Cargando…

Influence of length, diameter and position of the implant in its fracture incidence: A Systematic Review

Background. Implant fractures can cause difficult problems for patients and dentists. This systematic review aimed to determine the influence of some implant parameters on the occurrence of their fracture and to determine the incidence of fractures reported in recent years. Methods. A search was con...

Descripción completa

Detalles Bibliográficos
Autores principales: Goiato, Marcelo Coelho, Andreotti, Agda Marobo, dos Santos, Daniela Micheline, Nobrega, Adhara Smith, de Caxias, Fernanda Pereira, Bannwart, Lisiane Cristina
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Tabriz University of Medical Sciences 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6773918/
https://www.ncbi.nlm.nih.gov/pubmed/31592306
http://dx.doi.org/10.15171/joddd.2019.017
_version_ 1783455985712496640
author Goiato, Marcelo Coelho
Andreotti, Agda Marobo
dos Santos, Daniela Micheline
Nobrega, Adhara Smith
de Caxias, Fernanda Pereira
Bannwart, Lisiane Cristina
author_facet Goiato, Marcelo Coelho
Andreotti, Agda Marobo
dos Santos, Daniela Micheline
Nobrega, Adhara Smith
de Caxias, Fernanda Pereira
Bannwart, Lisiane Cristina
author_sort Goiato, Marcelo Coelho
collection PubMed
description Background. Implant fractures can cause difficult problems for patients and dentists. This systematic review aimed to determine the influence of some implant parameters on the occurrence of their fracture and to determine the incidence of fractures reported in recent years. Methods. A search was conducted in Pubmed database, from which 12 studies published in the last 12 years were selected. Results. This review reported a 2% incidence of implant fracture. Most implants had been in function between 3 and 4 years until fracture. The studies did not provide necessary information to establish a relationship between the different parameters of implants and the incidence of fractures. Conclusion. Thus, the indication of type, diameter and length of an implant and the bone quality in the region receiving it should be studied and accurately examined for each individual case in order to avoid future failures.
format Online
Article
Text
id pubmed-6773918
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Tabriz University of Medical Sciences
record_format MEDLINE/PubMed
spelling pubmed-67739182019-10-07 Influence of length, diameter and position of the implant in its fracture incidence: A Systematic Review Goiato, Marcelo Coelho Andreotti, Agda Marobo dos Santos, Daniela Micheline Nobrega, Adhara Smith de Caxias, Fernanda Pereira Bannwart, Lisiane Cristina J Dent Res Dent Clin Dent Prospects Original Article Background. Implant fractures can cause difficult problems for patients and dentists. This systematic review aimed to determine the influence of some implant parameters on the occurrence of their fracture and to determine the incidence of fractures reported in recent years. Methods. A search was conducted in Pubmed database, from which 12 studies published in the last 12 years were selected. Results. This review reported a 2% incidence of implant fracture. Most implants had been in function between 3 and 4 years until fracture. The studies did not provide necessary information to establish a relationship between the different parameters of implants and the incidence of fractures. Conclusion. Thus, the indication of type, diameter and length of an implant and the bone quality in the region receiving it should be studied and accurately examined for each individual case in order to avoid future failures. Tabriz University of Medical Sciences 2019 2019-08-14 /pmc/articles/PMC6773918/ /pubmed/31592306 http://dx.doi.org/10.15171/joddd.2019.017 Text en © 2019 Coelho Goiato et al. http://creativecommons.org/licenses/by/4.0/ This is an Open Access article published and distributed by Tabriz University of Medical Sciences under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Goiato, Marcelo Coelho
Andreotti, Agda Marobo
dos Santos, Daniela Micheline
Nobrega, Adhara Smith
de Caxias, Fernanda Pereira
Bannwart, Lisiane Cristina
Influence of length, diameter and position of the implant in its fracture incidence: A Systematic Review
title Influence of length, diameter and position of the implant in its fracture incidence: A Systematic Review
title_full Influence of length, diameter and position of the implant in its fracture incidence: A Systematic Review
title_fullStr Influence of length, diameter and position of the implant in its fracture incidence: A Systematic Review
title_full_unstemmed Influence of length, diameter and position of the implant in its fracture incidence: A Systematic Review
title_short Influence of length, diameter and position of the implant in its fracture incidence: A Systematic Review
title_sort influence of length, diameter and position of the implant in its fracture incidence: a systematic review
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6773918/
https://www.ncbi.nlm.nih.gov/pubmed/31592306
http://dx.doi.org/10.15171/joddd.2019.017
work_keys_str_mv AT goiatomarcelocoelho influenceoflengthdiameterandpositionoftheimplantinitsfractureincidenceasystematicreview
AT andreottiagdamarobo influenceoflengthdiameterandpositionoftheimplantinitsfractureincidenceasystematicreview
AT dossantosdanielamicheline influenceoflengthdiameterandpositionoftheimplantinitsfractureincidenceasystematicreview
AT nobregaadharasmith influenceoflengthdiameterandpositionoftheimplantinitsfractureincidenceasystematicreview
AT decaxiasfernandapereira influenceoflengthdiameterandpositionoftheimplantinitsfractureincidenceasystematicreview
AT bannwartlisianecristina influenceoflengthdiameterandpositionoftheimplantinitsfractureincidenceasystematicreview