Cargando…
Duration of Implantable Cardiac Monitoring and Detection of Atrial Fibrillation in Ischemic Stroke Patients: A Systematic Review and Meta-Analysis
BACKGROUND AND PURPOSE: Current guidelines do not provide firm directions on atrial fibrillation (AF) screening after ischemic stroke (IS). We sought to investigate the association of implantable cardiac monitoring (ICM) duration with the yield of AF detection in IS patients. METHODS: We included st...
Autores principales: | , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Stroke Society
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6780018/ https://www.ncbi.nlm.nih.gov/pubmed/31590474 http://dx.doi.org/10.5853/jos.2019.01067 |
_version_ | 1783457029832048640 |
---|---|
author | Tsivgoulis, Georgios Katsanos, Aristeidis H. Köhrmann, Martin Caso, Valeria Perren, Fabienne Palaiodimou, Lina Deftereos, Spyridon Giannopoulos, Sotirios Ellul, John Krogias, Christos Mavridis, Dimitris Triantafyllou, Sokratis Alexandrov, Anne W. Schellinger, Peter D. Alexandrov, Andrei V. |
author_facet | Tsivgoulis, Georgios Katsanos, Aristeidis H. Köhrmann, Martin Caso, Valeria Perren, Fabienne Palaiodimou, Lina Deftereos, Spyridon Giannopoulos, Sotirios Ellul, John Krogias, Christos Mavridis, Dimitris Triantafyllou, Sokratis Alexandrov, Anne W. Schellinger, Peter D. Alexandrov, Andrei V. |
author_sort | Tsivgoulis, Georgios |
collection | PubMed |
description | BACKGROUND AND PURPOSE: Current guidelines do not provide firm directions on atrial fibrillation (AF) screening after ischemic stroke (IS). We sought to investigate the association of implantable cardiac monitoring (ICM) duration with the yield of AF detection in IS patients. METHODS: We included studies reporting AF detection rates by ICM in IS patients with negative initial AF screening. We excluded studies reporting prolonged cardiac monitoring with devices other than ICM, not providing AF detection rates or monitoring duration, and reporting overlapping data for the same population. The random-effects model was used for all pooled estimates and meta-regression analyses. RESULTS: We included 28 studies (4,531 patients, mean age 65 years). In meta-regression analyses, the proportion of AF detection by ICM was independently associated with monitoring duration (coefficient=0.015; 95% confidence interval [CI], 0.005 to 0.024) and mean patient age (coefficient=0.009; 95% CI, 0.003 to 0.015). No associations were detected with other patient characteristics, including IS subtype (cryptogenic vs. embolic stroke of undetermined source) or time from IS onset to CM implantation. In subgroup analyses, significant differences (P<0.001) in the AF detection rates were found for ICM duration (<6 months: 5% [95% CI, 3% to 6%]; ≥6 and ≤12 months: 21% [95% CI, 16% to 25%]; >12 and ≤24 months: 26% [95% CI, 22% to 31%]; >24 months: 34% [95% CI, 29% to 39%]). CONCLUSIONS: Extended duration of ICM monitoring and increased patient age are factors that substantially increase AF detection in IS patients with initial negative AF screening. |
format | Online Article Text |
id | pubmed-6780018 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Korean Stroke Society |
record_format | MEDLINE/PubMed |
spelling | pubmed-67800182019-10-17 Duration of Implantable Cardiac Monitoring and Detection of Atrial Fibrillation in Ischemic Stroke Patients: A Systematic Review and Meta-Analysis Tsivgoulis, Georgios Katsanos, Aristeidis H. Köhrmann, Martin Caso, Valeria Perren, Fabienne Palaiodimou, Lina Deftereos, Spyridon Giannopoulos, Sotirios Ellul, John Krogias, Christos Mavridis, Dimitris Triantafyllou, Sokratis Alexandrov, Anne W. Schellinger, Peter D. Alexandrov, Andrei V. J Stroke Original Article BACKGROUND AND PURPOSE: Current guidelines do not provide firm directions on atrial fibrillation (AF) screening after ischemic stroke (IS). We sought to investigate the association of implantable cardiac monitoring (ICM) duration with the yield of AF detection in IS patients. METHODS: We included studies reporting AF detection rates by ICM in IS patients with negative initial AF screening. We excluded studies reporting prolonged cardiac monitoring with devices other than ICM, not providing AF detection rates or monitoring duration, and reporting overlapping data for the same population. The random-effects model was used for all pooled estimates and meta-regression analyses. RESULTS: We included 28 studies (4,531 patients, mean age 65 years). In meta-regression analyses, the proportion of AF detection by ICM was independently associated with monitoring duration (coefficient=0.015; 95% confidence interval [CI], 0.005 to 0.024) and mean patient age (coefficient=0.009; 95% CI, 0.003 to 