Cargando…

Impedimetric Immunosensor Utilizing Polyaniline/Gold Nanocomposite-Modified Screen-Printed Electrodes for Early Detection of Chronic Kidney Disease

The presence of small amounts of human serum albumin (HSA) in urine or microalbuminuria (30–300 µg/mL) is a valuable clinical biomarker for the early detection of chronic kidney disease (CKD). Herein, we report on the development of an inexpensive and disposable immunosensor for the sensitive, speci...

Descripción completa

Detalles Bibliográficos
Autores principales: Shaikh, Muhammad Omar, Srikanth, Boyanagunta, Zhu, Pei-Yu, Chuang, Cheng-Hsin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6767334/
https://www.ncbi.nlm.nih.gov/pubmed/31527396
http://dx.doi.org/10.3390/s19183990
_version_ 1783454893770539008
author Shaikh, Muhammad Omar
Srikanth, Boyanagunta
Zhu, Pei-Yu
Chuang, Cheng-Hsin
author_facet Shaikh, Muhammad Omar
Srikanth, Boyanagunta
Zhu, Pei-Yu
Chuang, Cheng-Hsin
author_sort Shaikh, Muhammad Omar
collection PubMed
description The presence of small amounts of human serum albumin (HSA) in urine or microalbuminuria (30–300 µg/mL) is a valuable clinical biomarker for the early detection of chronic kidney disease (CKD). Herein, we report on the development of an inexpensive and disposable immunosensor for the sensitive, specific, and label-free detection of HSA using electrochemical impedance spectroscopy (EIS). We have utilized a simple one-step screen-printing protocol to fabricate the carbon-based three-electrode system on flexible plastic substrates. To enable efficient antibody immobilization and improved sensitivity, the carbon working electrode was sequentially modified with electropolymerized polyaniline (PANI) and electrodeposited gold nanocrystals (AuNCs). The PANI matrix serves as an interconnected nanostructured scaffold for homogeneous distribution of AuNCs and the resulting PANI/AuNCs nanocomposite synergically improved the immunosensor response. The PANI/AuNCs-modified working electrode surface was characterized using scanning electron microscopy (SEM) and the electrochemical response at each step was analyzed using EIS in a ferri/ferrocyanide redox probe solution. The normalized impedance variation during immunosensing increased linearly with HSA concentration in the range of 3–300 µg/mL and a highly repeatable response was observed for each concentration. Furthermore, the immunosensor displayed high specificity when tested using spiked sample solutions containing different concentrations of actin protein and J82 cell lysate (a complex fluid containing a multitude of interfering proteins). Consequently, these experimental results confirm the feasibility of the proposed immunosensor for early diagnosis and prognosis of CKD at the point of care.
format Online
Article
Text
id pubmed-6767334
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-67673342019-10-02 Impedimetric Immunosensor Utilizing Polyaniline/Gold Nanocomposite-Modified Screen-Printed Electrodes for Early Detection of Chronic Kidney Disease Shaikh, Muhammad Omar Srikanth, Boyanagunta Zhu, Pei-Yu Chuang, Cheng-Hsin Sensors (Basel) Article The presence of small amounts of human serum albumin (HSA) in urine or microalbuminuria (30–300 µg/mL) is a valuable clinical biomarker for the early detection of chronic kidney disease (CKD). Herein, we report on the development of an inexpensive and disposable immunosensor for the sensitive, specific, and label-free detection of HSA using electrochemical impedance spectroscopy (EIS). We have utilized a simple one-step screen-printing protocol to fabricate the carbon-based three-electrode system on flexible plastic substrates. To enable efficient antibody immobilization and improved sensitivity, the carbon working electrode was sequentially modified with electropolymerized polyaniline (PANI) and electrodeposited gold nanocrystals (AuNCs). The PANI matrix serves as an interconnected nanostructured scaffold for homogeneous distribution of AuNCs and the resulting PANI/AuNCs nanocomposite synergically improved the immunosensor response. The PANI/AuNCs-modified working electrode surface was characterized using scanning electron microscopy (SEM) and the electrochemical response at each step was analyzed using EIS in a ferri/ferrocyanide redox probe solution. The normalized impedance variation during immunosensing increased linearly with HSA concentration in the range of 3–300 µg/mL and a highly repeatable response was observed for each concentration. Furthermore, the immunosensor displayed high specificity when tested using spiked sample solutions containing different concentrations of actin protein and J82 cell lysate (a complex fluid containing a multitude of interfering proteins). Consequently, these experimental results confirm the feasibility of the proposed immunosensor for early diagnosis and prognosis of CKD at the point of care. MDPI 2019-09-16 /pmc/articles/PMC6767334/ /pubmed/31527396 http://dx.doi.org/10.3390/s19183990 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Shaikh, Muhammad Omar
Srikanth, Boyanagunta
Zhu, Pei-Yu
Chuang, Cheng-Hsin
Impedimetric Immunosensor Utilizing Polyaniline/Gold Nanocomposite-Modified Screen-Printed Electrodes for Early Detection of Chronic Kidney Disease
title Impedimetric Immunosensor Utilizing Polyaniline/Gold Nanocomposite-Modified Screen-Printed Electrodes for Early Detection of Chronic Kidney Disease
title_full Impedimetric Immunosensor Utilizing Polyaniline/Gold Nanocomposite-Modified Screen-Printed Electrodes for Early Detection of Chronic Kidney Disease
title_fullStr Impedimetric Immunosensor Utilizing Polyaniline/Gold Nanocomposite-Modified Screen-Printed Electrodes for Early Detection of Chronic Kidney Disease
title_full_unstemmed Impedimetric Immunosensor Utilizing Polyaniline/Gold Nanocomposite-Modified Screen-Printed Electrodes for Early Detection of Chronic Kidney Disease
title_short Impedimetric Immunosensor Utilizing Polyaniline/Gold Nanocomposite-Modified Screen-Printed Electrodes for Early Detection of Chronic Kidney Disease
title_sort impedimetric immunosensor utilizing polyaniline/gold nanocomposite-modified screen-printed electrodes for early detection of chronic kidney disease
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6767334/
https://www.ncbi.nlm.nih.gov/pubmed/31527396
http://dx.doi.org/10.3390/s19183990
work_keys_str_mv AT shaikhmuhammadomar impedimetricimmunosensorutilizingpolyanilinegoldnanocompositemodifiedscreenprintedelectrodesforearlydetectionofchronickidneydisease
AT srikanthboyanagunta impedimetricimmunosensorutilizingpolyanilinegoldnanocompositemodifiedscreenprintedelectrodesforearlydetectionofchronickidneydisease
AT zhupeiyu impedimetricimmunosensorutilizingpolyanilinegoldnanocompositemodifiedscreenprintedelectrodesforearlydetectionofchronickidneydisease
AT chuangchenghsin impedimetricimmunosensorutilizingpolyanilinegoldnanocompositemodifiedscreenprintedelectrodesforearlydetectionofchronickidneydisease