Cargando…

Diagnostic Accuracy of Multi-Parametric Magnetic Resonance Imaging for Tumor Staging of Bladder Cancer: Meta-Analysis

Purpose: Evaluate the diagnostic accuracy of multi-parametric magnetic resonance imaging (mp-MRI) for local staging of bladder cancer (BCa). Materials and Methods: The databases of PubMed, Web of Science, Wanfang, and CNKI were searched for related literatures about BCa diagnosed by mp-MRI from Janu...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Nieke, Wang, Xiaoyan, Wang, Chunying, Chen, Shuqiu, Wu, Jianping, Zhang, Guangyuan, Zhu, Weidong, Liu, Jing, Xu, Bin, Du, Mulong, Chen, Ming
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6788297/
https://www.ncbi.nlm.nih.gov/pubmed/31637213
http://dx.doi.org/10.3389/fonc.2019.00981
_version_ 1783458456303304704
author Zhang, Nieke
Wang, Xiaoyan
Wang, Chunying
Chen, Shuqiu
Wu, Jianping
Zhang, Guangyuan
Zhu, Weidong
Liu, Jing
Xu, Bin
Du, Mulong
Chen, Ming
author_facet Zhang, Nieke
Wang, Xiaoyan
Wang, Chunying
Chen, Shuqiu
Wu, Jianping
Zhang, Guangyuan
Zhu, Weidong
Liu, Jing
Xu, Bin
Du, Mulong
Chen, Ming
author_sort Zhang, Nieke
collection PubMed
description Purpose: Evaluate the diagnostic accuracy of multi-parametric magnetic resonance imaging (mp-MRI) for local staging of bladder cancer (BCa). Materials and Methods: The databases of PubMed, Web of Science, Wanfang, and CNKI were searched for related literatures about BCa diagnosed by mp-MRI from January 1, 2000 to April 12, 2019. The strict inclusion and exclusion criteria were set up to extract records. The Quality Assessment of Diagnostic Accuracy Studies (QUADAS)-2 was used to evaluate quality of the candidate studies. The pooled sensitivity, specificity, positive likelihood ratio (+LR), negative likelihood ratio (−LR), and diagnostic odds ratio (DOR) were calculated to assess the diagnostic authenticity of mp-MRI. The summarized receiver operating characteristic (SROC) curve corresponding with the area under the curve (AUC) were analyzed to comprehensively evacuate the diagnostic value of mp-MRI. Results: A total of 140 studies were retrieved by computer-based searching. After quality control, 4 studies with 259 patients were enrolled for meta-analysis. The pooled results showed 0.84 of sensitivity [95% confidence interval (CI) = 0.79-0.89], 0.91 of specificity (95% CI = 0.87–0.93), 8.24 of +LR (95% CI = 4.87–13.92), 0.18 of –LR (95% CI = 0.10–0.31), 49.42 of DOR (95% CI = 19.07–128.09), and 0.946 of AUC. The Spearman correlation analysis found no threshold effect (p = 0.684). A significant heterogeneity existed among 4 included studies with sensitivity (I(2) = 65.7%), specificity (I(2) = 60.0%) and diagnostic OR (I(2) = 67.5%). The Begg's test (p = 0.497) and the egger's test (p = 0.337) found no publication bias. Conclusion: mp-MRI acts a good diagnostic performance for bladder cancer. It is plausible that mpMRIs can be used as an important method for bladder cancer staging.
