Cargando…

Comparison of Plusoptix S12R photoscreener with cycloplegic retinoscopy and autorefraction in pediatric age group

PURPOSE: To compare refractive measurements of noncycloplegic photoscreener Plusoptix S12R with cycloplegic retinoscopy, noncycloplegic autorefractor, and cycloplegic autorefractor in children. METHODS: The study population (200 eyes of 100 children) was divided into two groups: Group 1 (age 3–7 yea...

Descripción completa

Detalles Bibliográficos
Autores principales: Saini, Varun, Raina, Usha K, Gupta, Anika, Goyal, Jawahar Lal, Anjum, Raffat, Saini, Pallavi, Gupta, Shantanu Kumar, Sharma, Prateeksha
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6786145/
https://www.ncbi.nlm.nih.gov/pubmed/31546479
http://dx.doi.org/10.4103/ijo.IJO_1465_18
_version_ 1783458015344590848
author Saini, Varun
Raina, Usha K
Gupta, Anika
Goyal, Jawahar Lal
Anjum, Raffat
Saini, Pallavi
Gupta, Shantanu Kumar
Sharma, Prateeksha
author_facet Saini, Varun
Raina, Usha K
Gupta, Anika
Goyal, Jawahar Lal
Anjum, Raffat
Saini, Pallavi
Gupta, Shantanu Kumar
Sharma, Prateeksha
author_sort Saini, Varun
collection PubMed
description PURPOSE: To compare refractive measurements of noncycloplegic photoscreener Plusoptix S12R with cycloplegic retinoscopy, noncycloplegic autorefractor, and cycloplegic autorefractor in children. METHODS: The study population (200 eyes of 100 children) was divided into two groups: Group 1 (age 3–7 years) and Group 2 (age 8–15 years). In Group 1, Plusoptix was compared with cycloplegic retinoscopy. In Group 2, Plusoptix was compared with cycloplegic retinoscopy and autorefraction. The second group was made because the younger group was found to be uncooperative for autorefraction. Paired t-test and Pearson's correlation were used for statistical analysis. RESULTS: The mean difference in sphere (DS), spherical equivalent (DSE), and cylinder (DC) between cycloplegic retinoscopy and Plusoptix in Group 1 was 0.68 ± 0.55 (P < 0.001), 0.77 ± 0.61 (P < 0.001), and 0.18 ± 0.28 (P < 0.001), respectively. In Group 2, DS, DSE, and DC between cycloplegic retinoscopy and Plusoptix were 0.86 ± 0.49 (P < 0.001), 0.97 ± 0.51 (P < 0.001), and 0.23 ± 0.28 (P < 0.001); between cycloplegic autorefractor and Plusoptix were 0.69 ± 0.47 (P < 0.001), 0.74 ± 0.49 (P < 0.001), and 0.10 ± 0.31 (P = 0.002); and between noncycloplegic autorefractor and Plusoptix were − 0.25 ± 0.39 (P < 0.001), −0.19 ± 0.41 (P < 0.001), and 0.11 ± 0.31 (P < 0.001), respectively. Pearson's correlation coefficients of S, SE, and C between Plusoptix and cycloplegic retinoscopy were 0.948, 0.938, and 0.924 in Group 1 and 0.972, 0.972, and 0.946 in Group 2, and these values were statistically significant. Bland–Altman plots showed good agreement between cycloplegic retinoscopy and Plusoptix in both groups. Plusoptix gave axis values within 10° of cycloplegic retinoscopy in 81.56% of eyes in Group 1 and in 71.44% of eyes in Group 2. CONCLUSION: Plusoptix photoscreener can be used for prescription of axis of cylinder in children; however, other refractive measurements must be refined by cycloplegic retinoscopy.
format Online
Article
Text
id pubmed-6786145
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-67861452019-10-16 Comparison of Plusoptix S12R photoscreener with cycloplegic retinoscopy and autorefraction in pediatric age group Saini, Varun Raina, Usha K Gupta, Anika Goyal, Jawahar Lal Anjum, Raffat Saini, Pallavi Gupta, Shantanu Kumar Sharma, Prateeksha Indian J Ophthalmol Original Article PURPOSE: To compare refractive measurements of noncycloplegic photoscreener Plusoptix S12R with cycloplegic retinoscopy, noncycloplegic autorefractor, and cycloplegic autorefractor in children. METHODS: The study population (200 eyes of 100 children) was divided into two groups: Group 1 (age 3–7 years) and Group 2 (age 8–15 years). In Group 1, Plusoptix was compared with cycloplegic retinoscopy. In