46 pairs of measurements were obtained. The correlation between fluence and volumetric changes was found to be −0.776 (P value <.001). The negative correlation is attributed to the increase in the photon fluence transport resulting from the volume reduction. The chi-square of the logistic regression was found to be 17.4 (P value <.001). The area under the receiver–operating characteristic curve was found to be 0.88. Results indicate the change in transit fluence, which can be measured without consuming clinical resources or requiring additional time in the treatment room, can be used as a decision support metric for adaptive therapy.
format Online
Article
Text
id pubmed-6763934
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-67639342019-10-09 Investigation of a Novel Decision Support Metric for Head and Neck Adaptive Radiation Therapy Using a Real-Time In Vivo Portal Dosimetry System Lim, S. B. Tsai, C. J. Yu, Y. Greer, P. Fuangrod, T. Hwang, K. Fontenla, S. Coffman, F. Lee, N. Lovelock, D. M. Technol Cancer Res Treat Original Article In adaptive radiation therapy of head and neck cancer, any significant anatomical changes observed are used to adapt the treatment plan to maintain target coverage without elevating the risk of xerostomia. However, the additional resources required for adaptive radiation therapy pose a challenge for broad-based implementation. It is hypothesized that a change in transit fluence is associated with volumetric change in the vicinity of the target and therefore can be used as a decision support metric for adaptive radiation therapy. This was evaluated by comparing the fluence with volumetric changes in 12 patients. Transit fluence was measured by an in vivo portal dosimetry system. Weekly cone beam computed tomography was used to determine volume change in the rectangular region of interest from condyloid process to C6. The integrated transit fluence through the region of interest on the day of the cone beam computed tomography scan was calculated with the first treatment as the baseline. The correlation between fluence change and volume change was determined. A logistic regression model was also used to associate the 5% region of interest volume reduction replanning trigger point and the fluence change. The model was assessed by a chi-square test. The area under the receiver–operating characteristic curve was also determined. A total of 46 pairs of measurements were obtained. The correlation between fluence and volumetric changes was found to be −0.776 (P value <.001). The negative correlation is attributed to the increase in the photon fluence transport resulting from the volume reduction. The chi-square of the logistic regression was found to be 17.4 (P value <.001). The area under the receiver–operating characteristic curve was found to be 0.88. Results indicate the change in transit fluence, which can be measured without consuming clinical resources or requiring additional time in the treatment room, can be used as a decision support metric for adaptive therapy. SAGE Publications 2019-09-24 /pmc/articles/PMC6763934/ /pubmed/31551011 http://dx.doi.org/10.1177/1533033819873629 Text en © The Author(s) 2019 http://creativecommons.org/licenses/by-nc/4.0/ This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (http://www.creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Original Article
Lim, S. B.
Tsai, C. J.
Yu, Y.
Greer, P.
Fuangrod, T.
Hwang, K.
Fontenla, S.
Coffman, F.
Lee, N.
Lovelock, D. M.
Investigation of a Novel Decision Support Metric for Head and Neck Adaptive Radiation Therapy Using a Real-Time In Vivo Portal Dosimetry System
title Investigation of a Novel Decision Support Metric for Head and Neck Adaptive Radiation Therapy Using a Real-Time In Vivo Portal Dosimetry System
title_full Investigation of a Novel Decision Support Metric for Head and Neck Adaptive Radiation Therapy Using a Real-Time In Vivo Portal Dosimetry System
title_fullStr Investigation of a Novel Decision Support Metric for Head and Neck Adaptive Radiation Therapy Using a Real-Time In Vivo Portal Dosimetry System
title_full_unstemmed Investigation of a Novel Decision Support Metric for Head and Neck Adaptive Radiation Therapy Using a Real-Time In Vivo Portal Dosimetry System
title_short Investigation of a Novel Decision Support Metric for Head and Neck Adaptive Radiation Therapy Using a Real-Time In Vivo Portal Dosimetry System
title_sort investigation of a novel decision support metric for head and neck adaptive radiation therapy using a real-time in vivo portal dosimetry system
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6763934/
https://www.ncbi.nlm.nih.gov/pubmed/31551011
http://dx.doi.org/10.1177/1533033819873629
work_keys_str_mv AT limsb investigationofanoveldecisionsupportmetricforheadandneckadaptiveradiationtherapyusingarealtimeinvivoportaldosimetrysystem
AT tsaicj investigationofanoveldecisionsupportmetricforheadandneckadaptiveradiationtherapyusingarealtimeinvivoportaldosimetrysystem
AT yuy investigationofanoveldecisionsupportmetricforheadandneckadaptiveradiationtherapyusingarealtimeinvivoportaldosimetrysystem
AT greerp investigationofanoveldecisionsupportmetricforheadandneckadaptiveradiationtherapyusingarealtimeinvivoportaldosimetrysystem
AT fuangrodt investigationofanoveldecisionsupportmetricforheadandneckadaptiveradiationtherapyusingarealtimeinvivoportaldosimetrysystem
AT hwangk investigationofanoveldecisionsupportmetricforheadandneckadaptiveradiationtherapyusingarealtimeinvivoportaldosimetrysystem
AT fontenlas investigationofanoveldecisionsupportmetricforheadandneckadaptiveradiationtherapyusingarealtimeinvivoportaldosimetrysystem
AT coffmanf investigationofanoveldecisionsupportmetricforheadandneckadaptiveradiationtherapyusingarealtimeinvivoportaldosimetrysystem
AT leen investigationofanoveldecisionsupportmetricforheadandneckadaptiveradiationtherapyusingarealtimeinvivoportaldosimetrysystem
AT lovelockdm investigationofanoveldecisionsupportmetricforheadandneckadaptiveradiationtherapyusingarealtimeinvivoportaldosimetrysystem