Cargando…
Diagnostic Accuracy of Multi-Parametric Magnetic Resonance Imaging for Tumor Staging of Bladder Cancer: Meta-Analysis
Purpose: Evaluate the diagnostic accuracy of multi-parametric magnetic resonance imaging (mp-MRI) for local staging of bladder cancer (BCa). Materials and Methods: The databases of PubMed, Web of Science, Wanfang, and CNKI were searched for related literatures about BCa diagnosed by mp-MRI from Janu...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6788297/ https://www.ncbi.nlm.nih.gov/pubmed/31637213 http://dx.doi.org/10.3389/fonc.2019.00981 |
_version_ | 1783458456303304704 |
---|---|
author | Zhang, Nieke Wang, Xiaoyan Wang, Chunying Chen, Shuqiu Wu, Jianping Zhang, Guangyuan Zhu, Weidong Liu, Jing Xu, Bin Du, Mulong Chen, Ming |
author_facet | Zhang, Nieke Wang, Xiaoyan Wang, Chunying Chen, Shuqiu Wu, Jianping Zhang, Guangyuan Zhu, Weidong Liu, Jing Xu, Bin Du, Mulong Chen, Ming |
author_sort | Zhang, Nieke |
collection | PubMed |
description | Purpose: Evaluate the diagnostic accuracy of multi-parametric magnetic resonance imaging (mp-MRI) for local staging of bladder cancer (BCa). Materials and Methods: The databases of PubMed, Web of Science, Wanfang, and CNKI were searched for related literatures about BCa diagnosed by mp-MRI from January 1, 2000 to April 12, 2019. The strict inclusion and exclusion criteria were set up to extract records. The Quality Assessment of Diagnostic Accuracy Studies (QUADAS)-2 was used to evaluate quality of the candidate studies. The pooled sensitivity, specificity, positive likelihood ratio (+LR), negative likelihood ratio (−LR), and diagnostic odds ratio (DOR) were calculated to assess the diagnostic authenticity of mp-MRI. The summarized receiver operating characteristic (SROC) curve corresponding with the area under the curve (AUC) were analyzed to comprehensively evacuate the diagnostic value of mp-MRI. Results: A total of 140 studies were retrieved by computer-based searching. After quality control, 4 studies with 259 patients were enrolled for meta-analysis. The pooled results showed 0.84 of sensitivity [95% confidence interval (CI) = 0.79-0.89], 0.91 of specificity (95% CI = 0.87–0.93), 8.24 of +LR (95% CI = 4.87–13.92), 0.18 of –LR (95% CI = 0.10–0.31), 49.42 of DOR (95% CI = 19.07–128.09), and 0.946 of AUC. The Spearman correlation analysis found no threshold effect (p = 0.684). A significant heterogeneity existed among 4 included studies with sensitivity (I(2) = 65.7%), specificity (I(2) = 60.0%) and diagnostic OR (I(2) = 67.5%). The Begg's test (p = 0.497) and the egger's test (p = 0.337) found no publication bias. Conclusion: mp-MRI acts a good diagnostic performance for bladder cancer. It is plausible that mpMRIs can be used as an important method for bladder cancer staging. |
format | Online Article Text |
id | pubmed-6788297 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-67882972019-10-21 Diagnostic Accuracy of Multi-Parametric Magnetic Resonance Imaging for Tumor Staging of Bladder Cancer: Meta-Analysis Zhang, Nieke Wang, Xiaoyan Wang, Chunying Chen, Shuqiu Wu, Jianping Zhang, Guangyuan Zhu, Weidong Liu, Jing Xu, Bin Du, Mulong Chen, Ming Front Oncol Oncology Purpose: Evaluate the diagnostic accuracy of multi-parametric magnetic resonance imaging (mp-MRI) for local staging of bladder cancer (BCa). Materials and Methods: The databases of PubMed, Web of Science, Wanfang, and CNKI were searched for related literatures about BCa diagnosed by mp-MRI from January 1, 2000 to April 12, 2019. The strict inclusion and exclusion criteria were set up to extract records. The Quality Assessment of Diagnostic Accuracy Studies (QUADAS)-2 was used to evaluate quality of the candidate studies. The pooled sensitivity, specificity, positive likelihood ratio (+LR), negative likelihood ratio (−LR), and diagnostic odds ratio (DOR) were calculated to assess the