Group 2, Plusoptix was compared with cycloplegic retinoscopy and autorefraction. The second group was made because the younger group was found to be uncooperative for autorefraction. Paired t-test and Pearson's correlation were used for statistical analysis. RESULTS: The mean difference in sphere (DS), spherical equivalent (DSE), and cylinder (DC) between cycloplegic retinoscopy and Plusoptix in Group 1 was 0.68 ± 0.55 (P < 0.001), 0.77 ± 0.61 (P < 0.001), and 0.18 ± 0.28 (P < 0.001), respectively. In Group 2, DS, DSE, and DC between cycloplegic retinoscopy and Plusoptix were 0.86 ± 0.49 (P < 0.001), 0.97 ± 0.51 (P < 0.001), and 0.23 ± 0.28 (P < 0.001); between cycloplegic autorefractor and Plusoptix were 0.69 ± 0.47 (P < 0.001), 0.74 ± 0.49 (P < 0.001), and 0.10 ± 0.31 (P = 0.002); and between noncycloplegic autorefractor and Plusoptix were − 0.25 ± 0.39 (P < 0.001), −0.19 ± 0.41 (P < 0.001), and 0.11 ± 0.31 (P < 0.001), respectively. Pearson's correlation coefficients of S, SE, and C between Plusoptix and cycloplegic retinoscopy were 0.948, 0.938, and 0.924 in Group 1 and 0.972, 0.972, and 0.946 in Group 2, and these values were statistically significant. Bland–Altman plots showed good agreement between cycloplegic retinoscopy and Plusoptix in both groups. Plusoptix gave axis values within 10° of cycloplegic retinoscopy in 81.56% of eyes in Group 1 and in 71.44% of eyes in Group 2. CONCLUSION: Plusoptix photoscreener can be used for prescription of axis of cylinder in children; however, other refractive measurements must be refined by cycloplegic retinoscopy. Wolters Kluwer - Medknow 2019-10 /pmc/articles/PMC6786145/ /pubmed/31546479 http://dx.doi.org/10.4103/ijo.IJO_1465_18 Text en Copyright: © 2019 Indian Journal of Ophthalmology http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Saini, Varun
Raina, Usha K
Gupta, Anika
Goyal, Jawahar Lal
Anjum, Raffat
Saini, Pallavi
Gupta, Shantanu Kumar
Sharma, Prateeksha
Comparison of Plusoptix S12R photoscreener with cycloplegic retinoscopy and autorefraction in pediatric age group
title Comparison of Plusoptix S12R photoscreener with cycloplegic retinoscopy and autorefraction in pediatric age group
title_full Comparison of Plusoptix S12R photoscreener with cycloplegic retinoscopy and autorefraction in pediatric age group
title_fullStr Comparison of Plusoptix S12R photoscreener with cycloplegic retinoscopy and autorefraction in pediatric age group
title_full_unstemmed Comparison of Plusoptix S12R photoscreener with cycloplegic retinoscopy and autorefraction in pediatric age group
title_short Comparison of Plusoptix S12R photoscreener with cycloplegic retinoscopy and autorefraction in pediatric age group
title_sort comparison of plusoptix s12r photoscreener with cycloplegic retinoscopy and autorefraction in pediatric age group
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6786145/
https://www.ncbi.nlm.nih.gov/pubmed/31546479
http://dx.doi.org/10.4103/ijo.IJO_1465_18
work_keys_str_mv AT sainivarun comparisonofplusoptixs12rphotoscreenerwithcycloplegicretinoscopyandautorefractioninpediatricagegroup
AT rainaushak comparisonofplusoptixs12rphotoscreenerwithcycloplegicretinoscopyandautorefractioninpediatricagegroup
AT guptaanika comparisonofplusoptixs12rphotoscreenerwithcycloplegicretinoscopyandautorefractioninpediatricagegroup
AT goyaljawaharlal comparisonofplusoptixs12rphotoscreenerwithcycloplegicretinoscopyandautorefractioninpediatricagegroup
AT anjumraffat comparisonofplusoptixs12rphotoscreenerwithcycloplegicretinoscopyandautorefractioninpediatricagegroup
AT sainipallavi comparisonofplusoptixs12rphotoscreenerwithcycloplegicretinoscopyandautorefractioninpediatricagegroup
AT guptashantanukumar comparisonofplusoptixs12rphotoscreenerwithcycloplegicretinoscopyandautorefractioninpediatricagegroup
AT sharmaprateeksha comparisonofplusoptixs12rphotoscreenerwithcycloplegicretinoscopyandautorefractioninpediatricagegroup