Cargando…

Feasibility and usefulness of endoscopic ultrasonography-guided shear-wave measurement for assessment of autoimmune pancreatitis activity: a prospective exploratory study

PURPOSE: To assess the feasibility and the clinical usefulness of a newly developed endoscopic ultrasonography (EUS) shear-wave elastography technique (EUS shear-wave measurement: EUS-SWM) in the diagnosis and treatment of autoimmune pancreatitis (AIP). METHODS: Tissue elasticity was measured in the...

Descripción completa

Detalles Bibliográficos
Autores principales: Ohno, Eizaburo, Hirooka, Yoshiki, Kawashima, Hiroki, Ishikawa, Takuya, Tanaka, Hiroyuki, Sakai, Daisuke, Ishizu, Yoji, Kuzuya, Teiji, Nakamura, Masanao, Honda, Takashi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Singapore 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6765472/
https://www.ncbi.nlm.nih.gov/pubmed/30993580
http://dx.doi.org/10.1007/s10396-019-00944-4
_version_ 1783454553003261952
author Ohno, Eizaburo
Hirooka, Yoshiki
Kawashima, Hiroki
Ishikawa, Takuya
Tanaka, Hiroyuki
Sakai, Daisuke
Ishizu, Yoji
Kuzuya, Teiji
Nakamura, Masanao
Honda, Takashi
author_facet Ohno, Eizaburo
Hirooka, Yoshiki
Kawashima, Hiroki
Ishikawa, Takuya
Tanaka, Hiroyuki
Sakai, Daisuke
Ishizu, Yoji
Kuzuya, Teiji
Nakamura, Masanao
Honda, Takashi
author_sort Ohno, Eizaburo
collection PubMed
description PURPOSE: To assess the feasibility and the clinical usefulness of a newly developed endoscopic ultrasonography (EUS) shear-wave elastography technique (EUS shear-wave measurement: EUS-SWM) in the diagnosis and treatment of autoimmune pancreatitis (AIP). METHODS: Tissue elasticity was measured in the pancreas in 160 patients. The success rate of EUS-SWMs, the velocity of the shear wave (Vs, m/s), and the reliability index of the Vs measurement (VsN) were evaluated, and the elasticity (median Vs) was compared between AIP patients (n = 14) and normal controls. RESULTS: A total of 3837 EUS-SWMs were performed without adverse events. Overall, 97.6% (3743/3837) were successful. The median VsN was 74%. The median Vs values of the pancreas were as follows: 2.22 m/s in the pancreatic head (push position), 2.36 m/s in the head (pull position), 1.99 m/s in the body, and 2.25 m/s in the tail. The median Vs of the AIP group (2.57 m/s) was significantly higher than that of the normal controls (1.89 m/s) (P = 0.0185). The mean Vs significantly decreased from 3.32 m/s to 2.46 m/s after steroid therapy (n = 6) (P = 0.0234). CONCLUSION: EUS-SWM is feasible and generates credible results. EUS-SWM was a useful method for assessment of the effect of steroid therapy in AIP patients. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s10396-019-00944-4) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-6765472
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Springer Singapore
record_format MEDLINE/PubMed
spelling pubmed-67654722019-10-09 Feasibility and usefulness of endoscopic ultrasonography-guided shear-wave measurement for assessment of autoimmune pancreatitis activity: a prospective exploratory study Ohno, Eizaburo Hirooka, Yoshiki Kawashima, Hiroki Ishikawa, Takuya Tanaka, Hiroyuki Sakai, Daisuke Ishizu, Yoji Kuzuya, Teiji Nakamura, Masanao Honda, Takashi J Med Ultrason (2001) Original Article—Gastroenterology PURPOSE: To assess the feasibility and the clinical usefulness of a newly developed endoscopic ultrasonography (EUS) shear-wave elastography technique (EUS shear-wave measurement: EUS-SWM) in the diagnosis and treatment of autoimmune pancreatitis (AIP). METHODS: Tissue elasticity was measured in the pancreas in 160 patients. The success rate of EUS-SWMs, the velocity of the shear wave (Vs, m/s), and the reliability index of the Vs measurement (VsN) were evaluated, and the elasticity (median Vs) was compared between AIP patients (n = 14) and normal controls. RESULTS: A total of 3837 EUS-SWMs were performed without adverse events. Overall, 97.6% (3743/3837) were successful. The median VsN was 74%. The median Vs values of the pancreas were as follows: 2.22 m/s in the pancreatic head (push position), 2.36 m/s in the head (pull position), 1.99 m/s in the body, and 2.25 m/s in the tail. The median Vs of the AIP group (2.57 m/s) was significantly higher than that of the normal controls (1.89 m/s) (P = 0.0185). The mean Vs significantly decreased from 3.32 m/s to 2.46 m/s after steroid therapy (n = 6) (P = 0.0234). CONCLUSION: EUS-SWM is feasible and generates credible results. EUS-SWM was a useful method for assessment of the effect of steroid therapy in AIP patients. