An Optoelectronic System for Measuring the Range of Motion in Healthy Volunteers: A Cross-Sectional Study

Background and Objectives: Within the clinical evaluation of multiple pathologies of the lower limb, the measurement of range of motion (ROM) of its joints is fundamental. To this end, there are various tools, from the goniometer as a reference to more recent devices such as inclinometry-based appli...

Descripción completa

Detalles Bibliográficos
Autores principales: Medina-Mirapeix, Francesc, Martín-San Agustín, Rodrigo, Cánovas-Ambit, Germán, García-Vidal, José A., Gacto-Sánchez, Mariano, Escolar-Reina, Pilar
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6780862/
https://www.ncbi.nlm.nih.gov/pubmed/31443368
http://dx.doi.org/10.3390/medicina55090516
_version_ 1783457240281251840
author Medina-Mirapeix, Francesc
Martín-San Agustín, Rodrigo
Cánovas-Ambit, Germán
García-Vidal, José A.
Gacto-Sánchez, Mariano
Escolar-Reina, Pilar
author_facet Medina-Mirapeix, Francesc
Martín-San Agustín, Rodrigo
Cánovas-Ambit, Germán
García-Vidal, José A.
Gacto-Sánchez, Mariano
Escolar-Reina, Pilar
author_sort Medina-Mirapeix, Francesc
collection PubMed
description Background and Objectives: Within the clinical evaluation of multiple pathologies of the lower limb, the measurement of range of motion (ROM) of its joints is fundamental. To this end, there are various tools, from the goniometer as a reference to more recent devices such as inclinometry-based applications, photo capture applications, or motion capture systems. This study aimed to assess the validity, intra-rater, and inter-rater reliability of the VeloFlex system (VS), which is a new camera-based tool designed for tracking joint trajectories and measuring joint ROM. Materials and Methods: Thirty-five healthy volunteers (16 females; aged 18–61 years) participated in this study. All participants were assessed on two separate occasions, one week apart. During the first assessment session, measurements were obtained using a goniometer and the VS, whereas, in the second session, only the VS was used. In each assessment session, nine active movements were examined. For each movement, three trials were tested, and the mean of these three measures was used for analysis. To evaluate the concurrent validity and agreement, the Pearson correlation coefficient (r) and Bland-Altmann plots were used. Intra-rater and inter-rater reliability were evaluated using intra-class correlation (ICC), standard error of measurement (SEM), and minimal detectable change (MDC). Results: Both devices showed excellent correlations for all movements (r ranged from 0.992 to 0.999). The intra-rater reliability of the VS was excellent (ICC ranged from 0.93 to 0.99), SEMs ranged from 0.53% to 2.61% and the MDC ranged from 0.68° to 3.26°. The inter-rater reliability of the VS was also excellent (ICC ranged from 0.88 to 0.98), SEMs ranged from 0.81% to 4.76% and the MDC ranged from 2.27° to 4.42°. Conclusions: The VS is a valid and reliable tool for the measurement of ROM of lower limb joints in healthy subjects.
format Online
Article
Text
id pubmed-6780862
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-67808622019-10-30 An Optoelectronic System for Measuring the Range of Motion in Healthy Volunteers: A Cross-Sectional Study Medina-Mirapeix, Francesc Martín-San Agustín, Rodrigo Cánovas-Ambit, Germán García-Vidal, José A. Gacto-Sánchez, Mariano Escolar-Reina, Pilar Medicina (Kaunas) Article Background and Objectives: Within the clinical evaluation of multiple pathologies of the lower limb, the measurement of range of motion (ROM) of its joints is fundamental. To this end, there are various tools, from the goniometer as a reference to more recent devices such as inclinometry-based applications, photo capture applications, or motion capture systems. This study aimed to assess the validity, intra-rater, and inter-rater reliability of the VeloFlex system (VS), which is a new camera-based tool designed for tracking