diagnostic authenticity of mp-MRI. The summarized receiver operating characteristic (SROC) curve corresponding with the area under the curve (AUC) were analyzed to comprehensively evacuate the diagnostic value of mp-MRI. Results: A total of 140 studies were retrieved by computer-based searching. After quality control, 4 studies with 259 patients were enrolled for meta-analysis. The pooled results showed 0.84 of sensitivity [95% confidence interval (CI) = 0.79-0.89], 0.91 of specificity (95% CI = 0.87–0.93), 8.24 of +LR (95% CI = 4.87–13.92), 0.18 of –LR (95% CI = 0.10–0.31), 49.42 of DOR (95% CI = 19.07–128.09), and 0.946 of AUC. The Spearman correlation analysis found no threshold effect (p = 0.684). A significant heterogeneity existed among 4 included studies with sensitivity (I(2) = 65.7%), specificity (I(2) = 60.0%) and diagnostic OR (I(2) = 67.5%). The Begg's test (p = 0.497) and the egger's test (p = 0.337) found no publication bias. Conclusion: mp-MRI acts a good diagnostic performance for bladder cancer. It is plausible that mpMRIs can be used as an important method for bladder cancer staging. Frontiers Media S.A. 2019-10-04 /pmc/articles/PMC6788297/ /pubmed/31637213 http://dx.doi.org/10.3389/fonc.2019.00981 Text en Copyright © 2019 Zhang, Wang, Wang, Chen, Wu, Zhang, Zhu, Liu, Xu, Du and Chen. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Oncology Zhang, Nieke Wang, Xiaoyan Wang, Chunying Chen, Shuqiu Wu, Jianping Zhang, Guangyuan Zhu, Weidong Liu, Jing Xu, Bin Du, Mulong Chen, Ming Diagnostic Accuracy of Multi-Parametric Magnetic Resonance Imaging for Tumor Staging of Bladder Cancer: Meta-Analysis |
title | Diagnostic Accuracy of Multi-Parametric Magnetic Resonance Imaging for Tumor Staging of Bladder Cancer: Meta-Analysis |
title_full | Diagnostic Accuracy of Multi-Parametric Magnetic Resonance Imaging for Tumor Staging of Bladder Cancer: Meta-Analysis |
title_fullStr | Diagnostic Accuracy of Multi-Parametric Magnetic Resonance Imaging for Tumor Staging of Bladder Cancer: Meta-Analysis |
title_full_unstemmed | Diagnostic Accuracy of Multi-Parametric Magnetic Resonance Imaging for Tumor Staging of Bladder Cancer: Meta-Analysis |
title_short | Diagnostic Accuracy of Multi-Parametric Magnetic Resonance Imaging for Tumor Staging of Bladder Cancer: Meta-Analysis |
title_sort | diagnostic accuracy of multi-parametric magnetic resonance imaging for tumor staging of bladder cancer: meta-analysis |
topic | Oncology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6788297/ https://www.ncbi.nlm.nih.gov/pubmed/31637213 http://dx.doi.org/10.3389/fonc.2019.00981 |
work_keys_str_mv | AT zhangnieke diagnosticaccuracyofmultiparametricmagneticresonanceimagingfortumorstagingofbladdercancermetaanalysis AT wangxiaoyan diagnosticaccuracyofmultiparametricmagneticresonanceimagingfortumorstagingofbladdercancermetaanalysis AT wangchunying diagnosticaccuracyofmultiparametricmagneticresonanceimagingfortumorstagingofbladdercancermetaanalysis AT chenshuqiu diagnosticaccuracyofmultiparametricmagneticresonanceimagingfortumorstagingofbladdercancermetaanalysis AT wujianping diagnosticaccuracyofmultiparametricmagneticresonanceimagingfortumorstagingofbladdercancermetaanalysis AT zhangguangyuan diagnosticaccuracyofmultiparametricmagneticresonanceimagingfortumorstagingofbladdercancermetaanalysis AT zhuweidong diagnosticaccuracyofmultiparametricmagneticresonanceimagingfortumorstagingofbladdercancermetaanalysis AT liujing diagnosticaccuracyofmultiparametricmagneticresonanceimagingfortumorstagingofbladdercancermetaanalysis AT xubin diagnosticaccuracyofmultiparametricmagneticresonanceimagingfortumorstagingofbladdercancermetaanalysis AT dumulong diagnosticaccuracyofmultiparametricmagneticresonanceimagingfortumorstagingofbladdercancermetaanalysis AT chenming diagnosticaccuracyofmultiparametricmagneticresonanceimagingfortumorstagingofbladdercancermetaanalysis |