Cargando…
A Reinforced Endotracheal Tube Completely Severed by a Patient Bite and Lodged in the Right Main Bronchus
Reinforced endotracheal tubes (ETTs) are designed to resist kinking or compression. However, these have a potential risk of being obstructed or severed by a patient’s bite. We report a case in which a reinforced ETT was severed by tube-bite while the patient was in the prone position during an inten...
Autores principales: | Yoon, Susie, Choo, Hyunjung, Kim, Se Eun, Kwon, Heeyeon, Lee, Hannah |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Society of Critical Care Medicine
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6786742/ https://www.ncbi.nlm.nih.gov/pubmed/31723618 http://dx.doi.org/10.4266/kjccm.2016.00437 |
Ejemplares similares
-
Polycarbophil Calcium Lodged in the Bronchus
por: Enokido, Takayoshi, et al.
Publicado: (2017) -
Loss of integrity of a reinforced endotracheal tube by patient bite
por: Jain, Rashmi, et al.
Publicado: (2013) -
Fiber-Optic-Assisted Endotracheal Intubation Complicated by Iatrogenic Right Main Bronchus Obstruction
por: Kumar, Sanjay, et al.
Publicado: (2021) -
Iatrogenic Left Main Bronchus Injury following Atraumatic Double Lumen Endotracheal Tube Placement
por: Hartman, William R., et al.
Publicado: (2013) -
Right Main Bronchus Rupture Presenting with Pneumoperitoneum
por: Hong, Seok Beom, et al.
Publicado: (2018)