Cargando…
Development of a Label-Free Electrochemical Aptasensor for the Detection of Tau381 and its Preliminary Application in AD and Non-AD Patients’ Sera
The electrochemical aptamer sensor has been designed for detecting tau381, a critical biomarker of Alzheimer′s disease in human serum. The aptasensor is obtained by immobilizing the aptamer on a carboxyl graphene/thionin/gold nanoparticle modified glassy-carbon electrode. As a probe and bridge molec...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6784373/ https://www.ncbi.nlm.nih.gov/pubmed/31262001 http://dx.doi.org/10.3390/bios9030084 |
_version_ | 1783457748604682240 |
---|---|
author | Tao, Dan Shui, Bingqing Gu, Yingying Cheng, Jing Zhang, Weiying Jaffrezic-Renault, Nicole Song, Shizhen Guo, Zhenzhong |
author_facet | Tao, Dan Shui, Bingqing Gu, Yingying Cheng, Jing Zhang, Weiying Jaffrezic-Renault, Nicole Song, Shizhen Guo, Zhenzhong |
author_sort | Tao, Dan |
collection | PubMed |
description | The electrochemical aptamer sensor has been designed for detecting tau381, a critical biomarker of Alzheimer′s disease in human serum. The aptasensor is obtained by immobilizing the aptamer on a carboxyl graphene/thionin/gold nanoparticle modified glassy-carbon electrode. As a probe and bridge molecule, thionin connected carboxyl graphene and gold nanoparticles, and gave the electrical signal. Under optimal conditions, the increment of differential pulse voltammetry signal increased linearly with the logarithm of tau381 concentration in the range from 1.0 pM to 100 pM, and limit of detection was 0.70 pM. The aptasensor reliability was evaluated by determining its selectivity, reproducibility, stability, detection limit, and recovery. Performance analysis of the tau381 aptasensor in 10 patients’ serum samples showed that the aptasensor could screen patients with and without Alzheimer′s disease. The proposed aptasensor has potential for use in clinically diagnosing Alzheimer′s disease in the early stage. |
format | Online Article Text |
id | pubmed-6784373 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-67843732019-10-16 Development of a Label-Free Electrochemical Aptasensor for the Detection of Tau381 and its Preliminary Application in AD and Non-AD Patients’ Sera Tao, Dan Shui, Bingqing Gu, Yingying Cheng, Jing Zhang, Weiying Jaffrezic-Renault, Nicole Song, Shizhen Guo, Zhenzhong Biosensors (Basel) Article The electrochemical aptamer sensor has been designed for detecting tau381, a critical biomarker of Alzheimer′s disease in human serum. The aptasensor is obtained by immobilizing the aptamer on a carboxyl graphene/thionin/gold nanoparticle modified glassy-carbon electrode. As a probe and bridge molecule, thionin connected carboxyl graphene and gold nanoparticles, and gave the electrical signal. Under optimal conditions, the increment of differential pulse voltammetry signal increased linearly with the logarithm of tau381 concentration in the range from 1.0 pM to 100 pM, and limit of detection was 0.70 pM. The aptasensor reliability was evaluated by determining its selectivity, reproducibility, stability, detection limit, and recovery. Performance analysis of the tau381 aptasensor in 10 patients’ serum samples showed that the aptasensor could screen patients with and without Alzheimer′s disease. The proposed aptasensor has potential for use in clinically diagnosing Alzheimer′s disease in the early stage. MDPI 2019-06-30 /pmc/articles/PMC6784373/ /pubmed/31262001 http://dx.doi.org/10.3390/bios9030084 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Tao, Dan Shui, Bingqing Gu, Yingying Cheng, Jing Zhang, Weiying Jaffrezic-Renault, Nicole Song, Shizhen Guo, Zhenzhong Development of a Label-Free Electrochemical Aptasensor for the Detection of Tau381 and its Preliminary Application in AD and Non-AD Patients’ Sera |
title | Development of a Label-Free Electrochemical Aptasensor for the Detection of Tau381 and its Preliminary Application in AD and Non-AD Patients’ Sera |
title_full | Development of a Label-Free Electrochemical Aptasensor for the Detection of Tau381 and its Preliminary Application in AD and Non-AD Patients’ Sera |
title_fullStr | Development of a Label-Free Electrochemical Aptasensor for the Detection of Tau381 and its Preliminary Application in AD and Non-AD Patients’ Sera |
title_full_unstemmed | Development of a Label-Free Electrochemical Aptasensor for the Detection of Tau381 and its Preliminary Application in AD and Non-AD Patients’ Sera |
title_short | Development of a Label-Free Electrochemical Aptasensor for the Detection of Tau381 and its Preliminary Application in AD and Non-AD Patients’ Sera |
title_sort | development of a label-free electrochemical aptasensor for the detection of tau381 and its preliminary application in ad and non-ad patients’ sera |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6784373/ https://www.ncbi.nlm.nih.gov/pubmed/31262001 http://dx.doi.org/10.3390/bios9030084 |
work_keys_str_mv | AT taodan developmentofalabelfreeelectrochemicalaptasensorforthedetectionoftau381anditspreliminaryapplicationinadandnonadpatientssera AT shuibingqing developmentofalabelfreeelectrochemicalaptasensorforthedetectionoftau381anditspreliminaryapplicationinadandnonadpatientssera AT guyingying developmentofalabelfreeelectrochemicalaptasensorforthedetectionoftau381anditspreliminaryapplicationinadandnonadpatientssera AT chengjing developmentofalabelfreeelectrochemicalaptasensorforthedetectionoftau381anditspreliminaryapplicationinadandnonadpatientssera AT zhangweiying developmentofalabelfreeelectrochemicalaptasensorforthedetectionoftau381anditspreliminaryapplicationinadandnonadpatientssera AT jaffrezicrenaultnicole developmentofalabelfreeelectrochemicalaptasensorforthedetectionoftau381anditspreliminaryapplicationinadandnonadpatientssera AT songshizhen developmentofalabelfreeelectrochemicalaptasensorforthedetectionoftau381anditspreliminaryapplicationinadandnonadpatientssera AT guozhenzhong developmentofalabelfreeelectrochemicalaptasensorforthedetectionoftau381anditspreliminaryapplicationinadandnonadpatientssera |