Comparison of the removal torque and a histomorphometric evaluation of the RBM treated implants with the RBM followed by laser treated implants: an experimental study in rabbits
BACKGROUND: In the osseointegration of dental implants, the implant surface properties have been reported to be some of the most important critical factors. The effect of implant’s surfaces created by resorbable blast media (RBM) followed by laser ablation on bone tissue reactions was examined using...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Yeungnam University College of Medicine
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6784622/ https://www.ncbi.nlm.nih.gov/pubmed/31620611 http://dx.doi.org/10.12701/yujm.2019.00094 |
_version_ | 1783457778125242368 |
---|---|
author | Park, Eun Young Sohn, Hae Ok Kim, Eun-Kyong |
author_facet | Park, Eun Young Sohn, Hae Ok Kim, Eun-Kyong |
author_sort | Park, Eun Young |
collection | PubMed |
description | BACKGROUND: In the osseointegration of dental implants, the implant surface properties have been reported to be some of the most important critical factors. The effect of implant’s surfaces created by resorbable blast media (RBM) followed by laser ablation on bone tissue reactions was examined using the removal torque test and histomorphometric analysis. METHODS: Two types of dental implants, RBM-laser implants (experimental group) and RBM implants (control group) (CSM implant system, Daegu, Korea; L=6 mm, diameter=3.75 mm) were placed into the right and left distal femoral metaphysis of 17 adult rabbits. Six weeks after placement, removal torque was measured and histomorphometric analysis was performed. RESULTS: The mean removal torque was 24.0±10.2 Ncm and 46.6±16.4 Ncm for the control and test specimens, respectively. The experimental RBM-laser implants had significantly higher removal torque values than the control RBM implants (p=0.013). The mean values of total and cortical bone to implant contact (BIC) were respectively 46.3±10.8% and 65.3±12.5% for the experimental group, and 41.9±18.5% and 57.6±10.6% for the control group. The experimental RBM-laser implants showed a higher degree of total and cortical BIC compared with RBM implants, but there was no statistical significance (p=0.482, 0.225). CONCLUSION: The removal torque and BIC of the test group were higher than those of the control group. In this study, the surface treatment created by RBM treatment followed by laser ablation appears to have a potential in improving bone tissue reactions of dental implants. |
format | Online Article Text |
id | pubmed-6784622 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Yeungnam University College of Medicine |
record_format | MEDLINE/PubMed |
spelling | pubmed-67846222019-10-16 Comparison of the removal torque and a histomorphometric evaluation of the RBM treated implants with the RBM followed by laser treated implants: an experimental study in rabbits Park, Eun Young Sohn, Hae Ok Kim, Eun-Kyong Yeungnam Univ J Med Original Article BACKGROUND: In the osseointegration of dental implants, the implant surface properties have been reported to be some of the most important critical factors. The effect of implant’s surfaces created by resorbable blast media (RBM) followed by laser ablation on bone tissue reactions was examined using the removal torque test and histomorphometric analysis. METHODS: Two types of dental implants, RBM-laser implants (experimental group) and RBM implants (control group) (CSM implant system, Daegu, Korea; L=6 mm, diameter=3.75 mm) were placed into the right and left distal femoral metaphysis of 17 adult rabbits. Six weeks after placement, removal torque was measured and histomorphometric analysis was performed. RESULTS: The mean removal torque was 24.0±10.2 Ncm and 46.6±16.4 Ncm for the control and test specimens, respectively. The experimental RBM-laser implants had significantly higher removal torque values than the control RBM implants (p=0.013). The mean values of total and cortical bone to implant contact (BIC) were respectively 46.3±10.8% and 65.3±12.5% for the experimental group, and 41.9±18.5% and 57.6±10.6% for the control group. The experimental RBM-laser implants showed a higher degree of total and cortical BIC compared with RBM implants, but there was no statistical significance (p=0.482, 0.225). CONCLUSION: The removal torque and BIC of the test group were higher than those of the control group. In this study, the surface treatment created by RBM treatment followed by laser ablation appears to have a potential in improving bone tissue reactions of dental implants. Yeungnam University College of Medicine 2019-01-11 /pmc/articles/PMC6784622/ /pubmed/31620611 http://dx.doi.org/10.12701/yujm.2019.00094 Text en Copyright © 2019 Yeungnam University College of Medicine This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Park, Eun Young Sohn, Hae Ok Kim, Eun-Kyong Comparison of the removal torque and a histomorphometric evaluation of the RBM treated implants with the RBM followed by laser treated implants: an experimental study in rabbits |
title | Comparison of the removal torque and a histomorphometric evaluation of the RBM treated implants with the RBM followed by laser treated implants: an experimental study in rabbits |
title_full | Comparison of the removal torque and a histomorphometric evaluation of the RBM treated implants with the RBM followed by laser treated implants: an experimental study in rabbits |
title_fullStr | Comparison of the removal torque and a histomorphometric evaluation of the RBM treated implants with the RBM followed by laser treated implants: an experimental study in rabbits |
title_full_unstemmed | Comparison of the removal torque and a histomorphometric evaluation of the RBM treated implants with the RBM followed by laser treated implants: an experimental study in rabbits |
title_short | Comparison of the removal torque and a histomorphometric evaluation of the RBM treated implants with the RBM followed by laser treated implants: an experimental study in rabbits |
title_sort | comparison of the removal torque and a histomorphometric evaluation of the rbm treated implants with the rbm followed by laser treated implants: an experimental study in rabbits |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6784622/ https://www.ncbi.nlm.nih.gov/pubmed/31620611 http://dx.doi.org/10.12701/yujm.2019.00094 |
work_keys_str_mv | AT parkeunyoung comparisonoftheremovaltorqueandahistomorphometricevaluationoftherbmtreatedimplantswiththerbmfollowedbylasertreatedimplantsanexperimentalstudyinrabbits AT sohnhaeok comparisonoftheremovaltorqueandahistomorphometricevaluationoftherbmtreatedimplantswiththerbmfollowedbylasertreatedimplantsanexperimentalstudyinrabbits AT kimeunkyong comparisonoftheremovaltorqueandahistomorphometricevaluationoftherbmtreatedimplantswiththerbmfollowedbylasertreatedimplantsanexperimentalstudyinrabbits |