Cargando…

Clinical outcomes associated with the use of the NexSite hemodialysis catheter with new exit barrier technology: Results from a prospective, observational multi-center registry study

PURPOSE: Decreasing the risk of catheter related bloodstream infections (CRBSIs) remains a key focus for improving outcomes and reducing cost of care for hemodialysis (HD) patients. Recent studies demonstrate CRBSI rates can be improved by managing bacterial colonization at the catheter exit site. H...

Descripción completa

Detalles Bibliográficos
Autores principales: Hoggard, Jeffrey G., Blair, Richard D., Montero, Manuel, Moustafa, Moustafa A., Newman, Joseph, Pergola, Pablo E., Saucier, Nathan, Wheeler, Clarence J., Mermel, Leonard A., Ross, John R., Beserab, Anatole D.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6779244/
https://www.ncbi.nlm.nih.gov/pubmed/31589644
http://dx.doi.org/10.1371/journal.pone.0223285
_version_ 1783456900868734976
author Hoggard, Jeffrey G.
Blair, Richard D.
Montero, Manuel
Moustafa, Moustafa A.
Newman, Joseph
Pergola, Pablo E.
Saucier, Nathan
Wheeler, Clarence J.
Mermel, Leonard A.
Ross, John R.
Beserab, Anatole D.
author_facet Hoggard, Jeffrey G.
Blair, Richard D.
Montero, Manuel
Moustafa, Moustafa A.
Newman, Joseph
Pergola, Pablo E.
Saucier, Nathan
Wheeler, Clarence J.
Mermel, Leonard A.
Ross, John R.
Beserab, Anatole D.
author_sort Hoggard, Jeffrey G.
collection PubMed
description PURPOSE: Decreasing the risk of catheter related bloodstream infections (CRBSIs) remains a key focus for improving outcomes and reducing cost of care for hemodialysis (HD) patients. Recent studies demonstrate CRBSI rates can be improved by managing bacterial colonization at the catheter exit site. Herein we present the results of a study documenting the clinical performance of the NexSite HD catheter, a new tunneled central venous catheter which incorporates Exit Site Management (ESM) technology. METHODS: We conducted an observational study using a prospective, multi-center registry of HD patients implanted with the NexSite HD catheter. The primary endpoint for the study was CRBSI rate for a period up to 180-days following catheter placement. Secondary endpoints included device placement success rate, exit site healing, development of an exit site or tunnel infection, and early or late non-infectious catheter-related complications. All reasons for early non-elective catheter removal were recorded. RESULTS: A total of 115 HD patients at 6 sites were included in the final analysis. Cumulative catheter use was 10,924 days with a mean duration of 95 days. Seven patients experienced CRBSIs during the study period resulting in a CRBSI rate of 0.64 per 1,000 catheter-days. Seventy-four patients (64.3%) had either elective catheter removal (n = 56) or utilized the catheter for the entire 180-day observation period (n = 18). Thirty-five patients (30%) underwent non-elective device removal either due to CRBSI (n = 5), low flow (n = 16), exit site issues (n = 7), or for other causes (n = 7). Six patients died during the observation period with 1 death due to CRBSI-associated complications and the remaining 5 deaths attributed to non-device related causes. CONCLUSION: Our findings demonstrate that the NexSite HD catheter equipped with ESM technology can achieve a CRBSI rate in compliance with the NKF KDOQI (National Kidney Foundation Kidney Disease Outcome Quality Initiatives) Clinical Performance Guidelines stated goal of less than 1.0/1,000 catheter-days when used in hemodialysis patients using current standard of care nursing protocols.
format Online
Article
Text
id pubmed-6779244
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-67792442019-10-19 Clinical outcomes associated with the use of the NexSite hemodialysis catheter with new exit barrier technology: Results from a prospective, observational multi-center registry study Hoggard, Jeffrey G. Blair, Richard D. Montero, Manuel Moustafa, Moustafa A. Newman, Joseph Pergola, Pablo E. Saucier, Nathan Wheeler, Clarence J. Mermel, Leonard A. Ross, John R. Beserab, Anatole D. PLoS One Research Article PURPOSE: Decreasing the risk of catheter related bloodstream infections (CRBSIs) remains a key focus for improving outcomes and reducing cost of care for hemodialysis (HD) patients. Recent studies demonstrate CRBSI rates can be improved by managing bacterial colonization at the catheter exit site. Herein we present the results of a study documenting the clinical performance of the NexSite HD catheter, a new tunneled central venous catheter which incorporates Exit Site Management (ESM) technology. METHODS: We conducted an observational study using a prospective, multi-center registry of HD patients implanted with the NexSite HD catheter. The primary endpoint for the study was CRBSI rate for a period up to 180-days following catheter placement. Secondary endpoints included device placement success rate, exit site healing, development of an exit site or tunnel infection, and early or late non-infectious catheter-related complications. All