Cargando…

The value of echocardiography and Doppler in the prediction of fetal demise after laser coagulation for TTTS: A systematic review and meta‐analysis

This study aimed to investigate the value of echocardiography and Doppler before fetoscopic laser coagulation for twin‐twin transfusion syndrome (TTTS) in the prediction of intrauterine fetal demise (IUFD). We performed a systematic review and meta‐analysis to compare preoperative parameters between...

Descripción completa

Detalles Bibliográficos
Autores principales: Gijtenbeek, Manon, Eschbach, Sanne J., Middeldorp, Johanna M., Klumper, Frans J.C.M., Slaghekke, Femke, Oepkes, Dick, Haak, Monique C.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6771838/
https://www.ncbi.nlm.nih.gov/pubmed/31237967
http://dx.doi.org/10.1002/pd.5511
_version_ 1783455779385245696
author Gijtenbeek, Manon
Eschbach, Sanne J.
Middeldorp, Johanna M.
Klumper, Frans J.C.M.
Slaghekke, Femke
Oepkes, Dick
Haak, Monique C.
author_facet Gijtenbeek, Manon
Eschbach, Sanne J.
Middeldorp, Johanna M.
Klumper, Frans J.C.M.
Slaghekke, Femke
Oepkes, Dick
Haak, Monique C.
author_sort Gijtenbeek, Manon
collection PubMed
description This study aimed to investigate the value of echocardiography and Doppler before fetoscopic laser coagulation for twin‐twin transfusion syndrome (TTTS) in the prediction of intrauterine fetal demise (IUFD). We performed a systematic review and meta‐analysis to compare preoperative parameters between fetuses with and without demise after laser surgery. Eighteen studies were included. Recipient twins have an increased risk of demise in case of preoperative absent/reversed flow (A/REDF) in the umbilical artery (odds ratio [OR] 2.76, 95% confidence interval [CI], 1.78‐4.28), absent or reversed a‐wave in the ductus venosus (OR 2.32, 95% CI, 1.70‐3.16), or a middle cerebral artery peak systolic velocity > 1.5 multiples of the median (MoM) (OR 7.59, 95% CI, 2.56‐22.46). In donors, only A/REDF in the umbilical artery (OR 3.40, 95% CI, 2.68‐4.32) and absent or reversed a‐wave in the ductus venosus (OR 1.66, 95% CI, 1.12‐2.47) were associated with IUFD. No association was found between donor‐IUFD and preoperative myocardial performance index (MPI). Two studies found an association between abnormal MPI and recipient demise. With this study, we have identified a set of preoperative Doppler parameters predictive of fetal demise after laser surgery. More research is needed to assess the utility of preoperative echocardiographic parameters such as the MPI in predicting IUFD.
format Online
Article
Text
id pubmed-6771838
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-67718382019-10-07 The value of echocardiography and Doppler in the prediction of fetal demise after laser coagulation for TTTS: A systematic review and meta‐analysis Gijtenbeek, Manon Eschbach, Sanne J. Middeldorp, Johanna M. Klumper, Frans J.C.M. Slaghekke, Femke Oepkes, Dick Haak, Monique C. Prenat Diagn Review This study aimed to investigate the value of echocardiography and Doppler before fetoscopic laser coagulation for twin‐twin transfusion syndrome (TTTS) in the prediction of intrauterine fetal demise (IUFD). We performed a systematic review and meta‐analysis to compare preoperative parameters between fetuses with and without demise after laser surgery. Eighteen studies were included. Recipient twins have an increased risk of demise in case of preoperative absent/reversed flow (A/REDF) in the umbilical artery (odds ratio [OR] 2.76, 95% confidence interval [CI], 1.78‐4.28), absent or reversed a‐wave in the ductus venosus (OR 2.32, 95% CI, 1.70‐3.16), or a middle cerebral artery peak systolic velocity > 1.5 multiples of the median (MoM) (OR 7.59, 95% CI, 2.56‐22.46). In donors, only A/REDF in the umbilical artery (OR 3.40, 95% CI, 2.68‐4.32) and absent or reversed a‐wave in the ductus venosus (OR 1.66, 95% CI, 1.12‐2.47) were associated with IUFD. No association was found between donor‐IUFD and preoperative myocardial performance