Cargando…
Measurement of extravascular lung water to diagnose severe reperfusion lung injury following pulmonary endarterectomy: a prospective cohort clinical validation study
The measurement of extravascular lung water is a relatively new technology which has not yet been well validated as a clinically useful tool. We studied its utility in patients undergoing pulmonary endarterectomy as they frequently suffer reperfusion lung injury and associated oedematous lungs. Such...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6772184/ https://www.ncbi.nlm.nih.gov/pubmed/31273760 http://dx.doi.org/10.1111/anae.14744 |
_version_ | 1783455856202874880 |
---|---|
author | Butchart, A. G. Zochios, V. Villar, S. S. Jones, N. L. Curry, S. Agrawal, B. Jenkins, D. P. Klein, A. A. |
author_facet | Butchart, A. G. Zochios, V. Villar, S. S. Jones, N. L. Curry, S. Agrawal, B. Jenkins, D. P. Klein, A. A. |
author_sort | Butchart, A. G. |
collection | PubMed |
description | The measurement of extravascular lung water is a relatively new technology which has not yet been well validated as a clinically useful tool. We studied its utility in patients undergoing pulmonary endarterectomy as they frequently suffer reperfusion lung injury and associated oedematous lungs. Such patients are therefore ideal for evaluating this new monitor. We performed a prospective observational cohort study during which extravascular lung water index measurements were taken before and immediately after surgery and postoperatively in intensive care. Data were analysed for 57 patients; 21 patients (37%) experienced severe reperfusion lung injury. The first extravascular lung water index measurement after cardiopulmonary bypass failed to predict severe reperfusion lung injury, area under the receiver operating characteristic curve 0.59 (95%CI 0.44–0.74). On intensive care, extravascular lung water index correlated most strongly at 36 h, area under the receiver operating characteristic curve 0.90 (95%CI 0.80–1.00). Peri‐operative extravascular lung water index is not a useful measure to predict severe reperfusion lung injury after pulmonary endarterectomy, however, it does allow monitoring and measurement during the postoperative period. This study implies that extravascular lung water index can be used to directly assess pulmonary fluid overload and that monitoring patients by measuring extravascular lung water index during their intensive care stay is useful and correlates with their clinical course. This may allow directed, pre‐empted therapy to attenuate the effects and improve patient outcomes and should prompt further studies. |
format | Online Article Text |
id | pubmed-6772184 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-67721842019-10-07 Measurement of extravascular lung water to diagnose severe reperfusion lung injury following pulmonary endarterectomy: a prospective cohort clinical validation study Butchart, A. G. Zochios, V. Villar, S. S. Jones, N. L. Curry, S. Agrawal, B. Jenkins, D. P. Klein, A. A. Anaesthesia Original Articles The measurement of extravascular lung water is a relatively new technology which has not yet been well validated as a clinically useful tool. We studied its utility in patients undergoing pulmonary endarterectomy as they frequently suffer reperfusion lung injury and associated oedematous lungs. Such patients are therefore ideal for evaluating this new monitor. We performed a prospective observational cohort study during which extravascular lung water index measurements were taken before and immediately after surgery and postoperatively in intensive care. Data were analysed for 57 patients; 21 patients (37%) experienced severe reperfusion lung injury. The first extravascular lung water index measurement after cardiopulmonary bypass failed to predict severe reperfusion lung injury, area under the receiver operating characteristic curve 0.59 (95%CI 0.44–0.74). On intensive care, extravascular lung water index correlated most strongly at 36 h, area under the receiver operating characteristic curve 0.90 (95%CI 0.80–1.00). Peri‐operative extravascular lung water index is not a useful measure to predict severe reperfusion lung injury after pulmonary endarterectomy, however, it does allow monitoring and measurement during the postoperative period. This study implies that extravascular lung water index can be used to directly assess pulmonary fluid overload and that monitoring patients by measuring extravascular lung water index during their intensive care stay is useful and correlates with their clinical course. This may allow directed, pre‐empted therapy to attenuate the effects and improve patient outcomes and should prompt further studies. John Wiley and Sons Inc. 2019-07-04 2019-10 /pmc/articles/PMC6772184/ /pubmed/31273760 http://dx.doi.org/10.1111/anae.14744 Text en © 2019 The Authors. Anaesthesia published by John Wiley & Sons Ltd on behalf of Association of Anaesthetists This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made. |
spellingShingle | Original Articles Butchart, A. G. Zochios, V. Villar, S. S. Jones, N. L. Curry, S. Agrawal, B. Jenkins, D. P. Klein, A. A. Measurement of extravascular lung water to diagnose severe reperfusion lung injury following pulmonary endarterectomy: a prospective cohort clinical validation study |
title | Measurement of extravascular lung water to diagnose severe reperfusion lung injury following pulmonary endarterectomy: a prospective cohort clinical validation study
|
title_full | Measurement of extravascular lung water to diagnose severe reperfusion lung injury following pulmonary endarterectomy: a prospective cohort clinical validation study
|
title_fullStr | Measurement of extravascular lung water to diagnose severe reperfusion lung injury following pulmonary endarterectomy: a prospective cohort clinical validation study
|
title_full_unstemmed | Measurement of extravascular lung water to diagnose severe reperfusion lung injury following pulmonary endarterectomy: a prospective cohort clinical validation study
|
title_short | Measurement of extravascular lung water to diagnose severe reperfusion lung injury following pulmonary endarterectomy: a prospective cohort clinical validation study
|
title_sort | measurement of extravascular lung water to diagnose severe reperfusion lung injury following pulmonary endarterectomy: a prospective cohort clinical validation study |
topic | Original Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6772184/ https://www.ncbi.nlm.nih.gov/pubmed/31273760 http://dx.doi.org/10.1111/anae.14744 |
work_keys_str_mv | AT butchartag measurementofextravascularlungwatertodiagnoseseverereperfusionlunginjuryfollowingpulmonaryendarterectomyaprospectivecohortclinicalvalidationstudy AT zochiosv measurementofextravascularlungwatertodiagnoseseverereperfusionlunginjuryfollowingpulmonaryendarterectomyaprospectivecohortclinicalvalidationstudy AT villarss measurementofextravascularlungwatertodiagnoseseverereperfusionlunginjuryfollowingpulmonaryendarterectomyaprospectivecohortclinicalvalidationstudy AT jonesnl measurementofextravascularlungwatertodiagnoseseverereperfusionlunginjuryfollowingpulmonaryendarterectomyaprospectivecohortclinicalvalidationstudy AT currys measurementofextravascularlungwatertodiagnoseseverereperfusionlunginjuryfollowingpulmonaryendarterectomyaprospectivecohortclinicalvalidationstudy AT agrawalb measurementofextravascularlungwatertodiagnoseseverereperfusionlunginjuryfollowingpulmonaryendarterectomyaprospectivecohortclinicalvalidationstudy AT jenkinsdp measurementofextravascularlungwatertodiagnoseseverereperfusionlunginjuryfollowingpulmonaryendarterectomyaprospectivecohortclinicalvalidationstudy AT kleinaa measurementofextravascularlungwatertodiagnoseseverereperfusionlunginjuryfollowingpulmonaryendarterectomyaprospectivecohortclinicalvalidationstudy |