Cargando…
Comparison of Plusoptix S12R photoscreener with cycloplegic retinoscopy and autorefraction in pediatric age group
PURPOSE: To compare refractive measurements of noncycloplegic photoscreener Plusoptix S12R with cycloplegic retinoscopy, noncycloplegic autorefractor, and cycloplegic autorefractor in children. METHODS: The study population (200 eyes of 100 children) was divided into two groups: Group 1 (age 3–7 yea...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6786145/ https://www.ncbi.nlm.nih.gov/pubmed/31546479 http://dx.doi.org/10.4103/ijo.IJO_1465_18 |
_version_ | 1783458015344590848 |
---|---|
author | Saini, Varun Raina, Usha K Gupta, Anika Goyal, Jawahar Lal Anjum, Raffat Saini, Pallavi Gupta, Shantanu Kumar Sharma, Prateeksha |
author_facet | Saini, Varun Raina, Usha K Gupta, Anika Goyal, Jawahar Lal Anjum, Raffat Saini, Pallavi Gupta, Shantanu Kumar Sharma, Prateeksha |
author_sort | Saini, Varun |
collection | PubMed |
description | PURPOSE: To compare refractive measurements of noncycloplegic photoscreener Plusoptix S12R with cycloplegic retinoscopy, noncycloplegic autorefractor, and cycloplegic autorefractor in children. METHODS: The study population (200 eyes of 100 children) was divided into two groups: Group 1 (age 3–7 years) and Group 2 (age 8–15 years). In Group 1, Plusoptix was compared with cycloplegic retinoscopy. In Group 2, Plusoptix was compared with cycloplegic retinoscopy and autorefraction. The second group was made because the younger group was found to be uncooperative for autorefraction. Paired t-test and Pearson's correlation were used for statistical analysis. RESULTS: The mean difference in sphere (DS), spherical equivalent (DSE), and cylinder (DC) between cycloplegic retinoscopy and Plusoptix in Group 1 was 0.68 ± 0.55 (P < 0.001), 0.77 ± 0.61 (P < 0.001), and 0.18 ± 0.28 (P < 0.001), respectively. In Group 2, DS, DSE, and DC between cycloplegic retinoscopy and Plusoptix were 0.86 ± 0.49 (P < 0.001), 0.97 ± 0.51 (P < 0.001), and 0.23 ± 0.28 (P < 0.001); between cycloplegic autorefractor and Plusoptix were 0.69 ± 0.47 (P < 0.001), 0.74 ± 0.49 (P < 0.001), and 0.10 ± 0.31 (P = 0.002); and between noncycloplegic autorefractor and Plusoptix were − 0.25 ± 0.39 (P < 0.001), −0.19 ± 0.41 (P < 0.001), and 0.11 ± 0.31 (P < 0.001), respectively. Pearson's correlation coefficients of S, SE, and C between Plusoptix and cycloplegic retinoscopy were 0.948, 0.938, and 0.924 in Group 1 and 0.972, 0.972, and 0.946 in Group 2, and these values were statistically significant. Bland–Altman plots showed good agreement between cycloplegic retinoscopy and Plusoptix in both groups. Plusoptix gave axis values within 10° of cycloplegic retinoscopy in 81.56% of eyes in Group 1 and in 71.44% of eyes in Group 2. CONCLUSION: Plusoptix photoscreener can be used for prescription of axis of cylinder in children; however, other refractive measurements must be refined by cycloplegic retinoscopy. |
format | Online Article Text |
id | pubmed-6786145 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-67861452019-10-16 Comparison of Plusoptix S12R photoscreener with cycloplegic retinoscopy and autorefraction in pediatric age group Saini, Varun Raina, Usha K Gupta, Anika Goyal, Jawahar Lal Anjum, Raffat Saini, Pallavi Gupta, Shantanu Kumar Sharma, Prateeksha Indian J Ophthalmol Original Article PURPOSE: To compare refractive measurements of noncycloplegic photoscreener Plusoptix S12R with cycloplegic retinoscopy, noncycloplegic autorefractor, and cycloplegic autorefractor in children. METHODS: The study population (200 eyes of 100 children) was divided into two groups: Group 1 (age 3–7 years) and Group 2 (age 8–15 years). In Group 1, Plusoptix was compared with cycloplegic retinoscopy. In Group 2, Plusoptix was compared with cycloplegic retinoscopy and autorefraction. The second group