Cargando…
Effectiveness of Ball Attachment Systems in Implant Retained- and Supported-Overdentures: A Three- to Five-Year Retrospective Examination
Purpose: To evaluate implant and prosthetic survival rates, complications, patient satisfaction, and biological outcomes of patients rehabilitated with a ball attachment system for implant retained- and supported-overdentures (IOV), which was in function for 3 to 5 years. Methods: This retrospective...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6784476/ https://www.ncbi.nlm.nih.gov/pubmed/31480546 http://dx.doi.org/10.3390/dj7030084 |
_version_ | 1783457766343442432 |
---|---|
author | Ortensi, Luca Martinolli, Matteo Borromeo, Carlo Ceruso, Francesco Mattia Gargari, Marco Xhanari, Erta Tallarico, Marco |
author_facet | Ortensi, Luca Martinolli, Matteo Borromeo, Carlo Ceruso, Francesco Mattia Gargari, Marco Xhanari, Erta Tallarico, Marco |
author_sort | Ortensi, Luca |
collection | PubMed |
description | Purpose: To evaluate implant and prosthetic survival rates, complications, patient satisfaction, and biological outcomes of patients rehabilitated with a ball attachment system for implant retained- and supported-overdentures (IOV), which was in function for 3 to 5 years. Methods: This retrospective study evaluated data collected from patients treated between April 2001 and May 2018 with IOV on splinted and non-splinted implants and a ball attachment system. Patients were followed for 36 to 206 months (mean follow-up was 128.1 ± 51.9 months). Data were collected at the 3- and 5-year follow-up examination. Outcome measures were implant and prosthetic survival rates, technical complications, marginal bone loss (MBL), oral health impact profile (OHIP), and periodontal parameters (bleeding on probing and plaque index). Results: A total of 46 patients (16 males and 30 females) with 124 implants were included in this study. Twenty-five implant-retained overdentures were delivered on 53 unsplinted implants, while the other 21 patients received an implant-supported overdentures and the implants were splinted. At the five-year follow-up examination, one implant and one prosthesis failed in the unsplinted group, resulting in a cumulative survival rate of 97.8% at the patient level. Two minor technical complications were experienced. Conclusions: Implant overdenture retained or supported by ball attachment systems showed high implant and prosthetic survival and success rates. A low number of complications, high patient satisfaction, and successful biological parameters were experienced in the mid-term follow-up. Data need to be confirmed by further randomized trials. |
format | Online Article Text |
id | pubmed-6784476 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-67844762019-10-16 Effectiveness of Ball Attachment Systems in Implant Retained- and Supported-Overdentures: A Three- to Five-Year Retrospective Examination Ortensi, Luca Martinolli, Matteo Borromeo, Carlo Ceruso, Francesco Mattia Gargari, Marco Xhanari, Erta Tallarico, Marco Dent J (Basel) Article Purpose: To evaluate implant and prosthetic survival rates, complications, patient satisfaction, and biological outcomes of patients rehabilitated with a ball attachment system for implant retained- and supported-overdentures (IOV), which was in function for 3 to 5 years. Methods: This retrospective study evaluated data collected from patients treated between April 2001 and May 2018 with IOV on splinted and non-splinted implants and a ball attachment system. Patients were followed for 36 to 206 months (mean follow-up was 128.1 ± 51.9 months). Data were collected at the 3- and 5-year follow-up examination. Outcome measures were implant and prosthetic survival rates, technical complications, marginal bone loss (MBL), oral health impact profile (OHIP), and periodontal parameters (bleeding on probing and plaque index). Results: A total of 46 patients (16 males and 30 females) with 124 implants were included in this study. Twenty-five implant-retained overdentures were delivered on 53 unsplinted implants, while the other 21 patients received an implant-supported overdentures and the implants were splinted. At the five-year follow-up examination, one implant and one prosthesis failed in the unsplinted group, resulting in a cumulative survival rate of 97.8% at the patient level. Two minor technical complications were experienced. Conclusions: Implant overdenture retained or supported by ball attachment systems showed high implant and prosthetic survival and success rates. A low number of complications, high patient satisfaction, and successful biological parameters were experienced in the mid-term follow-up. Data need to be confirmed by further randomized trials. MDPI 2019-09-01 /pmc/articles/PMC6784476/ /pubmed/31480546 http://dx.doi.org/10.3390/dj7030084 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Ortensi, Luca Martinolli, Matteo Borromeo, Carlo Ceruso, Francesco Mattia Gargari, Marco Xhanari, Erta Tallarico, Marco Effectiveness of Ball Attachment Systems in Implant Retained- and Supported-Overdentures: A Three- to Five-Year Retrospective Examination |
title | Effectiveness of Ball Attachment Systems in Implant Retained- and Supported-Overdentures: A Three- to Five-Year Retrospective Examination |
title_full | Effectiveness of Ball Attachment Systems in Implant Retained- and Supported-Overdentures: A Three- to Five-Year Retrospective Examination |
title_fullStr | Effectiveness of Ball Attachment Systems in Implant Retained- and Supported-Overdentures: A Three- to Five-Year Retrospective Examination |
title_full_unstemmed | Effectiveness of Ball Attachment Systems in Implant Retained- and Supported-Overdentures: A Three- to Five-Year Retrospective Examination |
title_short | Effectiveness of Ball Attachment Systems in Implant Retained- and Supported-Overdentures: A Three- to Five-Year Retrospective Examination |
title_sort | effectiveness of ball attachment systems in implant retained- and supported-overdentures: a three- to five-year retrospective examination |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6784476/ https://www.ncbi.nlm.nih.gov/pubmed/31480546 http://dx.doi.org/10.3390/dj7030084 |
work_keys_str_mv | AT ortensiluca effectivenessofballattachmentsystemsinimplantretainedandsupportedoverdenturesathreetofiveyearretrospectiveexamination AT martinollimatteo effectivenessofballattachmentsystemsinimplantretainedandsupportedoverdenturesathreetofiveyearretrospectiveexamination AT borromeocarlo effectivenessofballattachmentsystemsinimplantretainedandsupportedoverdenturesathreetofiveyearretrospectiveexamination AT cerusofrancescomattia effectivenessofballattachmentsystemsinimplantretainedandsupportedoverdenturesathreetofiveyearretrospectiveexamination AT gargarimarco effectivenessofballattachmentsystemsinimplantretainedandsupportedoverdenturesathreetofiveyearretrospectiveexamination AT xhanarierta effectivenessofballattachmentsystemsinimplantretainedandsupportedoverdenturesathreetofiveyearretrospectiveexamination AT tallaricomarco effectivenessofballattachmentsystemsinimplantretainedandsupportedoverdenturesathreetofiveyearretrospectiveexamination |