Cargando…

Hemodynamic differences among hypertensive patients with and without heart failure using impedance cardiography

BACKGROUND: Impedance cardiography is a reliable, well-tolerated, and non-invasive method used to obtain hemodynamic measurements and could potentially be useful in heart failure (HF) diagnosis, hemodynamic monitoring of critically ill patients, and help in the choice of antihypertensive therapy. Th...

Descripción completa

Detalles Bibliográficos
Autores principales: Silva Lopes, Bruno, Craveiro, Nuno, Firmino-Machado, João, Ribeiro, Pedro, Castelo-Branco, Miguel
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6764032/
https://www.ncbi.nlm.nih.gov/pubmed/31554488
http://dx.doi.org/10.1177/1753944719876517
_version_ 1783454291078414336
author Silva Lopes, Bruno
Craveiro, Nuno
Firmino-Machado, João
Ribeiro, Pedro
Castelo-Branco, Miguel
author_facet Silva Lopes, Bruno
Craveiro, Nuno
Firmino-Machado, João
Ribeiro, Pedro
Castelo-Branco, Miguel
author_sort Silva Lopes, Bruno
collection PubMed
description BACKGROUND: Impedance cardiography is a reliable, well-tolerated, and non-invasive method used to obtain hemodynamic measurements and could potentially be useful in heart failure (HF) diagnosis, hemodynamic monitoring of critically ill patients, and help in the choice of antihypertensive therapy. The objective of this study was to determine the differences between hemodynamic parameters in a study population of hypertensive patients with and without HF, using impedance cardiography. METHODS: A case-control study was designed and named the TARGET study. Participants were enrolled in two study groups: control group C, hypertensive patients without HF and the HF group, hypertensive patients with HF. A descriptive analysis was carried out to characterize the sample and differences in continuous variables were tested for statistical significance by independent sample t test. RESULTS: The study included 102 hypertensive outpatients. The control group consisted of 77 individuals (58.4% males; mean age 63.9 ± 12.5 years old) and the HF group consisted of 25 individuals (44.0% males; mean age 74.2 ± 8.7 years old). The mean Cardiac Index (CI) was 2.70 ± 1.02 L.min.m(−2) (2.89 ± 1.04 versus 2.12 ± 0.70; p < 0.001), mean Stroke Index (SI) was 35.5 ± 14.7 mL.m(−2) (37.7 ± 15.2 versus 28.5 ± 10.8; p = 0.006), mean Ejection Phase Contractility Index (EPCI) was 33.7 ± 12.7 1000 s(−2) (35.8 ± 13.1 versus 27.2 ± 9.2; p = 0.003), mean Inotropic State Index (ISI) was 74.3 ± 28.2 100 s(−2) (78.8 ± 28.9 versus 60.6 ± 20.7; p = 0.005), and mean Left Stroke Work Index (LSWI) was 51.3 ± 23.1 g.min.m(−2) (55.4 ± 23.5 versus 38.9 ± 16.6; p = 0.002). CONCLUSIONS: In this study, hypertensive patients with HF had significantly lower values of blood flow parameters, contractility, and left work indices compared with hypertensive patients without HF. These differences reflected the incorrect hemodynamic pattern (mostly hypodynamic) of these patients. Impedance cardiography (ICG) seems to be an adequate method to reflect these differences.
format Online
Article
Text
id pubmed-6764032
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-67640322019-10-09 Hemodynamic differences among hypertensive patients with and without heart failure using impedance cardiography Silva Lopes, Bruno Craveiro, Nuno Firmino-Machado, João Ribeiro, Pedro Castelo-Branco, Miguel Ther Adv Cardiovasc Dis Original Research BACKGROUND: Impedance cardiography is a reliable, well-tolerated, and non-invasive method used to obtain hemodynamic measurements and could potentially be useful in heart failure (HF) diagnosis, hemodynamic monitoring of critically ill patients, and help in the choice of antihypertensive therapy. The objective of this study was to determine the differences between hemodynamic parameters in a study population of hypertensive patients with and without HF, using impedance cardiography. METHODS: A case-control study was designed and named the TARGET study. Participants were enrolled in two study groups: control group C, hypertensive patients without HF and the HF group, hypertensive patients with HF. A descriptive analysis was carried out to characterize the sample and differences in continuous variables were tested for statistical significance by independent sample t test. RESULTS: The study included 102 hypertensive outpatients. The control group consisted of 77 individuals (58.4% males; mean age 63.9 ± 12.5 years old) and the HF group consisted of 25 individuals (44.0% males; mean age 74.2 ± 8.7 years old). The mean Cardiac Index (CI) was 2.70 ± 1.02 L.min.m(−2) (2.89 ± 1.04 versus 2.12 ± 0.70; p < 0.001), mean Stroke Index (SI) was 35.5 ± 14.7 mL.m(−2) (37.7 ± 15.2 versus 28.5 ± 10.8; p = 0.006), mean Ejection Phase Contractility Index (EPCI) was 33.7 ± 12.7 1000 s(−2) (35.8 ± 13.1 versus 27.2 ± 9.2; p = 0.003), mean Inotropic State Index (ISI) was 74.3 ± 28.2 100 s(−2) (78.8 ± 28.9 versus 60.6 ± 20.7; p = 0.005), and mean Left Stroke Work Index (LSWI) was 51.3 ± 23.1 g.min.m(−2) (55.4 ± 23.5 versus 38.9 ± 16.6; p = 0.002). CONCLUSIONS: In this study, hypertensive patients with HF had significantly lower values of blood flow parameters, contractility, and left work indices compared with hypertensive patients without HF. These differences reflected the incorrect hemodynamic pattern (mostly hypodynamic) of these patients. Impedance cardiography (ICG) seems to be an adequate method to reflect these differences. SAGE Publications 2019-09-25 /pmc/articles/PMC6764032/ /pubmed/31554488 http://dx.doi.org/10.1177/1753944719876517 Text en © The Author(s), 2019 http://www.creativecommons.org/licenses/by-nc/4.0/ This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (http://www.creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Original Research
Silva Lopes, Bruno
Craveiro, Nuno
Firmino-Machado, João
Ribeiro, Pedro
Castelo-Branco, Miguel
Hemodynamic differences among hypertensive patients with and without heart failure using impedance cardiography
title Hemodynamic differences among hypertensive patients with and without heart failure using impedance cardiography
title_full Hemodynamic differences among hypertensive patients with and without heart failure using impedance cardiography
title_fullStr Hemodynamic differences among hypertensive patients with and without heart failure using impedance cardiography
title_full_unstemmed Hemodynamic differences among hypertensive patients with and without heart failure using impedance cardiography
title_short Hemodynamic differences among hypertensive patients with and without heart failure using impedance cardiography
title_sort hemodynamic differences among hypertensive patients with and without heart failure using impedance cardiography
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6764032/
https://www.ncbi.nlm.nih.gov/pubmed/31554488
http://dx.doi.org/10.1177/1753944719876517
work_keys_str_mv AT silvalopesbruno hemodynamicdifferencesamonghypertensivepatientswithandwithoutheartfailureusingimpedancecardiography
AT craveironuno hemodynamicdifferencesamonghypertensivepatientswithandwithoutheartfailureusingimpedancecardiography
AT firminomachadojoao hemodynamicdifferencesamonghypertensivepatientswithandwithoutheartfailureusingimpedancecardiography
AT ribeiropedro hemodynamicdifferencesamonghypertensivepatientswithandwithoutheartfailureusingimpedancecardiography
AT castelobrancomiguel hemodynamicdifferencesamonghypertensivepatientswithandwithoutheartfailureusingimpedancecardiography