Cargando…

A Multi-Channel Asynchronous Neurostimulator With Artifact Suppression for Neural Code-Based Stimulations

A novel neurostimulator for generating neural code-based, precise, asynchronous electrical stimulation pulses is designed, fabricated, and characterized. Through multiplexing, this system can deliver constant current biphasic pulses, with arbitrary temporal patterns, and pulse parameters to 32 elect...

Descripción completa

Detalles Bibliográficos
Autores principales: Elyahoodayan, Sahar, Jiang, Wenxuan, Xu, Huijing, Song, Dong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6776638/
https://www.ncbi.nlm.nih.gov/pubmed/31611764
http://dx.doi.org/10.3389/fnins.2019.01011
_version_ 1783456485248860160
author Elyahoodayan, Sahar
Jiang, Wenxuan
Xu, Huijing
Song, Dong
author_facet Elyahoodayan, Sahar
Jiang, Wenxuan
Xu, Huijing
Song, Dong
author_sort Elyahoodayan, Sahar
collection PubMed
description A novel neurostimulator for generating neural code-based, precise, asynchronous electrical stimulation pulses is designed, fabricated, and characterized. Through multiplexing, this system can deliver constant current biphasic pulses, with arbitrary temporal patterns, and pulse parameters to 32 electrodes using one pulse generator. The design also features a stimulus artifact suppression (SAS) technique that can be integrated with commercial amplifiers. Using an array of CMOS switches, electrodes are disconnected from recording amplifiers during stimulation, while the input of the recording system is shorted to ground through another CMOS switch to suppress ringing in the recording system. The timing of the switches used to block and suppress the stimulus artifact are crucial and are determined by the electrochemical properties of the electrode. This system allows stimulation and recording from the same electrodes to monitor local field potentials with short latencies from the region of stimulation for achieving feedback control of neural stimulation. In this way, timing between each pulse is controlled by inputs from an external source and stimulus magnitude is controlled by feed-back from neural response from the stimulated tissue. The system was implemented with low-power and compact packaged microchips to constitute an effective, cost-efficient, and miniaturized neurostimulator. The device has been first evaluated in phantom preparations and then tested in hippocampi of behaving rats. Benchtop results demonstrate the capability of the stimulator to generate arbitrary spatio-temporal pattern of stimulation pulses dictated by random number generators (RNGs) to control magnitude and timing between each individual biphasic pulse. In vivo results show that evoked potentials elicited by the neurostimulator can be recorded ∼2 ms after the termination of stimulus pulses from the same electrodes where stimulation pulses are delivered, whereas commercial amplifiers without such an artifact suppression typically result in tens to hundreds of milliseconds recovery period. This neurostimulator design is desirable in a variety of neural interface applications, particularly hippocampal memory prosthesis aiming to restore cognitive functions by reinstating neural code transmissions in the brain.
format Online
Article
Text
id pubmed-6776638
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-67766382019-10-14 A Multi-Channel Asynchronous Neurostimulator With Artifact Suppression for Neural Code-Based Stimulations Elyahoodayan, Sahar Jiang, Wenxuan Xu, Huijing Song, Dong Front Neurosci Neuroscience A novel neurostimulator for generating neural code-based, precise, asynchronous electrical stimulation pulses is designed, fabricated, and characterized. Through multiplexing, this system can deliver constant current biphasic pulses, with arbitrary temporal patterns, and pulse parameters to 32 electrodes using one pulse generator. The design also features a stimulus artifact suppression (SAS) technique that can be integrated with commercial amplifiers. Using an array of CMOS switches, electrodes are disconnected from recording amplifiers during stimulation, while the input of the recording system is shorted to ground through another CMOS switch to suppress ringing in the recording system. The timing of the switches used to block and suppress the stimulus artifact are crucial and are determined by the electrochemical properties of the electrode. This system allows stimulation and recording from the same electrodes to monitor local field potentials with short latencies from the region of stimulation for achieving feedback control of neural stimulation. In this way, timing between each pulse is controlled by inputs from an external source and stimulus magnitude is controlled by feed-back from neural response from the stimulated tissue. The system was implemented with low-power and compact packaged microchips to constitute an effective, cost-efficient, and miniaturized neurostimulator. The device has been first evaluated in phantom preparations and then tested in hippocampi of behaving rats. Benchtop results demonstrate the capability of the stimulator to generate arbitrary spatio-temporal pattern of stimulation pulses dictated by random number generators (RNGs) to control magnitude and timing between each individual biphasic pulse. In vivo results show that evoked potentials elicited by the neurostimulator can be recorded ∼2 ms after the termination of stimulus pulses from the same electrodes where stimulation pulses are delivered, whereas commercial amplifiers without such an artifact suppression typically result in tens to hundreds of milliseconds recovery period. This neurostimulator design is desirable in a variety of neural interface applications, particularly hippocampal memory prosthesis aiming to restore cognitive functions by reinstating neural code transmissions in the brain. Frontiers Media S.A. 2019-09-27 /pmc/articles/PMC6776638/ /pubmed/31611764 http://dx.doi.org/10.3389/fnins.2019.01011 Text en Copyright © 2019 Elyahoodayan, Jiang, Xu and Song. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Neuroscience
Elyahoodayan, Sahar
Jiang, Wenxuan
Xu, Huijing
Song, Dong
A Multi-Channel Asynchronous Neurostimulator With Artifact Suppression for Neural Code-Based Stimulations
title A Multi-Channel Asynchronous Neurostimulator With Artifact Suppression for Neural Code-Based Stimulations
title_full A Multi-Channel Asynchronous Neurostimulator With Artifact Suppression for Neural Code-Based Stimulations
title_fullStr A Multi-Channel Asynchronous Neurostimulator With Artifact Suppression for Neural Code-Based Stimulations
title_full_unstemmed A Multi-Channel Asynchronous Neurostimulator With Artifact Suppression for Neural Code-Based Stimulations
title_short A Multi-Channel Asynchronous Neurostimulator With Artifact Suppression for Neural Code-Based Stimulations
title_sort multi-channel asynchronous neurostimulator with artifact suppression for neural code-based stimulations
topic Neuroscience
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6776638/
https://www.ncbi.nlm.nih.gov/pubmed/31611764
http://dx.doi.org/10.3389/fnins.2019.01011
work_keys_str_mv AT elyahoodayansahar amultichannelasynchronousneurostimulatorwithartifactsuppressionforneuralcodebasedstimulations
AT jiangwenxuan amultichannelasynchronousneurostimulatorwithartifactsuppressionforneuralcodebasedstimulations
AT xuhuijing amultichannelasynchronousneurostimulatorwithartifactsuppressionforneuralcodebasedstimulations
AT songdong amultichannelasynchronousneurostimulatorwithartifactsuppressionforneuralcodebasedstimulations
AT elyahoodayansahar multichannelasynchronousneurostimulatorwithartifactsuppressionforneuralcodebasedstimulations
AT jiangwenxuan multichannelasynchronousneurostimulatorwithartifactsuppressionforneuralcodebasedstimulations
AT xuhuijing multichannelasynchronousneurostimulatorwithartifactsuppressionforneuralcodebasedstimulations
AT songdong multichannelasynchronousneurostimulatorwithartifactsuppressionforneuralcodebasedstimulations