Dual-Channel Spectral Domain Optical Coherence Tomography Based on a Single Spectrometer Using Compressive Sensing

Dual-channel spectral domain optical coherence tomography (SD-OCT) is one of the effective methods for improving imaging depth and imaging speed. In this paper, we design a dual-channel SD-OCT system based on a single spectrometer that can operate in two modes: (1) Increasing imaging speed and (2) e...

Descripción completa

Detalles Bibliográficos
Autores principales: Yi, Luying, Sun, Liqun, Zou, Mingli, Hou, Bo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6767665/
https://www.ncbi.nlm.nih.gov/pubmed/31527515
http://dx.doi.org/10.3390/s19184006
_version_ 1783454967314513920
author Yi, Luying
Sun, Liqun
Zou, Mingli
Hou, Bo
author_facet Yi, Luying
Sun, Liqun
Zou, Mingli
Hou, Bo
author_sort Yi, Luying
collection PubMed
description Dual-channel spectral domain optical coherence tomography (SD-OCT) is one of the effective methods for improving imaging depth and imaging speed. In this paper, we design a dual-channel SD-OCT system based on a single spectrometer that can operate in two modes: (1) Increasing imaging speed and (2) expanding imaging depth. An optical path offset is preintroduced between the two channels to separate the two-channel data. However, this offset increases the requirement for the spectral resolution of the spectrometer in mode (1), so compressive sensing (CS) technology is used herein to overcome this problem. Consequently, in mode (1), when the spectral resolution of the spectrometer is the same as that used in the single-channel system, we use a dual-channel SD-OCT system combined with CS technology to double the imaging speed. In mode (2), when the spectral resolution of the spectrometer is only half of that used in a single-channel system, the imaging depth can be nearly doubled. We demonstrate the feasibility and effectiveness of the method proposed in this work by imaging a mirror, a fish fin, a fish eye, and an onion.
format Online
Article
Text
id pubmed-6767665
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-67676652019-10-02 Dual-Channel Spectral Domain Optical Coherence Tomography Based on a Single Spectrometer Using Compressive Sensing Yi, Luying Sun, Liqun Zou, Mingli Hou, Bo Sensors (Basel) Article Dual-channel spectral domain optical coherence tomography (SD-OCT) is one of the effective methods for improving imaging depth and imaging speed. In this paper, we design a dual-channel SD-OCT system based on a single spectrometer that can operate in two modes: (1) Increasing imaging speed and (2) expanding imaging depth. An optical path offset is preintroduced between the two channels to separate the two-channel data. However, this offset increases the requirement for the spectral resolution of the spectrometer in mode (1), so compressive sensing (CS) technology is used herein to overcome this problem. Consequently, in mode (1), when the spectral resolution of the spectrometer is the same as that used in the single-channel system, we use a dual-channel SD-OCT system combined with CS technology to double the imaging speed. In mode (2), when the spectral resolution of the spectrometer is only half of that used in a single-channel system, the imaging depth can be nearly doubled. We demonstrate the feasibility and effectiveness of the method proposed in this work by imaging a mirror, a fish fin, a fish eye, and an onion. MDPI 2019-09-16 /pmc/articles/PMC6767665/ /pubmed/31527515 http://dx.doi.org/10.3390/s19184006 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Yi, Luying
Sun, Liqun
Zou, Mingli
Hou, Bo
Dual-Channel Spectral Domain Optical Coherence Tomography Based on a Single Spectrometer Using Compressive Sensing
title Dual-Channel Spectral Domain Optical Coherence Tomography Based on a Single Spectrometer Using Compressive Sensing
title_full Dual-Channel Spectral Domain Optical Coherence Tomography Based on a Single Spectrometer Using Compressive Sensing
title_fullStr Dual-Channel Spectral Domain Optical Coherence Tomography Based on a Single Spectrometer Using Compressive Sensing
title_full_unstemmed Dual-Channel Spectral Domain Optical Coherence Tomography Based on a Single Spectrometer Using Compressive Sensing
title_short Dual-Channel Spectral Domain Optical Coherence Tomography Based on a Single Spectrometer Using Compressive Sensing
title_sort dual-channel spectral domain optical coherence tomography based on a single spectrometer using compressive sensing
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6767665/
https://www.ncbi.nlm.nih.gov/pubmed/31527515
http://dx.doi.org/10.3390/s19184006
work_keys_str_mv AT yiluying dualchannelspectraldomainopticalcoherencetomographybasedonasinglespectrometerusingcompressivesensing
AT sunliqun dualchannelspectraldomainopticalcoherencetomographybasedonasinglespectrometerusingcompressivesensing
AT zoumingli dualchannelspectraldomainopticalcoherencetomographybasedonasinglespectrometerusingcompressivesensing
AT houbo dualchannelspectraldomainopticalcoherencetomographybasedonasinglespectrometerusingcompressivesensing