Cargando…
The value of echocardiography and Doppler in the prediction of fetal demise after laser coagulation for TTTS: A systematic review and meta‐analysis
This study aimed to investigate the value of echocardiography and Doppler before fetoscopic laser coagulation for twin‐twin transfusion syndrome (TTTS) in the prediction of intrauterine fetal demise (IUFD). We performed a systematic review and meta‐analysis to compare preoperative parameters between...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6771838/ https://www.ncbi.nlm.nih.gov/pubmed/31237967 http://dx.doi.org/10.1002/pd.5511 |
_version_ | 1783455779385245696 |
---|---|
author | Gijtenbeek, Manon Eschbach, Sanne J. Middeldorp, Johanna M. Klumper, Frans J.C.M. Slaghekke, Femke Oepkes, Dick Haak, Monique C. |
author_facet | Gijtenbeek, Manon Eschbach, Sanne J. Middeldorp, Johanna M. Klumper, Frans J.C.M. Slaghekke, Femke Oepkes, Dick Haak, Monique C. |
author_sort | Gijtenbeek, Manon |
collection | PubMed |
description | This study aimed to investigate the value of echocardiography and Doppler before fetoscopic laser coagulation for twin‐twin transfusion syndrome (TTTS) in the prediction of intrauterine fetal demise (IUFD). We performed a systematic review and meta‐analysis to compare preoperative parameters between fetuses with and without demise after laser surgery. Eighteen studies were included. Recipient twins have an increased risk of demise in case of preoperative absent/reversed flow (A/REDF) in the umbilical artery (odds ratio [OR] 2.76, 95% confidence interval [CI], 1.78‐4.28), absent or reversed a‐wave in the ductus venosus (OR 2.32, 95% CI, 1.70‐3.16), or a middle cerebral artery peak systolic velocity > 1.5 multiples of the median (MoM) (OR 7.59, 95% CI, 2.56‐22.46). In donors, only A/REDF in the umbilical artery (OR 3.40, 95% CI, 2.68‐4.32) and absent or reversed a‐wave in the ductus venosus (OR 1.66, 95% CI, 1.12‐2.47) were associated with IUFD. No association was found between donor‐IUFD and preoperative myocardial performance index (MPI). Two studies found an association between abnormal MPI and recipient demise. With this study, we have identified a set of preoperative Doppler parameters predictive of fetal demise after laser surgery. More research is needed to assess the utility of preoperative echocardiographic parameters such as the MPI in predicting IUFD. |
format | Online Article Text |
id | pubmed-6771838 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-67718382019-10-07 The value of echocardiography and Doppler in the prediction of fetal demise after laser coagulation for TTTS: A systematic review and meta‐analysis Gijtenbeek, Manon Eschbach, Sanne J. Middeldorp, Johanna M. Klumper, Frans J.C.M. Slaghekke, Femke Oepkes, Dick Haak, Monique C. Prenat Diagn Review This study aimed to investigate the value of echocardiography and Doppler before fetoscopic laser coagulation for twin‐twin transfusion syndrome (TTTS) in the prediction of intrauterine fetal demise (IUFD). We performed a systematic review and meta‐analysis to compare preoperative parameters between fetuses with and without demise after laser surgery. Eighteen studies were included. Recipient twins have an increased risk of demise in case of preoperative absent/reversed flow (A/REDF) in the umbilical artery (odds ratio [OR] 2.76, 95% confidence interval [CI], 1.78‐4.28), absent or reversed a‐wave in the ductus venosus (OR 2.32, 95% CI, 1.70‐3.16), or a middle cerebral artery peak systolic velocity > 1.5 multiples of the median (MoM) (OR 7.59, 95% CI, 2.56‐22.46). In donors, only A/REDF in the umbilical artery (OR 3.40, 95% CI, 2.68‐4.32) and absent or reversed a‐wave in the ductus venosus (OR 1.66, 95% CI, 1.12‐2.47) were associated with IUFD. No association was found between donor‐IUFD and preoperative myocardial performance index (MPI). Two studies found an association between abnormal MPI and recipient demise. With this study, we have identified a set of preoperative Doppler parameters predictive of fetal demise after laser surgery. More research is needed to assess the utility of preoperative echocardiographic parameters such as the MPI in predicting IUFD. John Wiley and Sons Inc. 2019-07-17 2019-09 /pmc/articles/PMC6771838/ /pubmed/31237967 http://dx.doi.org/10.1002/pd.5511 Text en © 2019 The Authors. Prenatal Diagnosis Published by John Wiley & Sons Ltd This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made. |
