Cargando…

A Smartphone-Based Whole-Cell Array Sensor for Detection of Antibiotics in Milk

We present an integral smartphone-based whole-cell biosensor, LumiCellSense (LCS), which incorporates a 16-well biochip with an oxygen permeable coating, harboring bioluminescent Escherichia coli bioreporter cells, a macro lens, a lens barrel, a metal heater tray, and a temperature controller, enclo...

Descripción completa

Detalles Bibliográficos
Autores principales: Lu, Mei-Yi, Kao, Wei-Chen, Belkin, Shimshon, Cheng, Ji-Yen
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6767005/
https://www.ncbi.nlm.nih.gov/pubmed/31505815
http://dx.doi.org/10.3390/s19183882
_version_ 1783454816779894784
author Lu, Mei-Yi
Kao, Wei-Chen
Belkin, Shimshon
Cheng, Ji-Yen
author_facet Lu, Mei-Yi
Kao, Wei-Chen
Belkin, Shimshon
Cheng, Ji-Yen
author_sort Lu, Mei-Yi
collection PubMed
description We present an integral smartphone-based whole-cell biosensor, LumiCellSense (LCS), which incorporates a 16-well biochip with an oxygen permeable coating, harboring bioluminescent Escherichia coli bioreporter cells, a macro lens, a lens barrel, a metal heater tray, and a temperature controller, enclosed in a light-impermeable case. The luminescence emitted by the bioreporter cells in response to the presence of the target chemicals is imaged by the phone’s camera, and a dedicated phone-embedded application, LCS_Logger, is employed to calculate photon emission intensity and plot it in real time on the device’s screen. An alert is automatically given when light intensity increases above the baseline, indicating the presence of the target. We demonstrate the efficacy of this system by the detection of residues of an antibiotic, ciprofloxacin (CIP), in whole milk, with a detection threshold of 7.2 ng/mL. This value is below the allowed maximum as defined by European Union regulations.
format Online
Article
Text
id pubmed-6767005
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-67670052019-10-02 A Smartphone-Based Whole-Cell Array Sensor for Detection of Antibiotics in Milk Lu, Mei-Yi Kao, Wei-Chen Belkin, Shimshon Cheng, Ji-Yen Sensors (Basel) Article We present an integral smartphone-based whole-cell biosensor, LumiCellSense (LCS), which incorporates a 16-well biochip with an oxygen permeable coating, harboring bioluminescent Escherichia coli bioreporter cells, a macro lens, a lens barrel, a metal heater tray, and a temperature controller, enclosed in a light-impermeable case. The luminescence emitted by the bioreporter cells in response to the presence of the target chemicals is imaged by the phone’s camera, and a dedicated phone-embedded application, LCS_Logger, is employed to calculate photon emission intensity and plot it in real time on the device’s screen. An alert is automatically given when light intensity increases above the baseline, indicating the presence of the target. We demonstrate the efficacy of this system by the detection of residues of an antibiotic, ciprofloxacin (CIP), in whole milk, with a detection threshold of 7.2 ng/mL. This value is below the allowed maximum as defined by European Union regulations. MDPI 2019-09-09 /pmc/articles/PMC6767005/ /pubmed/31505815 http://dx.doi.org/10.3390/s19183882 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Lu, Mei-Yi
Kao, Wei-Chen
Belkin, Shimshon
Cheng, Ji-Yen
A Smartphone-Based Whole-Cell Array Sensor for Detection of Antibiotics in Milk
title A Smartphone-Based Whole-Cell Array Sensor for Detection of Antibiotics in Milk
title_full A Smartphone-Based Whole-Cell Array Sensor for Detection of Antibiotics in Milk
title_fullStr A Smartphone-Based Whole-Cell Array Sensor for Detection of Antibiotics in Milk
title_full_unstemmed A Smartphone-Based Whole-Cell Array Sensor for Detection of Antibiotics in Milk
title_short A Smartphone-Based Whole-Cell Array Sensor for Detection of Antibiotics in Milk
title_sort smartphone-based whole-cell array sensor for detection of antibiotics in milk
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6767005/
https://www.ncbi.nlm.nih.gov/pubmed/31505815
http://dx.doi.org/10.3390/s19183882
work_keys_str_mv AT lumeiyi asmartphonebasedwholecellarraysensorfordetectionofantibioticsinmilk
AT kaoweichen asmartphonebasedwholecellarraysensorfordetectionofantibioticsinmilk
AT belkinshimshon asmartphonebasedwholecellarraysensorfordetectionofantibioticsinmilk
AT chengjiyen asmartphonebasedwholecellarraysensorfordetectionofantibioticsinmilk
AT lumeiyi smartphonebasedwholecellarraysensorfordetectionofantibioticsinmilk
AT kaoweichen smartphonebasedwholecellarraysensorfordetectionofantibioticsinmilk
AT belkinshimshon smartphonebasedwholecellarraysensorfordetectionofantibioticsinmilk
AT chengjiyen smartphonebasedwholecellarraysensorfordetectionofantibioticsinmilk