Cargando…

Thin Magnetically Permeable Targets for Inductive Sensing: Application to Limb Prosthetics

The purpose of this research was to create a thin ferrous polymer composite to be used as a target for inductive sensing in limb prosthetics. Inductive sensors are used to monitor limb-to-socket distance in prosthetic sockets, which reflects socket fit. A styrene–ethylene–ethylene/propylene–styrene...

Descripción completa

Detalles Bibliográficos
Autores principales: Weathersby, Ethan J., Gurrey, Clement J., McLean, Jake B., Sanders, Benjamin N., Larsen, Brian G., Carter, Ryan, Garbini, Joseph L., Sanders, Joan E.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6767675/
https://www.ncbi.nlm.nih.gov/pubmed/31546816
http://dx.doi.org/10.3390/s19184041
_version_ 1783454969756647424
author Weathersby, Ethan J.
Gurrey, Clement J.
McLean, Jake B.
Sanders, Benjamin N.
Larsen, Brian G.
Carter, Ryan
Garbini, Joseph L.
Sanders, Joan E.
author_facet Weathersby, Ethan J.
Gurrey, Clement J.
McLean, Jake B.
Sanders, Benjamin N.
Larsen, Brian G.
Carter, Ryan
Garbini, Joseph L.
Sanders, Joan E.
author_sort Weathersby, Ethan J.
collection PubMed
description The purpose of this research was to create a thin ferrous polymer composite to be used as a target for inductive sensing in limb prosthetics. Inductive sensors are used to monitor limb-to-socket distance in prosthetic sockets, which reflects socket fit. A styrene–ethylene–ethylene/propylene–styrene (SEEPS) polymer was mixed with iron powder at three concentrations (75, 77, 85 wt%), and thin disk-shaped samples were fabricated (0.50, 0,75, 1.00 mm thickness). For 85 wt% samples of 0.50 mm thickness, which proved the best combination of high signal strength and low target volume, inductive sensor sensitivity ranged from 3.2E5 counts/mm at 0.00–1.00 mm distances to 7.2E4 counts/mm at 4.00–5.00 mm distances. The application of compressive stress (up to 425 kPa) introduced an absolute measurement error of less than 3.3 μm. Tensile elasticity was 282 kPa, which is comparable to that of commercial elastomeric liners. Durability testing in the shoe of an able-bodied participant demonstrated a change in calibration coefficient of less than 3.8% over two weeks of wear. The ferrous polymer composite may facilitate the development of automatically adjusting sockets that use limb-to-socket distance measurement for feedback control.
format Online
Article
Text
id pubmed-6767675
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-67676752019-10-02 Thin Magnetically Permeable Targets for Inductive Sensing: Application to Limb Prosthetics Weathersby, Ethan J. Gurrey, Clement J. McLean, Jake B. Sanders, Benjamin N. Larsen, Brian G. Carter, Ryan Garbini, Joseph L. Sanders, Joan E. Sensors (Basel) Article The purpose of this research was to create a thin ferrous polymer composite to be used as a target for inductive sensing in limb prosthetics. Inductive sensors are used to monitor limb-to-socket distance in prosthetic sockets, which reflects socket fit. A styrene–ethylene–ethylene/propylene–styrene (SEEPS) polymer was mixed with iron powder at three concentrations (75, 77, 85 wt%), and thin disk-shaped samples were fabricated (0.50, 0,75, 1.00 mm thickness). For 85 wt% samples of 0.50 mm thickness, which proved the best combination of high signal strength and low target volume, inductive sensor sensitivity ranged from 3.2E5 counts/mm at 0.00–1.00 mm distances to 7.2E4 counts/mm at 4.00–5.00 mm distances. The application of compressive stress (up to 425 kPa) introduced an absolute measurement error of less than 3.3 μm. Tensile elasticity was 282 kPa, which is comparable to that of commercial elastomeric liners. Durability testing in the shoe of an able-bodied participant demonstrated a change in calibration coefficient of less than 3.8% over two weeks of wear. The ferrous polymer composite may facilitate the development of automatically adjusting sockets that use limb-to-socket distance measurement for feedback control. MDPI 2019-09-19 /pmc/articles/PMC6767675/ /pubmed/31546816 http://dx.doi.org/10.3390/s19184041 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Weathersby, Ethan J.
Gurrey, Clement J.
McLean, Jake B.
Sanders, Benjamin N.
Larsen, Brian G.
Carter, Ryan
Garbini, Joseph L.
Sanders, Joan E.
Thin Magnetically Permeable Targets for Inductive Sensing: Application to Limb Prosthetics
title Thin Magnetically Permeable Targets for Inductive Sensing: Application to Limb Prosthetics
title_full Thin Magnetically Permeable Targets for Inductive Sensing: Application to Limb Prosthetics
title_fullStr Thin Magnetically Permeable Targets for Inductive Sensing: Application to Limb Prosthetics
title_full_unstemmed Thin Magnetically Permeable Targets for Inductive Sensing: Application to Limb Prosthetics
title_short Thin Magnetically Permeable Targets for Inductive Sensing: Application to Limb Prosthetics
title_sort thin magnetically permeable targets for inductive sensing: application to limb prosthetics
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6767675/
https://www.ncbi.nlm.nih.gov/pubmed/31546816
http://dx.doi.org/10.3390/s19184041
work_keys_str_mv AT weathersbyethanj thinmagneticallypermeabletargetsforinductivesensingapplicationtolimbprosthetics
AT gurreyclementj thinmagneticallypermeabletargetsforinductivesensingapplicationtolimbprosthetics
AT mcleanjakeb thinmagneticallypermeabletargetsforinductivesensingapplicationtolimbprosthetics
AT sandersbenjaminn thinmagneticallypermeabletargetsforinductivesensingapplicationtolimbprosthetics
AT larsenbriang thinmagneticallypermeabletargetsforinductivesensingapplicationtolimbprosthetics
AT carterryan thinmagneticallypermeabletargetsforinductivesensingapplicationtolimbprosthetics
AT garbinijosephl thinmagneticallypermeabletargetsforinductivesensingapplicationtolimbprosthetics
AT sandersjoane thinmagneticallypermeabletargetsforinductivesensingapplicationtolimbprosthetics