reasons for early non-elective catheter removal were recorded. RESULTS: A total of 115 HD patients at 6 sites were included in the final analysis. Cumulative catheter use was 10,924 days with a mean duration of 95 days. Seven patients experienced CRBSIs during the study period resulting in a CRBSI rate of 0.64 per 1,000 catheter-days. Seventy-four patients (64.3%) had either elective catheter removal (n = 56) or utilized the catheter for the entire 180-day observation period (n = 18). Thirty-five patients (30%) underwent non-elective device removal either due to CRBSI (n = 5), low flow (n = 16), exit site issues (n = 7), or for other causes (n = 7). Six patients died during the observation period with 1 death due to CRBSI-associated complications and the remaining 5 deaths attributed to non-device related causes. CONCLUSION: Our findings demonstrate that the NexSite HD catheter equipped with ESM technology can achieve a CRBSI rate in compliance with the NKF KDOQI (National Kidney Foundation Kidney Disease Outcome Quality Initiatives) Clinical Performance Guidelines stated goal of less than 1.0/1,000 catheter-days when used in hemodialysis patients using current standard of care nursing protocols. Public Library of Science 2019-10-07 /pmc/articles/PMC6779244/ /pubmed/31589644 http://dx.doi.org/10.1371/journal.pone.0223285 Text en © 2019 Hoggard et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Hoggard, Jeffrey G.
Blair, Richard D.
Montero, Manuel
Moustafa, Moustafa A.
Newman, Joseph
Pergola, Pablo E.
Saucier, Nathan
Wheeler, Clarence J.
Mermel, Leonard A.
Ross, John R.
Beserab, Anatole D.
Clinical outcomes associated with the use of the NexSite hemodialysis catheter with new exit barrier technology: Results from a prospective, observational multi-center registry study
title Clinical outcomes associated with the use of the NexSite hemodialysis catheter with new exit barrier technology: Results from a prospective, observational multi-center registry study
title_full Clinical outcomes associated with the use of the NexSite hemodialysis catheter with new exit barrier technology: Results from a prospective, observational multi-center registry study
title_fullStr Clinical outcomes associated with the use of the NexSite hemodialysis catheter with new exit barrier technology: Results from a prospective, observational multi-center registry study
title_full_unstemmed Clinical outcomes associated with the use of the NexSite hemodialysis catheter with new exit barrier technology: Results from a prospective, observational multi-center registry study
title_short Clinical outcomes associated with the use of the NexSite hemodialysis catheter with new exit barrier technology: Results from a prospective, observational multi-center registry study
title_sort clinical outcomes associated with the use of the nexsite hemodialysis catheter with new exit barrier technology: results from a prospective, observational multi-center registry study
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6779244/
https://www.ncbi.nlm.nih.gov/pubmed/31589644
http://dx.doi.org/10.1371/journal.pone.0223285
work_keys_str_mv AT hoggardjeffreyg clinicaloutcomesassociatedwiththeuseofthenexsitehemodialysiscatheterwithnewexitbarriertechnologyresultsfromaprospectiveobservationalmulticenterregistrystudy
AT blairrichardd clinicaloutcomesassociatedwiththeuseofthenexsitehemodialysiscatheterwithnewexitbarriertechnologyresultsfromaprospectiveobservationalmulticenterregistrystudy
AT monteromanuel clinicaloutcomesassociatedwiththeuseofthenexsitehemodialysiscatheterwithnewexitbarriertechnologyresultsfromaprospectiveobservationalmulticenterregistrystudy
AT moustafamoustafaa clinicaloutcomesassociatedwiththeuseofthenexsitehemodialysiscatheterwithnewexitbarriertechnologyresultsfromaprospectiveobservationalmulticenterregistrystudy
AT newmanjoseph clinicaloutcomesassociatedwiththeuseofthenexsitehemodialysiscatheterwithnewexitbarriertechnologyresultsfromaprospectiveobservationalmulticenterregistrystudy
AT pergolapabloe clinicaloutcomesassociatedwiththeuseofthenexsitehemodialysiscatheterwithnewexitbarriertechnologyresultsfromaprospectiveobservationalmulticenterregistrystudy
AT sauciernathan clinicaloutcomesassociatedwiththeuseofthenexsitehemodialysiscatheterwithnewexitbarriertechnologyresultsfromaprospectiveobservationalmulticenterregistrystudy
AT wheelerclarencej clinicaloutcomesassociatedwiththeuseofthenexsitehemodialysiscatheterwithnewexitbarriertechnologyresultsfromaprospectiveobservationalmulticenterregistrystudy
AT mermelleonarda clinicaloutcomesassociatedwiththeuseofthenexsitehemodialysiscatheterwithnewexitbarriertechnologyresultsfromaprospectiveobservationalmulticenterregistrystudy
AT rossjohnr clinicaloutcomesassociatedwiththeuseofthenexsitehemodialysiscatheterwithnewexitbarriertechnologyresultsfromaprospectiveobservationalmulticenterregistrystudy
AT beserabanatoled clinicaloutcomesassociatedwiththeuseofthenexsitehemodialysiscatheterwithnewexitbarriertechnologyresultsfromaprospectiveobservationalmulticenterregistrystudy