joint trajectories and measuring joint ROM. Materials and Methods: Thirty-five healthy volunteers (16 females; aged 18–61 years) participated in this study. All participants were assessed on two separate occasions, one week apart. During the first assessment session, measurements were obtained using a goniometer and the VS, whereas, in the second session, only the VS was used. In each assessment session, nine active movements were examined. For each movement, three trials were tested, and the mean of these three measures was used for analysis. To evaluate the concurrent validity and agreement, the Pearson correlation coefficient (r) and Bland-Altmann plots were used. Intra-rater and inter-rater reliability were evaluated using intra-class correlation (ICC), standard error of measurement (SEM), and minimal detectable change (MDC). Results: Both devices showed excellent correlations for all movements (r ranged from 0.992 to 0.999). The intra-rater reliability of the VS was excellent (ICC ranged from 0.93 to 0.99), SEMs ranged from 0.53% to 2.61% and the MDC ranged from 0.68° to 3.26°. The inter-rater reliability of the VS was also excellent (ICC ranged from 0.88 to 0.98), SEMs ranged from 0.81% to 4.76% and the MDC ranged from 2.27° to 4.42°. Conclusions: The VS is a valid and reliable tool for the measurement of ROM of lower limb joints in healthy subjects. MDPI 2019-08-22 /pmc/articles/PMC6780862/ /pubmed/31443368 http://dx.doi.org/10.3390/medicina55090516 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Medina-Mirapeix, Francesc
Martín-San Agustín, Rodrigo
Cánovas-Ambit, Germán
García-Vidal, José A.
Gacto-Sánchez, Mariano
Escolar-Reina, Pilar
An Optoelectronic System for Measuring the Range of Motion in Healthy Volunteers: A Cross-Sectional Study
title An Optoelectronic System for Measuring the Range of Motion in Healthy Volunteers: A Cross-Sectional Study
title_full An Optoelectronic System for Measuring the Range of Motion in Healthy Volunteers: A Cross-Sectional Study
title_fullStr An Optoelectronic System for Measuring the Range of Motion in Healthy Volunteers: A Cross-Sectional Study
title_full_unstemmed An Optoelectronic System for Measuring the Range of Motion in Healthy Volunteers: A Cross-Sectional Study
title_short An Optoelectronic System for Measuring the Range of Motion in Healthy Volunteers: A Cross-Sectional Study
title_sort optoelectronic system for measuring the range of motion in healthy volunteers: a cross-sectional study
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6780862/
https://www.ncbi.nlm.nih.gov/pubmed/31443368
http://dx.doi.org/10.3390/medicina55090516
work_keys_str_mv AT medinamirapeixfrancesc anoptoelectronicsystemformeasuringtherangeofmotioninhealthyvolunteersacrosssectionalstudy
AT martinsanagustinrodrigo anoptoelectronicsystemformeasuringtherangeofmotioninhealthyvolunteersacrosssectionalstudy
AT canovasambitgerman anoptoelectronicsystemformeasuringtherangeofmotioninhealthyvolunteersacrosssectionalstudy
AT garciavidaljosea anoptoelectronicsystemformeasuringtherangeofmotioninhealthyvolunteersacrosssectionalstudy
AT gactosanchezmariano anoptoelectronicsystemformeasuringtherangeofmotioninhealthyvolunteersacrosssectionalstudy
AT escolarreinapilar anoptoelectronicsystemformeasuringtherangeofmotioninhealthyvolunteersacrosssectionalstudy
AT medinamirapeixfrancesc optoelectronicsystemformeasuringtherangeofmotioninhealthyvolunteersacrosssectionalstudy
AT martinsanagustinrodrigo optoelectronicsystemformeasuringtherangeofmotioninhealthyvolunteersacrosssectionalstudy
AT canovasambitgerman optoelectronicsystemformeasuringtherangeofmotioninhealthyvolunteersacrosssectionalstudy
AT garciavidaljosea optoelectronicsystemformeasuringtherangeofmotioninhealthyvolunteersacrosssectionalstudy
AT gactosanchezmariano optoelectronicsystemformeasuringtherangeofmotioninhealthyvolunteersacrosssectionalstudy
AT escolarreinapilar optoelectronicsystemformeasuringtherangeofmotioninhealthyvolunteersacrosssectionalstudy