Cargando…
Refractive outcomes of implantation of an implantable phakic copolymer lens with peripheral holes in the intraocular posterior chamber in moderate to high myopia patients: a single-surgeon series
PURPOSE: To assess the safety and efficacy of implanting implantable phakic copolymer lenses (IPCLs) with peripheral optic holes in the intraocular posterior chamber in Indian patients with moderate to high myopia. METHODS: Seventy-five eyes of 50 patients who underwent IPCL implantation were retros...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6765325/ https://www.ncbi.nlm.nih.gov/pubmed/31576104 http://dx.doi.org/10.2147/OPTH.S215821 |
_version_ | 1783454537687760896 |
---|---|
author | Subudhi, Praveen Patro, Sweta Khan, Zahiruddin Subudhi, B Nageswar Rao Sitaram, Silla |
author_facet | Subudhi, Praveen Patro, Sweta Khan, Zahiruddin Subudhi, B Nageswar Rao Sitaram, Silla |
author_sort | Subudhi, Praveen |
collection | PubMed |
description | PURPOSE: To assess the safety and efficacy of implanting implantable phakic copolymer lenses (IPCLs) with peripheral optic holes in the intraocular posterior chamber in Indian patients with moderate to high myopia. METHODS: Seventy-five eyes of 50 patients who underwent IPCL implantation were retrospectively analyzed. Preoperative parameters, such as subjective refraction, anterior chamber depth (measured using a pentacam), and white-to-white diameter were measured. A custom-made IPCL using the aforementioned parameters was then implanted in the sulcus to correct moderate to high myopia. All patients had undergone neodymium-doped yttrium aluminum garnet peripheral iridotomy. RESULTS: Clinical outcome data were collated retrospectively from the medical case records of the patients. The mean age was 25.36 years (standard deviation [SD]: 3.60 years), and 55.55% of the patients were men. The mean preoperative best-corrected visual acuity (BCVA) was 0.367 logmar units (SD: 0.266, max: 0.0 and min: 1.2). The post-IPCL implantation mean uncorrected visual acuity was 0.225 logmar units (SD: 0.172, max: 0 and min: 0.7), which was significantly superior to the preoperative BCVA (P=<0.0001). Forty-three patients (86%; satisfaction scores of ≥4; scale 1–5) were “highly satisfied” to “extremely satisfied” with the outcome. The mean follow-up period was 1.8 years. CONCLUSION: Implantation of the IPCL with peripheral holes in the intraocular posterior chamber resulted in a clinically significant improvement in unaided visual acuity. Long-term follow-up showed optimum stability of vision. |
format | Online Article Text |
id | pubmed-6765325 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Dove |
record_format | MEDLINE/PubMed |
spelling | pubmed-67653252019-10-01 Refractive outcomes of implantation of an implantable phakic copolymer lens with peripheral holes in the intraocular posterior chamber in moderate to high myopia patients: a single-surgeon series Subudhi, Praveen Patro, Sweta Khan, Zahiruddin Subudhi, B Nageswar Rao Sitaram, Silla Clin Ophthalmol Original Research PURPOSE: To assess the safety and efficacy of implanting implantable phakic copolymer lenses (IPCLs) with peripheral optic holes in the intraocular posterior chamber in Indian patients with moderate to high myopia. METHODS: Seventy-five eyes of 50 patients who underwent IPCL implantation were retrospectively analyzed. Preoperative parameters, such as subjective refraction, anterior chamber depth (measured using a pentacam), and white-to-white diameter were measured. A custom-made IPCL using the aforementioned parameters was then implanted in the sulcus to correct moderate to high myopia. All patients had undergone neodymium-doped yttrium aluminum garnet peripheral iridotomy. RESULTS: Clinical outcome data were collated retrospectively from the medical case records of the patients. The mean age was 25.36 years (standard deviation [SD]: 3.60 years), and 55.55% of the patients were men. The mean preoperative best-corrected visual acuity (BCVA) was 0.367 logmar units (SD: 0.266, max: 0.0 and min: 1.2). The post-IPCL implantation mean uncorrected visual acuity was 0.225 logmar units (SD: 0.172, max: 0 and min: 0.7), which was significantly superior to the preoperative BCVA (P=<0.0001). Forty-three patients (86%; satisfaction scores of ≥4; scale 1–5) were “highly satisfied” to “extremely satisfied” with the outcome. The mean follow-up period was 1.8 years. CONCLUSION: Implantation of the IPCL with peripheral holes in the intraocular posterior chamber resulted in a clinically significant improvement in unaided visual acuity. Long-term follow-up showed optimum stability of vision. Dove 2019-09-23 /pmc/articles/PMC6765325/ /pubmed/31576104 http://dx.doi.org/10.2147/OPTH.S215821 Text en © 2019 Subudhi et al. http://creativecommons.org/licenses/by-nc/3.0/ This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php). |
spellingShingle | Original Research Subudhi, Praveen Patro, Sweta Khan, Zahiruddin Subudhi, B Nageswar Rao Sitaram, Silla Refractive outcomes of implantation of an implantable phakic copolymer lens with peripheral holes in the intraocular posterior chamber in moderate to high myopia patients: a single-surgeon series |
title | Refractive outcomes of implantation of an implantable phakic copolymer lens with peripheral holes in the intraocular posterior chamber in moderate to high myopia patients: a single-surgeon series |
title_full | Refractive outcomes of implantation of an implantable phakic copolymer lens with peripheral holes in the intraocular posterior chamber in moderate to high myopia patients: a single-surgeon series |
title_fullStr | Refractive outcomes of implantation of an implantable phakic copolymer lens with peripheral holes in the intraocular posterior chamber in moderate to high myopia patients: a single-surgeon series |
title_full_unstemmed | Refractive outcomes of implantation of an implantable phakic copolymer lens with peripheral holes in the intraocular posterior chamber in moderate to high myopia patients: a single-surgeon series |
title_short | Refractive outcomes of implantation of an implantable phakic copolymer lens with peripheral holes in the intraocular posterior chamber in moderate to high myopia patients: a single-surgeon series |
title_sort | refractive outcomes of implantation of an implantable phakic copolymer lens with peripheral holes in the intraocular posterior chamber in moderate to high myopia patients: a single-surgeon series |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6765325/ https://www.ncbi.nlm.nih.gov/pubmed/31576104 http://dx.doi.org/10.2147/OPTH.S215821 |
work_keys_str_mv | AT subudhipraveen refractiveoutcomesofimplantationofanimplantablephakiccopolymerlenswithperipheralholesintheintraocularposteriorchamberinmoderatetohighmyopiapatientsasinglesurgeonseries AT patrosweta refractiveoutcomesofimplantationofanimplantablephakiccopolymerlenswithperipheralholesintheintraocularposteriorchamberinmoderatetohighmyopiapatientsasinglesurgeonseries AT khanzahiruddin refractiveoutcomesofimplantationofanimplantablephakiccopolymerlenswithperipheralholesintheintraocularposteriorchamberinmoderatetohighmyopiapatientsasinglesurgeonseries AT subudhibnageswarrao refractiveoutcomesofimplantationofanimplantablephakiccopolymerlenswithperipheralholesintheintraocularposteriorchamberinmoderatetohighmyopiapatientsasinglesurgeonseries AT sitaramsilla refractiveoutcomesofimplantationofanimplantablephakiccopolymerlenswithperipheralholesintheintraocularposteriorchamberinmoderatetohighmyopiapatientsasinglesurgeonseries |