was made because the younger group was found to be uncooperative for autorefraction. Paired t-test and Pearson's correlation were used for statistical analysis. RESULTS: The mean difference in sphere (DS), spherical equivalent (DSE), and cylinder (DC) between cycloplegic retinoscopy and Plusoptix in Group 1 was 0.68 ± 0.55 (P < 0.001), 0.77 ± 0.61 (P < 0.001), and 0.18 ± 0.28 (P < 0.001), respectively. In Group 2, DS, DSE, and DC between cycloplegic retinoscopy and Plusoptix were 0.86 ± 0.49 (P < 0.001), 0.97 ± 0.51 (P < 0.001), and 0.23 ± 0.28 (P < 0.001); between cycloplegic autorefractor and Plusoptix were 0.69 ± 0.47 (P < 0.001), 0.74 ± 0.49 (P < 0.001), and 0.10 ± 0.31 (P = 0.002); and between noncycloplegic autorefractor and Plusoptix were − 0.25 ± 0.39 (P < 0.001), −0.19 ± 0.41 (P < 0.001), and 0.11 ± 0.31 (P < 0.001), respectively. Pearson's correlation coefficients of S, SE, and C between Plusoptix and cycloplegic retinoscopy were 0.948, 0.938, and 0.924 in Group 1 and 0.972, 0.972, and 0.946 in Group 2, and these values were statistically significant. Bland–Altman plots showed good agreement between cycloplegic retinoscopy and Plusoptix in both groups. Plusoptix gave axis values within 10° of cycloplegic retinoscopy in 81.56% of eyes in Group 1 and in 71.44% of eyes in Group 2. CONCLUSION: Plusoptix photoscreener can be used for prescription of axis of cylinder in children; however, other refractive measurements must be refined by cycloplegic retinoscopy. Wolters Kluwer - Medknow 2019-10 /pmc/articles/PMC6786145/ /pubmed/31546479 http://dx.doi.org/10.4103/ijo.IJO_1465_18 Text en Copyright: © 2019 Indian Journal of Ophthalmology http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Saini, Varun Raina, Usha K Gupta, Anika Goyal, Jawahar Lal Anjum, Raffat Saini, Pallavi Gupta, Shantanu Kumar Sharma, Prateeksha Comparison of Plusoptix S12R photoscreener with cycloplegic retinoscopy and autorefraction in pediatric age group |
title | Comparison of Plusoptix S12R photoscreener with cycloplegic retinoscopy and autorefraction in pediatric age group |
title_full | Comparison of Plusoptix S12R photoscreener with cycloplegic retinoscopy and autorefraction in pediatric age group |
title_fullStr | Comparison of Plusoptix S12R photoscreener with cycloplegic retinoscopy and autorefraction in pediatric age group |
title_full_unstemmed | Comparison of Plusoptix S12R photoscreener with cycloplegic retinoscopy and autorefraction in pediatric age group |
title_short | Comparison of Plusoptix S12R photoscreener with cycloplegic retinoscopy and autorefraction in pediatric age group |
title_sort | comparison of plusoptix s12r photoscreener with cycloplegic retinoscopy and autorefraction in pediatric age group |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6786145/ https://www.ncbi.nlm.nih.gov/pubmed/31546479 http://dx.doi.org/10.4103/ijo.IJO_1465_18 |
work_keys_str_mv | AT sainivarun comparisonofplusoptixs12rphotoscreenerwithcycloplegicretinoscopyandautorefractioninpediatricagegroup AT rainaushak comparisonofplusoptixs12rphotoscreenerwithcycloplegicretinoscopyandautorefractioninpediatricagegroup AT guptaanika comparisonofplusoptixs12rphotoscreenerwithcycloplegicretinoscopyandautorefractioninpediatricagegroup AT goyaljawaharlal comparisonofplusoptixs12rphotoscreenerwithcycloplegicretinoscopyandautorefractioninpediatricagegroup AT anjumraffat comparisonofplusoptixs12rphotoscreenerwithcycloplegicretinoscopyandautorefractioninpediatricagegroup AT sainipallavi comparisonofplusoptixs12rphotoscreenerwithcycloplegicretinoscopyandautorefractioninpediatricagegroup AT guptashantanukumar comparisonofplusoptixs12rphotoscreenerwithcycloplegicretinoscopyandautorefractioninpediatricagegroup AT sharmaprateeksha comparisonofplusoptixs12rphotoscreenerwithcycloplegicretinoscopyandautorefractioninpediatricagegroup |