Cargando…
How Does Breathing Frequency Affect the Performance of an N95 Filtering Facepiece Respirator and a Surgical Mask Against Surrogates of Viral Particles?
Breathing frequency (breaths/min) differs among individuals and levels of physical activity. Particles enter respirators through two principle penetration pathways: faceseal leakage and filter penetration. However, it is unknown how breathing frequency affects the overall performance of N95 filterin...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Taylor & Francis
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6768065/ https://www.ncbi.nlm.nih.gov/pubmed/24521067 http://dx.doi.org/10.1080/15459624.2013.848037 |
_version_ | 1783455049836396544 |
---|---|
author | He, Xinjian Reponen, Tiina McKay, Roy Grinshpun, Sergey A. |
author_facet | He, Xinjian Reponen, Tiina McKay, Roy Grinshpun, Sergey A. |
author_sort | He, Xinjian |
collection | PubMed |
description | Breathing frequency (breaths/min) differs among individuals and levels of physical activity. Particles enter respirators through two principle penetration pathways: faceseal leakage and filter penetration. However, it is unknown how breathing frequency affects the overall performance of N95 filtering facepiece respirators (FFRs) and surgical masks (SMs) against viral particles, as well as other health-relevant submicrometer particles. A FFR and SM were tested on a breathing manikin at four mean inspiratory flows (MIFs) (15, 30, 55, and 85 L/min) and five breathing frequencies (10, 15, 20, 25, and 30 breaths/min). Filter penetration (P(filter)) and total inward leakage (TIL) were determined for the tested respiratory protection devices against sodium chloride (NaCl) aerosol particles in the size range of 20 to 500 nm. “Faceseal leakage-to-filter” (FLTF) penetration ratios were calculated. Both MIF and breathing frequency showed significant effects (p < 0.05) on P(filter) and TIL. Increasing breathing frequency increased TIL for the N95 FFR whereas no clear trends were observed for the SM. Increasing MIF increased P(filter) and decreased TIL resulting in decreasing FLTF ratio. Most of FLTF ratios were >1, suggesting that the faceseal leakage was the primary particle penetration pathway at various breathing frequencies. Breathing frequency is another factor (besides MIF) that can significantly affect the performance of N95 FFRs, with higher breathing frequencies increasing TIL. No consistent trend of increase or decrease of TIL with either MIF or breathing frequency was observed for the tested SM. To potentially extend these findings beyond the manikin/breathing system used, future studies are needed to fully understand the mechanism causing the breathing frequency effect on the performance of respiratory protection devices on human subjects. |
format | Online Article Text |
id | pubmed-6768065 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Taylor & Francis |
record_format | MEDLINE/PubMed |
spelling | pubmed-67680652019-09-30 How Does Breathing Frequency Affect the Performance of an N95 Filtering Facepiece Respirator and a Surgical Mask Against Surrogates of Viral Particles? He, Xinjian Reponen, Tiina McKay, Roy Grinshpun, Sergey A. J Occup Environ Hyg Article Breathing frequency (breaths/min) differs among individuals and levels of physical activity. Particles enter respirators through two principle penetration pathways: faceseal leakage and filter penetration. However, it is unknown how breathing frequency affects the overall performance of N95 filtering facepiece respirators (FFRs) and surgical masks (SMs) against viral particles, as well as other health-relevant submicrometer particles. A FFR and SM were tested on a breathing manikin at four mean inspiratory flows (MIFs) (15, 30, 55, and 85 L/min) and five breathing frequencies (10, 15, 20, 25, and 30 breaths/min). Filter penetration (P(filter)) and total inward leakage (TIL) were determined for the tested respiratory protection devices against sodium chloride (NaCl) aerosol particles in the size range of 20 to 500 nm. “Faceseal leakage-to-filter” (FLTF) penetration ratios were calculated. Both MIF and breathing frequency showed significant effects (p < 0.05) on P(filter) and TIL. Increasing breathing frequency increased TIL for the N95 FFR whereas no clear trends were observed for the SM. Increasing MIF increased P(filter) and decreased TIL resulting in decreasing FLTF ratio. Most of FLTF ratios were >1, suggesting that the faceseal leakage was the primary particle penetration pathway at various breathing frequencies. Breathing frequency is another factor (besides MIF) that can significantly affect the performance of N95 FFRs, with higher breathing frequencies increasing TIL. No consistent trend of increase or decrease of TIL with either MIF or breathing frequency was observed for the tested SM. To potentially extend these findings beyond the manikin/breathing system used, future studies are needed to fully understand the mechanism causing the breathing frequency effect on the performance of respiratory protection devices on human subjects. Taylor & Francis 2014-02-12 /pmc/articles/PMC6768065/ /pubmed/24521067 http://dx.doi.org/10.1080/15459624.2013.848037 Text en Copyright © 2014 JOEH, LLC This article is made available via the PMC Open Access Subset for unrestricted re-use and analyses in any form or by any means with acknowledgement of the original source. These permissions are granted for the duration of the COVID-19 pandemic or until permissions are revoked in writing. Upon expiration of these permissions, PMC is granted a perpetual license to make this article available via PMC and Europe PMC, consistent with existing copyright protections. |
spellingShingle | Article He, Xinjian Reponen, Tiina McKay, Roy Grinshpun, Sergey A. How Does Breathing Frequency Affect the Performance of an N95 Filtering Facepiece Respirator and a Surgical Mask Against Surrogates of Viral Particles? |
title | How Does Breathing Frequency Affect the Performance of an N95 Filtering
Facepiece Respirator and a Surgical Mask Against Surrogates of Viral
Particles? |
title_full | How Does Breathing Frequency Affect the Performance of an N95 Filtering
Facepiece Respirator and a Surgical Mask Against Surrogates of Viral
Particles? |
title_fullStr | How Does Breathing Frequency Affect the Performance of an N95 Filtering
Facepiece Respirator and a Surgical Mask Against Surrogates of Viral
Particles? |
title_full_unstemmed | How Does Breathing Frequency Affect the Performance of an N95 Filtering
Facepiece Respirator and a Surgical Mask Against Surrogates of Viral
Particles? |
title_short | How Does Breathing Frequency Affect the Performance of an N95 Filtering
Facepiece Respirator and a Surgical Mask Against Surrogates of Viral
Particles? |
title_sort | how does breathing frequency affect the performance of an n95 filtering
facepiece respirator and a surgical mask against surrogates of viral
particles? |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6768065/ https://www.ncbi.nlm.nih.gov/pubmed/24521067 http://dx.doi.org/10.1080/15459624.2013.848037 |
work_keys_str_mv | AT hexinjian howdoesbreathingfrequencyaffecttheperformanceofann95filteringfacepiecerespiratorandasurgicalmaskagainstsurrogatesofviralparticles AT reponentiina howdoesbreathingfrequencyaffecttheperformanceofann95filteringfacepiecerespiratorandasurgicalmaskagainstsurrogatesofviralparticles AT mckayroy howdoesbreathingfrequencyaffecttheperformanceofann95filteringfacepiecerespiratorandasurgicalmaskagainstsurrogatesofviralparticles AT grinshpunsergeya howdoesbreathingfrequencyaffecttheperformanceofann95filteringfacepiecerespiratorandasurgicalmaskagainstsurrogatesofviralparticles |