Cargando…
Flex Sensor Compensator via Hammerstein–Wiener Modeling Approach for Improved Dynamic Goniometry and Constrained Control of a Bionic Hand
In this paper, a new control-centric approach is introduced to model the characteristics of flex sensors on a goniometric glove, which is designed to capture the user hand gesture that can be used to wirelessly control a bionic hand. The main technique employs the inverse dynamic model strategy alon...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6767013/ https://www.ncbi.nlm.nih.gov/pubmed/31509987 http://dx.doi.org/10.3390/s19183896 |
_version_ | 1783454818625388544 |
---|---|
author | Syed Mubarak Ali, Syed Afdar Ali Ahmad, Nur Syazreen Goh, Patrick |
author_facet | Syed Mubarak Ali, Syed Afdar Ali Ahmad, Nur Syazreen Goh, Patrick |
author_sort | Syed Mubarak Ali, Syed Afdar Ali |
collection | PubMed |
description | In this paper, a new control-centric approach is introduced to model the characteristics of flex sensors on a goniometric glove, which is designed to capture the user hand gesture that can be used to wirelessly control a bionic hand. The main technique employs the inverse dynamic model strategy along with a black-box identification for the compensator design, which is aimed to provide an approximate linear mapping between the raw sensor output and the dynamic finger goniometry. To smoothly recover the goniometry on the bionic hand’s side during the wireless transmission, the compensator is restructured into a Hammerstein–Wiener model, which consists of a linear dynamic system and two static nonlinearities. A series of real-time experiments involving several hand gestures have been conducted to analyze the performance of the proposed method. The associated temporal and spatial gesture data from both the glove and the bionic hand are recorded, and the performance is evaluated in terms of the integral of absolute error between the glove’s and the bionic hand’s dynamic goniometry. The proposed method is also compared with the raw sensor data, which has been preliminarily calibrated with the finger goniometry, and the Wiener model, which is based on the initial inverse dynamic design strategy. Experimental results with several trials for each gesture show that a great improvement is obtained via the Hammerstein–Wiener compensator approach where the resulting average errors are significantly smaller than the other two methods. This concludes that the proposed strategy can remarkably improve the dynamic goniometry of the glove, and thus provides a smooth human–robot collaboration with the bionic hand. |
format | Online Article Text |
id | pubmed-6767013 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-67670132019-10-02 Flex Sensor Compensator via Hammerstein–Wiener Modeling Approach for Improved Dynamic Goniometry and Constrained Control of a Bionic Hand Syed Mubarak Ali, Syed Afdar Ali Ahmad, Nur Syazreen Goh, Patrick Sensors (Basel) Article In this paper, a new control-centric approach is introduced to model the characteristics of flex sensors on a goniometric glove, which is designed to capture the user hand gesture that can be used to wirelessly control a bionic hand. The main technique employs the inverse dynamic model strategy along with a black-box identification for the compensator design, which is aimed to provide an approximate linear mapping between the raw sensor output and the dynamic finger goniometry. To smoothly recover the goniometry on the bionic hand’s side during the wireless transmission, the compensator is restructured into a Hammerstein–Wiener model, which consists of a linear dynamic system and two static nonlinearities. A series of real-time experiments involving several hand gestures have been conducted to analyze the performance of the proposed method. The associated temporal and spatial gesture data from both the glove and the bionic hand are recorded, and the performance is evaluated in terms of the integral of absolute error between the glove’s and the bionic hand’s dynamic goniometry. The proposed method is also compared with the raw sensor data, which has been preliminarily calibrated with the finger goniometry, and the Wiener model, which is based on the initial inverse dynamic design strategy. Experimental results with several trials for each gesture show that a great improvement is obtained via the Hammerstein–Wiener compensator approach where the resulting average errors are significantly smaller than the other two methods. This concludes that the proposed strategy can remarkably improve the dynamic goniometry of the glove, and thus provides a smooth human–robot collaboration with the bionic hand. MDPI 2019-09-10 /pmc/articles/PMC6767013/ /pubmed/31509987 http://dx.doi.org/10.3390/s19183896 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Syed Mubarak Ali, Syed Afdar Ali Ahmad, Nur Syazreen Goh, Patrick Flex Sensor Compensator via Hammerstein–Wiener Modeling Approach for Improved Dynamic Goniometry and Constrained Control of a Bionic Hand |
title | Flex Sensor Compensator via Hammerstein–Wiener Modeling Approach for Improved Dynamic Goniometry and Constrained Control of a Bionic Hand |
title_full | Flex Sensor Compensator via Hammerstein–Wiener Modeling Approach for Improved Dynamic Goniometry and Constrained Control of a Bionic Hand |
title_fullStr | Flex Sensor Compensator via Hammerstein–Wiener Modeling Approach for Improved Dynamic Goniometry and Constrained Control of a Bionic Hand |
title_full_unstemmed | Flex Sensor Compensator via Hammerstein–Wiener Modeling Approach for Improved Dynamic Goniometry and Constrained Control of a Bionic Hand |
title_short | Flex Sensor Compensator via Hammerstein–Wiener Modeling Approach for Improved Dynamic Goniometry and Constrained Control of a Bionic Hand |
title_sort | flex sensor compensator via hammerstein–wiener modeling approach for improved dynamic goniometry and constrained control of a bionic hand |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6767013/ https://www.ncbi.nlm.nih.gov/pubmed/31509987 http://dx.doi.org/10.3390/s19183896 |
work_keys_str_mv | AT syedmubarakalisyedafdarali flexsensorcompensatorviahammersteinwienermodelingapproachforimproveddynamicgoniometryandconstrainedcontrolofabionichand AT ahmadnursyazreen flexsensorcompensatorviahammersteinwienermodelingapproachforimproveddynamicgoniometryandconstrainedcontrolofabionichand AT gohpatrick flexsensorcompensatorviahammersteinwienermodelingapproachforimproveddynamicgoniometryandconstrainedcontrolofabionichand |