Cargando…
Dual-Channel Spectral Domain Optical Coherence Tomography Based on a Single Spectrometer Using Compressive Sensing
Dual-channel spectral domain optical coherence tomography (SD-OCT) is one of the effective methods for improving imaging depth and imaging speed. In this paper, we design a dual-channel SD-OCT system based on a single spectrometer that can operate in two modes: (1) Increasing imaging speed and (2) e...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6767665/ https://www.ncbi.nlm.nih.gov/pubmed/31527515 http://dx.doi.org/10.3390/s19184006 |
_version_ | 1783454967314513920 |
---|---|
author | Yi, Luying Sun, Liqun Zou, Mingli Hou, Bo |
author_facet | Yi, Luying Sun, Liqun Zou, Mingli Hou, Bo |
author_sort | Yi, Luying |
collection | PubMed |
description | Dual-channel spectral domain optical coherence tomography (SD-OCT) is one of the effective methods for improving imaging depth and imaging speed. In this paper, we design a dual-channel SD-OCT system based on a single spectrometer that can operate in two modes: (1) Increasing imaging speed and (2) expanding imaging depth. An optical path offset is preintroduced between the two channels to separate the two-channel data. However, this offset increases the requirement for the spectral resolution of the spectrometer in mode (1), so compressive sensing (CS) technology is used herein to overcome this problem. Consequently, in mode (1), when the spectral resolution of the spectrometer is the same as that used in the single-channel system, we use a dual-channel SD-OCT system combined with CS technology to double the imaging speed. In mode (2), when the spectral resolution of the spectrometer is only half of that used in a single-channel system, the imaging depth can be nearly doubled. We demonstrate the feasibility and effectiveness of the method proposed in this work by imaging a mirror, a fish fin, a fish eye, and an onion. |
format | Online Article Text |
id | pubmed-6767665 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-67676652019-10-02 Dual-Channel Spectral Domain Optical Coherence Tomography Based on a Single Spectrometer Using Compressive Sensing Yi, Luying Sun, Liqun Zou, Mingli Hou, Bo Sensors (Basel) Article Dual-channel spectral domain optical coherence tomography (SD-OCT) is one of the effective methods for improving imaging depth and imaging speed. In this paper, we design a dual-channel SD-OCT system based on a single spectrometer that can operate in two modes: (1) Increasing imaging speed and (2) expanding imaging depth. An optical path offset is preintroduced between the two channels to separate the two-channel data. However, this offset increases the requirement for the spectral resolution of the spectrometer in mode (1), so compressive sensing (CS) technology is used herein to overcome this problem. Consequently, in mode (1), when the spectral resolution of the spectrometer is the same as that used in the single-channel system, we use a dual-channel SD-OCT system combined with CS technology to double the imaging speed. In mode (2), when the spectral resolution of the spectrometer is only half of that used in a single-channel system, the imaging depth can be nearly doubled. We demonstrate the feasibility and effectiveness of the method proposed in this work by imaging a mirror, a fish fin, a fish eye, and an onion. MDPI 2019-09-16 /pmc/articles/PMC6767665/ /pubmed/31527515 http://dx.doi.org/10.3390/s19184006 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Yi, Luying Sun, Liqun Zou, Mingli Hou, Bo Dual-Channel Spectral Domain Optical Coherence Tomography Based on a Single Spectrometer Using Compressive Sensing |
title | Dual-Channel Spectral Domain Optical Coherence Tomography Based on a Single Spectrometer Using Compressive Sensing |
title_full | Dual-Channel Spectral Domain Optical Coherence Tomography Based on a Single Spectrometer Using Compressive Sensing |
title_fullStr | Dual-Channel Spectral Domain Optical Coherence Tomography Based on a Single Spectrometer Using Compressive Sensing |
title_full_unstemmed | Dual-Channel Spectral Domain Optical Coherence Tomography Based on a Single Spectrometer Using Compressive Sensing |
title_short | Dual-Channel Spectral Domain Optical Coherence Tomography Based on a Single Spectrometer Using Compressive Sensing |
title_sort | dual-channel spectral domain optical coherence tomography based on a single spectrometer using compressive sensing |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6767665/ https://www.ncbi.nlm.nih.gov/pubmed/31527515 http://dx.doi.org/10.3390/s19184006 |
work_keys_str_mv | AT yiluying dualchannelspectraldomainopticalcoherencetomographybasedonasinglespectrometerusingcompressivesensing AT sunliqun dualchannelspectraldomainopticalcoherencetomographybasedonasinglespectrometerusingcompressivesensing AT zoumingli dualchannelspectraldomainopticalcoherencetomographybasedonasinglespectrometerusingcompressivesensing AT houbo dualchannelspectraldomainopticalcoherencetomographybasedonasinglespectrometerusingcompressivesensing |