index (MPI). Two studies found an association between abnormal MPI and recipient demise. With this study, we have identified a set of preoperative Doppler parameters predictive of fetal demise after laser surgery. More research is needed to assess the utility of preoperative echocardiographic parameters such as the MPI in predicting IUFD. John Wiley and Sons Inc. 2019-07-17 2019-09 /pmc/articles/PMC6771838/ /pubmed/31237967 http://dx.doi.org/10.1002/pd.5511 Text en © 2019 The Authors. Prenatal Diagnosis Published by John Wiley & Sons Ltd This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made.
spellingShingle Review
Gijtenbeek, Manon
Eschbach, Sanne J.
Middeldorp, Johanna M.
Klumper, Frans J.C.M.
Slaghekke, Femke
Oepkes, Dick
Haak, Monique C.
The value of echocardiography and Doppler in the prediction of fetal demise after laser coagulation for TTTS: A systematic review and meta‐analysis
title The value of echocardiography and Doppler in the prediction of fetal demise after laser coagulation for TTTS: A systematic review and meta‐analysis
title_full The value of echocardiography and Doppler in the prediction of fetal demise after laser coagulation for TTTS: A systematic review and meta‐analysis
title_fullStr The value of echocardiography and Doppler in the prediction of fetal demise after laser coagulation for TTTS: A systematic review and meta‐analysis
title_full_unstemmed The value of echocardiography and Doppler in the prediction of fetal demise after laser coagulation for TTTS: A systematic review and meta‐analysis
title_short The value of echocardiography and Doppler in the prediction of fetal demise after laser coagulation for TTTS: A systematic review and meta‐analysis
title_sort value of echocardiography and doppler in the prediction of fetal demise after laser coagulation for ttts: a systematic review and meta‐analysis
topic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6771838/
https://www.ncbi.nlm.nih.gov/pubmed/31237967
http://dx.doi.org/10.1002/pd.5511
work_keys_str_mv AT gijtenbeekmanon thevalueofechocardiographyanddopplerinthepredictionoffetaldemiseafterlasercoagulationfortttsasystematicreviewandmetaanalysis
AT eschbachsannej thevalueofechocardiographyanddopplerinthepredictionoffetaldemiseafterlasercoagulationfortttsasystematicreviewandmetaanalysis
AT middeldorpjohannam thevalueofechocardiographyanddopplerinthepredictionoffetaldemiseafterlasercoagulationfortttsasystematicreviewandmetaanalysis
AT klumperfransjcm thevalueofechocardiographyanddopplerinthepredictionoffetaldemiseafterlasercoagulationfortttsasystematicreviewandmetaanalysis
AT slaghekkefemke thevalueofechocardiographyanddopplerinthepredictionoffetaldemiseafterlasercoagulationfortttsasystematicreviewandmetaanalysis
AT oepkesdick thevalueofechocardiographyanddopplerinthepredictionoffetaldemiseafterlasercoagulationfortttsasystematicreviewandmetaanalysis
AT haakmoniquec thevalueofechocardiographyanddopplerinthepredictionoffetaldemiseafterlasercoagulationfortttsasystematicreviewandmetaanalysis
AT gijtenbeekmanon valueofechocardiographyanddopplerinthepredictionoffetaldemiseafterlasercoagulationfortttsasystematicreviewandmetaanalysis
AT eschbachsannej valueofechocardiographyanddopplerinthepredictionoffetaldemiseafterlasercoagulationfortttsasystematicreviewandmetaanalysis
AT middeldorpjohannam valueofechocardiographyanddopplerinthepredictionoffetaldemiseafterlasercoagulationfortttsasystematicreviewandmetaanalysis
AT klumperfransjcm valueofechocardiographyanddopplerinthepredictionoffetaldemiseafterlasercoagulationfortttsasystematicreviewandmetaanalysis
AT slaghekkefemke valueofechocardiographyanddopplerinthepredictionoffetaldemiseafterlasercoagulationfortttsasystematicreviewandmetaanalysis
AT oepkesdick valueofechocardiographyanddopplerinthepredictionoffetaldemiseafterlasercoagulationfortttsasystematicreviewandmetaanalysis
AT haakmoniquec valueofechocardiographyanddopplerinthepredictionoffetaldemiseafterlasercoagulationfortttsasystematicreviewandmetaanalysis