Cargando…

A psychoacoustic application for the adjustment of electrical hearing thresholds in cochlear implant patients

OBJECTIVE: Fitting cochlear implants, especially the precise determination of electrical hearing thresholds, is a time-consuming and complex task for patients as well as audiologists. Aim of the study was to develop a method that enables cochlear implant (CI) patients to determine their electrical h...

Descripción completa

Detalles Bibliográficos
Autores principales: Plesch, Johannes, Ernst, Benjamin P., Strieth, Sebastian, Rader, Tobias
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6788687/
https://www.ncbi.nlm.nih.gov/pubmed/31603927
http://dx.doi.org/10.1371/journal.pone.0223625
_version_ 1783458513679286272
author Plesch, Johannes
Ernst, Benjamin P.
Strieth, Sebastian
Rader, Tobias
author_facet Plesch, Johannes
Ernst, Benjamin P.
Strieth, Sebastian
Rader, Tobias
author_sort Plesch, Johannes
collection PubMed
description OBJECTIVE: Fitting cochlear implants, especially the precise determination of electrical hearing thresholds, is a time-consuming and complex task for patients as well as audiologists. Aim of the study was to develop a method that enables cochlear implant (CI) patients to determine their electrical hearing thresholds precisely and independently. Applicability and impact of this method on speech perception in noise at soft speech levels were evaluated. METHOD: An adaptive psychoacoustic procedure for precise hearing threshold determination (precT) was implemented using MatLab (MathWorks) and a graphical user interface was created. Sound signals were calibrated with a CIC4-Implant-Decoder. Study design: A prospective study including 15 experienced adult cochlear implant users was conducted. Electrical hearing thresholds were determined using the automated precT procedure (auto-precT). Speech perception in noise at 50 dB SPL presentation levels was measured for three conditions: (P1) T-levels kept at the previously established T-levels; (P2) T-levels set to the hearing thresholds determined using auto-precT application; (P3) T-levels set 10 cu below the values determined with auto-precT. RESULTS: All subjects were able to perform the auto-precT application independently. T-levels were altered on average by an absolute value of 10.5 cu using auto-precT. Median speech reception thresholds were significantly improved from 2.5 dB SNR (P1) to 1.6 dB SNR (P2, p = 0.02). Speech perception was lowest using the globally lowered T-levels, median 2.9 dB SNR (P3, not significant compared to P1 and P2). CONCLUSION: The applicability of the developed auto-precT application was confirmed in the present clinical study. Patients benefited from adjusting previously established T-levels to the threshold levels determined by the auto-precT application. The integration of the application in the clinical fitting routine as well as a remote fitting software approach is recommended. Furthermore, future possibilities of auto-precT include the implementation of the application on tablets or smart phones.
format Online
Article
Text
id pubmed-6788687
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-67886872019-10-20 A psychoacoustic application for the adjustment of electrical hearing thresholds in cochlear implant patients Plesch, Johannes Ernst, Benjamin P. Strieth, Sebastian Rader, Tobias PLoS One Research Article OBJECTIVE: Fitting cochlear implants, especially the precise determination of electrical hearing thresholds, is a time-consuming and complex task for patients as well as audiologists. Aim of the study was to develop a method that enables cochlear implant (CI) patients to determine their electrical hearing thresholds precisely and independently. Applicability and impact of this method on speech perception in noise at soft speech levels were evaluated. METHOD: An adaptive psychoacoustic procedure for precise hearing threshold determination (precT) was implemented using MatLab (MathWorks) and a graphical user interface was created. Sound signals were calibrated with a CIC4-Implant-Decoder. Study design: A prospective study including 15 experienced adult cochlear implant users was conducted. Electrical hearing thresholds were determined using the automated precT procedure (auto-precT). Speech perception in noise at 50 dB SPL presentation levels was measured for three conditions: (P1) T-levels kept at the previously established T-levels; (P2) T-levels set to the hearing thresholds determined using auto-precT application; (P3) T-levels set 10 cu below the values determined with auto-precT. RESULTS: All subjects were able to perform the auto-precT application independently. T-levels were altered on average by an absolute value of 10.5 cu using auto-precT. Median speech reception thresholds were significantly improved from 2.5 dB SNR (P1) to 1.6 dB SNR (P2, p = 0.02). Speech perception was lowest using the globally lowered T-levels, median 2.9 dB SNR (P3, not significant compared to P1 and P2). CONCLUSION: The applicability of the developed auto-precT application was confirmed in the present clinical study. Patients benefited from adjusting previously established T-levels to the threshold levels determined by the auto-precT application. The integration of the application in the clinical fitting routine as well as a remote fitting software approach is recommended. Furthermore, future possibilities of auto-precT include the implementation of the application on tablets or smart phones. Public Library of Science 2019-10-11 /pmc/articles/PMC6788687/ /pubmed/31603927 http://dx.doi.org/10.1371/journal.pone.0223625 Text en © 2019 Plesch et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Plesch, Johannes
Ernst, Benjamin P.
Strieth, Sebastian
Rader, Tobias
A psychoacoustic application for the adjustment of electrical hearing thresholds in cochlear implant patients
title A psychoacoustic application for the adjustment of electrical hearing thresholds in cochlear implant patients
title_full A psychoacoustic application for the adjustment of electrical hearing thresholds in cochlear implant patients
title_fullStr A psychoacoustic application for the adjustment of electrical hearing thresholds in cochlear implant patients
title_full_unstemmed A psychoacoustic application for the adjustment of electrical hearing thresholds in cochlear implant patients
title_short A psychoacoustic application for the adjustment of electrical hearing thresholds in cochlear implant patients
title_sort psychoacoustic application for the adjustment of electrical hearing thresholds in cochlear implant patients
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6788687/
https://www.ncbi.nlm.nih.gov/pubmed/31603927
http://dx.doi.org/10.1371/journal.pone.0223625
work_keys_str_mv AT pleschjohannes apsychoacousticapplicationfortheadjustmentofelectricalhearingthresholdsincochlearimplantpatients
AT ernstbenjaminp apsychoacousticapplicationfortheadjustmentofelectricalhearingthresholdsincochlearimplantpatients
AT striethsebastian apsychoacousticapplicationfortheadjustmentofelectricalhearingthresholdsincochlearimplantpatients
AT radertobias apsychoacousticapplicationfortheadjustmentofelectricalhearingthresholdsincochlearimplantpatients
AT pleschjohannes psychoacousticapplicationfortheadjustmentofelectricalhearingthresholdsincochlearimplantpatients
AT ernstbenjaminp psychoacousticapplicationfortheadjustmentofelectricalhearingthresholdsincochlearimplantpatients
AT striethsebastian psychoacousticapplicationfortheadjustmentofelectricalhearingthresholdsincochlearimplantpatients
AT radertobias psychoacousticapplicationfortheadjustmentofelectricalhearingthresholdsincochlearimplantpatients