Cargando…

Contrast Echocardiography in two-dimensional left ventricular measurements: comparison with 256-row multi-detector computed tomography as a reference standard in Beagles

Unenhanced echocardiography (UE), commonly used in veterinary practice, is limited by left ventricular (LV) foreshortening and observer dependency. Contrast echocardiography (CE) was used to compare two-dimensional (2D) LV measurements made using UE and 256-row multi-detector computed tomography (MD...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Jaehwan, Kim, Soyoung, Lee, Yeonhea, Yoon, Hakyoung, Eom, Kidong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society of Veterinary Science 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6769328/
https://www.ncbi.nlm.nih.gov/pubmed/31565888
http://dx.doi.org/10.4142/jvs.2019.20.e45
_version_ 1783455218655035392
author Kim, Jaehwan
Kim, Soyoung
Lee, Yeonhea
Yoon, Hakyoung
Eom, Kidong
author_facet Kim, Jaehwan
Kim, Soyoung
Lee, Yeonhea
Yoon, Hakyoung
Eom, Kidong
author_sort Kim, Jaehwan
collection PubMed
description Unenhanced echocardiography (UE), commonly used in veterinary practice, is limited by left ventricular (LV) foreshortening and observer dependency. Contrast echocardiography (CE) was used to compare two-dimensional (2D) LV measurements made using UE and 256-row multi-detector computed tomography (MDCT) as a reference standard. Seven healthy beagle dogs were evaluated in this study. Measurements obtained using CE, including LV wall thickness, internal diameter, and longitudinal and transverse length, were significantly greater than those obtained using UE. Measurements of LV internal dimension in diastole (LVIDd) and systole (LVIDs) were significantly larger with CE compared UE. Regardless of the cardiac cycle, LV longitudinal (LVLd and LVLs) and transverse diameter (LVTDd and LVTDs) measurements were significantly different with CE and approximated values from MDCT. Among automatically calculated parameters, LV end-systolic volume and the relative wall thickness were significantly different between UE and CE. In CE, the correlation coefficients of 4 major parameters (r = 0.87 in LVIDd; 0.91 in LVIDs; 0.87 in LVLd; and 0.81 in LVLs) showed higher values compared to the UE (r = 0.68 in LVIDd, 0.71 in LVIDs, 0.69 in LVLd, and 0.35 in LVLs). Inter-observer agreement was highest for MDCT and higher for CE than UE. In conclusion, CE is more accurate and reproducible than UE in assessing 2D LV measurements and can overcome the limitations of UE including LV foreshortening and high observer dependency.
format Online
Article
Text
id pubmed-6769328
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher The Korean Society of Veterinary Science
record_format MEDLINE/PubMed
spelling pubmed-67693282019-10-09 Contrast Echocardiography in two-dimensional left ventricular measurements: comparison with 256-row multi-detector computed tomography as a reference standard in Beagles Kim, Jaehwan Kim, Soyoung Lee, Yeonhea Yoon, Hakyoung Eom, Kidong J Vet Sci Original Article Unenhanced echocardiography (UE), commonly used in veterinary practice, is limited by left ventricular (LV) foreshortening and observer dependency. Contrast echocardiography (CE) was used to compare two-dimensional (2D) LV measurements made using UE and 256-row multi-detector computed tomography (MDCT) as a reference standard. Seven healthy beagle dogs were evaluated in this study. Measurements obtained using CE, including LV wall thickness, internal diameter, and longitudinal and transverse length, were significantly greater than those obtained using UE. Measurements of LV internal dimension in diastole (LVIDd) and systole (LVIDs) were significantly larger with CE compared UE. Regardless of the cardiac cycle, LV longitudinal (LVLd and LVLs) and transverse diameter (LVTDd and LVTDs) measurements were significantly different with CE and approximated values from MDCT. Among automatically calculated parameters, LV end-systolic volume and the relative wall thickness were significantly different between UE and CE. In CE, the correlation coefficients of 4 major parameters (r = 0.87 in LVIDd; 0.91 in LVIDs; 0.87 in LVLd; and 0.81 in LVLs) showed higher values compared to the UE (r = 0.68 in LVIDd, 0.71 in LVIDs, 0.69 in LVLd, and 0.35 in LVLs). Inter-observer agreement was highest for MDCT and higher for CE than UE. In conclusion, CE is more accurate and reproducible than UE in assessing 2D LV measurements and can overcome the limitations of UE including LV foreshortening and high observer dependency. The Korean Society of Veterinary Science 2019-09 2019-08-22 /pmc/articles/PMC6769328/ /pubmed/31565888 http://dx.doi.org/10.4142/jvs.2019.20.e45 Text en © 2019 The Korean Society of Veterinary Science https://creativecommons.org/licenses/by-nc/4.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (https://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Kim, Jaehwan
Kim, Soyoung
Lee, Yeonhea
Yoon, Hakyoung
Eom, Kidong
Contrast Echocardiography in two-dimensional left ventricular measurements: comparison with 256-row multi-detector computed tomography as a reference standard in Beagles
title Contrast Echocardiography in two-dimensional left ventricular measurements: comparison with 256-row multi-detector computed tomography as a reference standard in Beagles
title_full Contrast Echocardiography in two-dimensional left ventricular measurements: comparison with 256-row multi-detector computed tomography as a reference standard in Beagles
title_fullStr Contrast Echocardiography in two-dimensional left ventricular measurements: comparison with 256-row multi-detector computed tomography as a reference standard in Beagles
title_full_unstemmed Contrast Echocardiography in two-dimensional left ventricular measurements: comparison with 256-row multi-detector computed tomography as a reference standard in Beagles
title_short Contrast Echocardiography in two-dimensional left ventricular measurements: comparison with 256-row multi-detector computed tomography as a reference standard in Beagles
title_sort contrast echocardiography in two-dimensional left ventricular measurements: comparison with 256-row multi-detector computed tomography as a reference standard in beagles
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6769328/
https://www.ncbi.nlm.nih.gov/pubmed/31565888
http://dx.doi.org/10.4142/jvs.2019.20.e45
work_keys_str_mv AT kimjaehwan contrastechocardiographyintwodimensionalleftventricularmeasurementscomparisonwith256rowmultidetectorcomputedtomographyasareferencestandardinbeagles
AT kimsoyoung contrastechocardiographyintwodimensionalleftventricularmeasurementscomparisonwith256rowmultidetectorcomputedtomographyasareferencestandardinbeagles
AT leeyeonhea contrastechocardiographyintwodimensionalleftventricularmeasurementscomparisonwith256rowmultidetectorcomputedtomographyasareferencestandardinbeagles
AT yoonhakyoung contrastechocardiographyintwodimensionalleftventricularmeasurementscomparisonwith256rowmultidetectorcomputedtomographyasareferencestandardinbeagles
AT eomkidong contrastechocardiographyintwodimensionalleftventricularmeasurementscomparisonwith256rowmultidetectorcomputedtomographyasareferencestandardinbeagles