spellingShingle | Review Gijtenbeek, Manon Eschbach, Sanne J. Middeldorp, Johanna M. Klumper, Frans J.C.M. Slaghekke, Femke Oepkes, Dick Haak, Monique C. The value of echocardiography and Doppler in the prediction of fetal demise after laser coagulation for TTTS: A systematic review and meta‐analysis |
title | The value of echocardiography and Doppler in the prediction of fetal demise after laser coagulation for TTTS: A systematic review and meta‐analysis |
title_full | The value of echocardiography and Doppler in the prediction of fetal demise after laser coagulation for TTTS: A systematic review and meta‐analysis |
title_fullStr | The value of echocardiography and Doppler in the prediction of fetal demise after laser coagulation for TTTS: A systematic review and meta‐analysis |
title_full_unstemmed | The value of echocardiography and Doppler in the prediction of fetal demise after laser coagulation for TTTS: A systematic review and meta‐analysis |
title_short | The value of echocardiography and Doppler in the prediction of fetal demise after laser coagulation for TTTS: A systematic review and meta‐analysis |
title_sort | value of echocardiography and doppler in the prediction of fetal demise after laser coagulation for ttts: a systematic review and meta‐analysis |
topic | Review |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6771838/ https://www.ncbi.nlm.nih.gov/pubmed/31237967 http://dx.doi.org/10.1002/pd.5511 |
work_keys_str_mv | AT gijtenbeekmanon thevalueofechocardiographyanddopplerinthepredictionoffetaldemiseafterlasercoagulationfortttsasystematicreviewandmetaanalysis AT eschbachsannej thevalueofechocardiographyanddopplerinthepredictionoffetaldemiseafterlasercoagulationfortttsasystematicreviewandmetaanalysis AT middeldorpjohannam thevalueofechocardiographyanddopplerinthepredictionoffetaldemiseafterlasercoagulationfortttsasystematicreviewandmetaanalysis AT klumperfransjcm thevalueofechocardiographyanddopplerinthepredictionoffetaldemiseafterlasercoagulationfortttsasystematicreviewandmetaanalysis AT slaghekkefemke thevalueofechocardiographyanddopplerinthepredictionoffetaldemiseafterlasercoagulationfortttsasystematicreviewandmetaanalysis AT oepkesdick thevalueofechocardiographyanddopplerinthepredictionoffetaldemiseafterlasercoagulationfortttsasystematicreviewandmetaanalysis AT haakmoniquec thevalueofechocardiographyanddopplerinthepredictionoffetaldemiseafterlasercoagulationfortttsasystematicreviewandmetaanalysis AT gijtenbeekmanon valueofechocardiographyanddopplerinthepredictionoffetaldemiseafterlasercoagulationfortttsasystematicreviewandmetaanalysis AT eschbachsannej valueofechocardiographyanddopplerinthepredictionoffetaldemiseafterlasercoagulationfortttsasystematicreviewandmetaanalysis AT middeldorpjohannam valueofechocardiographyanddopplerinthepredictionoffetaldemiseafterlasercoagulationfortttsasystematicreviewandmetaanalysis AT klumperfransjcm valueofechocardiographyanddopplerinthepredictionoffetaldemiseafterlasercoagulationfortttsasystematicreviewandmetaanalysis AT slaghekkefemke valueofechocardiographyanddopplerinthepredictionoffetaldemiseafterlasercoagulationfortttsasystematicreviewandmetaanalysis AT oepkesdick valueofechocardiographyanddopplerinthepredictionoffetaldemiseafterlasercoagulationfortttsasystematicreviewandmetaanalysis AT haakmoniquec valueofechocardiographyanddopplerinthepredictionoffetaldemiseafterlasercoagulationfortttsasystematicreviewandmetaanalysis |