format Online
Article
Text
id pubmed-6788297
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-67882972019-10-21 Diagnostic Accuracy of Multi-Parametric Magnetic Resonance Imaging for Tumor Staging of Bladder Cancer: Meta-Analysis Zhang, Nieke Wang, Xiaoyan Wang, Chunying Chen, Shuqiu Wu, Jianping Zhang, Guangyuan Zhu, Weidong Liu, Jing Xu, Bin Du, Mulong Chen, Ming Front Oncol Oncology Purpose: Evaluate the diagnostic accuracy of multi-parametric magnetic resonance imaging (mp-MRI) for local staging of bladder cancer (BCa). Materials and Methods: The databases of PubMed, Web of Science, Wanfang, and CNKI were searched for related literatures about BCa diagnosed by mp-MRI from January 1, 2000 to April 12, 2019. The strict inclusion and exclusion criteria were set up to extract records. The Quality Assessment of Diagnostic Accuracy Studies (QUADAS)-2 was used to evaluate quality of the candidate studies. The pooled sensitivity, specificity, positive likelihood ratio (+LR), negative likelihood ratio (−LR), and diagnostic odds ratio (DOR) were calculated to assess the diagnostic authenticity of mp-MRI. The summarized receiver operating characteristic (SROC) curve corresponding with the area under the curve (AUC) were analyzed to comprehensively evacuate the diagnostic value of mp-MRI. Results: A total of 140 studies were retrieved by computer-based searching. After quality control, 4 studies with 259 patients were enrolled for meta-analysis. The pooled results showed 0.84 of sensitivity [95% confidence interval (CI) = 0.79-0.89], 0.91 of specificity (95% CI = 0.87–0.93), 8.24 of +LR (95% CI = 4.87–13.92), 0.18 of –LR (95% CI = 0.10–0.31), 49.42 of DOR (95% CI = 19.07–128.09), and 0.946 of AUC. The Spearman correlation analysis found no threshold effect (p = 0.684). A significant heterogeneity existed among 4 included studies with sensitivity (I(2) = 65.7%), specificity (I(2) = 60.0%) and diagnostic OR (I(2) = 67.5%). The Begg's test (p = 0.497) and the egger's test (p = 0.337) found no publication bias. Conclusion: mp-MRI acts a good diagnostic performance for bladder cancer. It is plausible that mpMRIs can be used as an important method for bladder cancer staging. Frontiers Media S.A. 2019-10-04 /pmc/articles/PMC6788297/ /pubmed/31637213 http://dx.doi.org/10.3389/fonc.2019.00981 Text en Copyright © 2019 Zhang, Wang, Wang, Chen, Wu, Zhang, Zhu, Liu, Xu, Du and Chen. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Oncology
Zhang, Nieke
Wang, Xiaoyan
Wang, Chunying
Chen, Shuqiu
Wu, Jianping
Zhang, Guangyuan
Zhu, Weidong
Liu, Jing
Xu, Bin
Du, Mulong
Chen, Ming
Diagnostic Accuracy of Multi-Parametric Magnetic Resonance Imaging for Tumor Staging of Bladder Cancer: Meta-Analysis
title Diagnostic Accuracy of Multi-Parametric Magnetic Resonance Imaging for Tumor Staging of Bladder Cancer: Meta-Analysis
title_full Diagnostic Accuracy of Multi-Parametric Magnetic Resonance Imaging for Tumor Staging of Bladder Cancer: Meta-Analysis
title_fullStr Diagnostic Accuracy of Multi-Parametric Magnetic Resonance Imaging for Tumor Staging of Bladder Cancer: Meta-Analysis
title_full_unstemmed Diagnostic Accuracy of Multi-Parametric Magnetic Resonance Imaging for Tumor Staging of Bladder Cancer: Meta-Analysis
title_short Diagnostic Accuracy of Multi-Parametric Magnetic Resonance Imaging for Tumor Staging of Bladder Cancer: Meta-Analysis
title_sort diagnostic accuracy of multi-parametric magnetic resonance imaging for tumor staging of bladder cancer: meta-analysis
topic Oncology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6788297/
https://www.ncbi.nlm.nih.gov/pubmed/31637213
http://dx.doi.org/10.3389/fonc.2019.00981
work_keys_str_mv AT zhangnieke diagnosticaccuracyofmultiparametricmagneticresonanceimagingfortumorstagingofbladdercancermetaanalysis
AT wangxiaoyan diagnosticaccuracyofmultiparametricmagneticresonanceimagingfortumorstagingofbladdercancermetaanalysis
AT wangchunying diagnosticaccuracyofmultiparametricmagneticresonanceimagingfortumorstagingofbladdercancermetaanalysis
AT chenshuqiu diagnosticaccuracyofmultiparametricmagneticresonanceimagingfortumorstagingofbladdercancermetaanalysis
AT wujianping diagnosticaccuracyofmultiparametricmagneticresonanceimagingfortumorstagingofbladdercancermetaanalysis
AT zhangguangyuan diagnosticaccuracyofmultiparametricmagneticresonanceimagingfortumorstagingofbladdercancermetaanalysis
AT zhuweidong diagnosticaccuracyofmultiparametricmagneticresonanceimagingfortumorstagingofbladdercancermetaanalysis
AT liujing diagnosticaccuracyofmultiparametricmagneticresonanceimagingfortumorstagingofbladdercancermetaanalysis
AT xubin diagnosticaccuracyofmultiparametricmagneticresonanceimagingfortumorstagingofbladdercancermetaanalysis
AT dumulong diagnosticaccuracyofmultiparametricmagneticresonanceimagingfortumorstagingofbladdercancermetaanalysis
AT chenming diagnosticaccuracyofmultiparametricmagneticresonanceimagingfortumorstagingofbladdercancermetaanalysis