0.015). No associations were detected with other patient characteristics, including IS subtype (cryptogenic vs. embolic stroke of undetermined source) or time from IS onset to CM implantation. In subgroup analyses, significant differences (P<0.001) in the AF detection rates were found for ICM duration (<6 months: 5% [95% CI, 3% to 6%]; ≥6 and ≤12 months: 21% [95% CI, 16% to 25%]; >12 and ≤24 months: 26% [95% CI, 22% to 31%]; >24 months: 34% [95% CI, 29% to 39%]). CONCLUSIONS: Extended duration of ICM monitoring and increased patient age are factors that substantially increase AF detection in IS patients with initial negative AF screening. Korean Stroke Society 2019-09 2019-09-30 /pmc/articles/PMC6780018/ /pubmed/31590474 http://dx.doi.org/10.5853/jos.2019.01067 Text en Copyright © 2019 Korean Stroke Society This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted noncommercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Tsivgoulis, Georgios Katsanos, Aristeidis H. Köhrmann, Martin Caso, Valeria Perren, Fabienne Palaiodimou, Lina Deftereos, Spyridon Giannopoulos, Sotirios Ellul, John Krogias, Christos Mavridis, Dimitris Triantafyllou, Sokratis Alexandrov, Anne W. Schellinger, Peter D. Alexandrov, Andrei V. Duration of Implantable Cardiac Monitoring and Detection of Atrial Fibrillation in Ischemic Stroke Patients: A Systematic Review and Meta-Analysis |
title | Duration of Implantable Cardiac Monitoring and Detection of Atrial Fibrillation in Ischemic Stroke Patients: A Systematic Review and Meta-Analysis |
title_full | Duration of Implantable Cardiac Monitoring and Detection of Atrial Fibrillation in Ischemic Stroke Patients: A Systematic Review and Meta-Analysis |
title_fullStr | Duration of Implantable Cardiac Monitoring and Detection of Atrial Fibrillation in Ischemic Stroke Patients: A Systematic Review and Meta-Analysis |
title_full_unstemmed | Duration of Implantable Cardiac Monitoring and Detection of Atrial Fibrillation in Ischemic Stroke Patients: A Systematic Review and Meta-Analysis |
title_short | Duration of Implantable Cardiac Monitoring and Detection of Atrial Fibrillation in Ischemic Stroke Patients: A Systematic Review and Meta-Analysis |
title_sort | duration of implantable cardiac monitoring and detection of atrial fibrillation in ischemic stroke patients: a systematic review and meta-analysis |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6780018/ https://www.ncbi.nlm.nih.gov/pubmed/31590474 http://dx.doi.org/10.5853/jos.2019.01067 |
work_keys_str_mv | AT tsivgoulisgeorgios durationofimplantablecardiacmonitoringanddetectionofatrialfibrillationinischemicstrokepatientsasystematicreviewandmetaanalysis AT katsanosaristeidish durationofimplantablecardiacmonitoringanddetectionofatrialfibrillationinischemicstrokepatientsasystematicreviewandmetaanalysis AT kohrmannmartin durationofimplantablecardiacmonitoringanddetectionofatrialfibrillationinischemicstrokepatientsasystematicreviewandmetaanalysis AT casovaleria durationofimplantablecardiacmonitoringanddetectionofatrialfibrillationinischemicstrokepatientsasystematicreviewandmetaanalysis AT perrenfabienne durationofimplantablecardiacmonitoringanddetectionofatrialfibrillationinischemicstrokepatientsasystematicreviewandmetaanalysis AT palaiodimoulina durationofimplantablecardiacmonitoringanddetectionofatrialfibrillationinischemicstrokepatientsasystematicreviewandmetaanalysis AT deftereosspyridon durationofimplantablecardiacmonitoringanddetectionofatrialfibrillationinischemicstrokepatientsasystematicreviewandmetaanalysis AT giannopoulossotirios durationofimplantablecardiacmonitoringanddetectionofatrialfibrillationinischemicstrokepatientsasystematicreviewandmetaanalysis AT elluljohn durationofimplantablecardiacmonitoringanddetectionofatrialfibrillationinischemicstrokepatientsasystematicreviewandmetaanalysis AT krogiaschristos durationofimplantablecardiacmonitoringanddetectionofatrialfibrillationinischemicstrokepatientsasystematicreviewandmetaanalysis AT mavridisdimitris durationofimplantablecardiacmonitoringanddetectionofatrialfibrillationinischemicstrokepatientsasystematicreviewandmetaanalysis AT triantafyllousokratis durationofimplantablecardiacmonitoringanddetectionofatrialfibrillationinischemicstrokepatientsasystematicreviewandmetaanalysis AT alexandrovannew durationofimplantablecardiacmonitoringanddetectionofatrialfibrillationinischemicstrokepatientsasystematicreviewandmetaanalysis AT schellingerpeterd durationofimplantablecardiacmonitoringanddetectionofatrialfibrillationinischemicstrokepatientsasystematicreviewandmetaanalysis AT alexandrovandreiv durationofimplantablecardiacmonitoringanddetectionofatrialfibrillationinischemicstrokepatientsasystematicreviewandmetaanalysis |