Cargando…

Development of a Label-Free Electrochemical Aptasensor for the Detection of Tau381 and its Preliminary Application in AD and Non-AD Patients’ Sera

The electrochemical aptamer sensor has been designed for detecting tau381, a critical biomarker of Alzheimer′s disease in human serum. The aptasensor is obtained by immobilizing the aptamer on a carboxyl graphene/thionin/gold nanoparticle modified glassy-carbon electrode. As a probe and bridge molec...

Descripción completa

Detalles Bibliográficos
Autores principales: Tao, Dan, Shui, Bingqing, Gu, Yingying, Cheng, Jing, Zhang, Weiying, Jaffrezic-Renault, Nicole, Song, Shizhen, Guo, Zhenzhong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6784373/
https://www.ncbi.nlm.nih.gov/pubmed/31262001
http://dx.doi.org/10.3390/bios9030084
_version_ 1783457748604682240
author Tao, Dan
Shui, Bingqing
Gu, Yingying
Cheng, Jing
Zhang, Weiying
Jaffrezic-Renault, Nicole
Song, Shizhen
Guo, Zhenzhong
author_facet Tao, Dan
Shui, Bingqing
Gu, Yingying
Cheng, Jing
Zhang, Weiying
Jaffrezic-Renault, Nicole
Song, Shizhen
Guo, Zhenzhong
author_sort Tao, Dan
collection PubMed
description The electrochemical aptamer sensor has been designed for detecting tau381, a critical biomarker of Alzheimer′s disease in human serum. The aptasensor is obtained by immobilizing the aptamer on a carboxyl graphene/thionin/gold nanoparticle modified glassy-carbon electrode. As a probe and bridge molecule, thionin connected carboxyl graphene and gold nanoparticles, and gave the electrical signal. Under optimal conditions, the increment of differential pulse voltammetry signal increased linearly with the logarithm of tau381 concentration in the range from 1.0 pM to 100 pM, and limit of detection was 0.70 pM. The aptasensor reliability was evaluated by determining its selectivity, reproducibility, stability, detection limit, and recovery. Performance analysis of the tau381 aptasensor in 10 patients’ serum samples showed that the aptasensor could screen patients with and without Alzheimer′s disease. The proposed aptasensor has potential for use in clinically diagnosing Alzheimer′s disease in the early stage.
format Online
Article
Text
id pubmed-6784373
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-67843732019-10-16 Development of a Label-Free Electrochemical Aptasensor for the Detection of Tau381 and its Preliminary Application in AD and Non-AD Patients’ Sera Tao, Dan Shui, Bingqing Gu, Yingying Cheng, Jing Zhang, Weiying Jaffrezic-Renault, Nicole Song, Shizhen Guo, Zhenzhong Biosensors (Basel) Article The electrochemical aptamer sensor has been designed for detecting tau381, a critical biomarker of Alzheimer′s disease in human serum. The aptasensor is obtained by immobilizing the aptamer on a carboxyl graphene/thionin/gold nanoparticle modified glassy-carbon electrode. As a probe and bridge molecule, thionin connected carboxyl graphene and gold nanoparticles, and gave the electrical signal. Under optimal conditions, the increment of differential pulse voltammetry signal increased linearly with the logarithm of tau381 concentration in the range from 1.0 pM to 100 pM, and limit of detection was 0.70 pM. The aptasensor reliability was evaluated by determining its selectivity, reproducibility, stability, detection limit, and recovery. Performance analysis of the tau381 aptasensor in 10 patients’ serum samples showed that the aptasensor could screen patients with and without Alzheimer′s disease. The proposed aptasensor has potential for use in clinically diagnosing Alzheimer′s disease in the early stage. MDPI 2019-06-30 /pmc/articles/PMC6784373/ /pubmed/31262001 http://dx.doi.org/10.3390/bios9030084 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Tao, Dan
Shui, Bingqing
Gu, Yingying
Cheng, Jing
Zhang, Weiying
Jaffrezic-Renault, Nicole
Song, Shizhen
Guo, Zhenzhong
Development of a Label-Free Electrochemical Aptasensor for the Detection of Tau381 and its Preliminary Application in AD and Non-AD Patients’ Sera
title Development of a Label-Free Electrochemical Aptasensor for the Detection of Tau381 and its Preliminary Application in AD and Non-AD Patients’ Sera
title_full Development of a Label-Free Electrochemical Aptasensor for the Detection of Tau381 and its Preliminary Application in AD and Non-AD Patients’ Sera
title_fullStr Development of a Label-Free Electrochemical Aptasensor for the Detection of Tau381 and its Preliminary Application in AD and Non-AD Patients’ Sera
title_full_unstemmed Development of a Label-Free Electrochemical Aptasensor for the Detection of Tau381 and its Preliminary Application in AD and Non-AD Patients’ Sera
title_short Development of a Label-Free Electrochemical Aptasensor for the Detection of Tau381 and its Preliminary Application in AD and Non-AD Patients’ Sera
title_sort development of a label-free electrochemical aptasensor for the detection of tau381 and its preliminary application in ad and non-ad patients’ sera
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6784373/
https://www.ncbi.nlm.nih.gov/pubmed/31262001
http://dx.doi.org/10.3390/bios9030084
work_keys_str_mv AT taodan developmentofalabelfreeelectrochemicalaptasensorforthedetectionoftau381anditspreliminaryapplicationinadandnonadpatientssera
AT shuibingqing developmentofalabelfreeelectrochemicalaptasensorforthedetectionoftau381anditspreliminaryapplicationinadandnonadpatientssera
AT guyingying developmentofalabelfreeelectrochemicalaptasensorforthedetectionoftau381anditspreliminaryapplicationinadandnonadpatientssera
AT chengjing developmentofalabelfreeelectrochemicalaptasensorforthedetectionoftau381anditspreliminaryapplicationinadandnonadpatientssera
AT zhangweiying developmentofalabelfreeelectrochemicalaptasensorforthedetectionoftau381anditspreliminaryapplicationinadandnonadpatientssera
AT jaffrezicrenaultnicole developmentofalabelfreeelectrochemicalaptasensorforthedetectionoftau381anditspreliminaryapplicationinadandnonadpatientssera
AT songshizhen developmentofalabelfreeelectrochemicalaptasensorforthedetectionoftau381anditspreliminaryapplicationinadandnonadpatientssera
AT guozhenzhong developmentofalabelfreeelectrochemicalaptasensorforthedetectionoftau381anditspreliminaryapplicationinadandnonadpatientssera