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s10396-019-00944-4) contains supplementary material, which is available to authorized users. Springer Singapore 2019-04-16 2019 /pmc/articles/PMC6765472/ /pubmed/30993580 http://dx.doi.org/10.1007/s10396-019-00944-4 Text en © The Author(s) 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Original Article—Gastroenterology
Ohno, Eizaburo
Hirooka, Yoshiki
Kawashima, Hiroki
Ishikawa, Takuya
Tanaka, Hiroyuki
Sakai, Daisuke
Ishizu, Yoji
Kuzuya, Teiji
Nakamura, Masanao
Honda, Takashi
Feasibility and usefulness of endoscopic ultrasonography-guided shear-wave measurement for assessment of autoimmune pancreatitis activity: a prospective exploratory study
title Feasibility and usefulness of endoscopic ultrasonography-guided shear-wave measurement for assessment of autoimmune pancreatitis activity: a prospective exploratory study
title_full Feasibility and usefulness of endoscopic ultrasonography-guided shear-wave measurement for assessment of autoimmune pancreatitis activity: a prospective exploratory study
title_fullStr Feasibility and usefulness of endoscopic ultrasonography-guided shear-wave measurement for assessment of autoimmune pancreatitis activity: a prospective exploratory study
title_full_unstemmed Feasibility and usefulness of endoscopic ultrasonography-guided shear-wave measurement for assessment of autoimmune pancreatitis activity: a prospective exploratory study
title_short Feasibility and usefulness of endoscopic ultrasonography-guided shear-wave measurement for assessment of autoimmune pancreatitis activity: a prospective exploratory study
title_sort feasibility and usefulness of endoscopic ultrasonography-guided shear-wave measurement for assessment of autoimmune pancreatitis activity: a prospective exploratory study
topic Original Article—Gastroenterology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6765472/
https://www.ncbi.nlm.nih.gov/pubmed/30993580
http://dx.doi.org/10.1007/s10396-019-00944-4
work_keys_str_mv AT ohnoeizaburo feasibilityandusefulnessofendoscopicultrasonographyguidedshearwavemeasurementforassessmentofautoimmunepancreatitisactivityaprospectiveexploratorystudy
AT hirookayoshiki feasibilityandusefulnessofendoscopicultrasonographyguidedshearwavemeasurementforassessmentofautoimmunepancreatitisactivityaprospectiveexploratorystudy
AT kawashimahiroki feasibilityandusefulnessofendoscopicultrasonographyguidedshearwavemeasurementforassessmentofautoimmunepancreatitisactivityaprospectiveexploratorystudy
AT ishikawatakuya feasibilityandusefulnessofendoscopicultrasonographyguidedshearwavemeasurementforassessmentofautoimmunepancreatitisactivityaprospectiveexploratorystudy
AT tanakahiroyuki feasibilityandusefulnessofendoscopicultrasonographyguidedshearwavemeasurementforassessmentofautoimmunepancreatitisactivityaprospectiveexploratorystudy
AT sakaidaisuke feasibilityandusefulnessofendoscopicultrasonographyguidedshearwavemeasurementforassessmentofautoimmunepancreatitisactivityaprospectiveexploratorystudy
AT ishizuyoji feasibilityandusefulnessofendoscopicultrasonographyguidedshearwavemeasurementforassessmentofautoimmunepancreatitisactivityaprospectiveexploratorystudy
AT kuzuyateiji feasibilityandusefulnessofendoscopicultrasonographyguidedshearwavemeasurementforassessmentofautoimmunepancreatitisactivityaprospectiveexploratorystudy
AT nakamuramasanao feasibilityandusefulnessofendoscopicultrasonographyguidedshearwavemeasurementforassessmentofautoimmunepancreatitisactivityaprospectiveexploratorystudy
AT hondatakashi feasibilityandusefulnessofendoscopicultrasonographyguidedshearwavemeasurementforassessmentofautoimmunepancreatitisactivityaprospectiveexploratorystudy