Development and validation of a methotrexate adherence assay

BACKGROUND: The first-line therapy for rheumatoid arthritis (RA) is weekly oral methotrexate (MTX) at low dosages (7.5–25 mg/week). However, ~40% of patients are non-adherent which may explain why some do not respond and need to start more expensive biological therapies. To monitor adherence more ac...

Descripción completa

Detalles Bibliográficos
Autores principales: Bluett, James, Riba-Garcia, Isabel, Verstappen, Suzanne M M, Wendling, Thierry, Ogungbenro, Kayode, Unwin, Richard D, Barton, Anne
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BMJ Publishing Group 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6788879/
https://www.ncbi.nlm.nih.gov/pubmed/31167761
http://dx.doi.org/10.1136/annrheumdis-2019-215446
Descripción
Sumario:BACKGROUND: The first-line therapy for rheumatoid arthritis (RA) is weekly oral methotrexate (MTX) at low dosages (7.5–25 mg/week). However, ~40% of patients are non-adherent which may explain why some do not respond and need to start more expensive biological therapies. To monitor adherence more accurately and develop strategies to improve it, a validated objective MTX adherence test is required. OBJECTIVE: To develop and validate the diagnostic accuracy of a novel MTX adherence assay using high-performance liquid chromatography–selected reaction monitoring– mass spectrometry (HPLC-SRM-MS) based biochemical analysis of drug levels. METHODS: 20 patients with RA underwent MTX pharmacokinetic assessment using HPLC-SRM-MS MTX plasma concentration analysis over a 6-day period. Directly observed therapy was the reference standard. Pharmacokinetic model validation was performed using independent plasma samples from real-world patients (n=50) with self-reported times of drug administration. Following assay optimisation, the sensitivity of the assay to detect adherence was established using samples from an observational cohort study (n=138). RESULTS: A two-compartment pharmacokinetic model was developed and validated. Simulations described the sensitivity required for MTX detection over 7 days; subsequent assay optimisation and retesting of samples confirmed that all patients were correctly identified as MTX adherers. Using real-world samples, the assays sensitivity was 95%. CONCLUSION: Non-adherence to MTX is common and can have a significant effect on disease activity. HPLC-SRM-MS plasma analysis accurately detects MTX adherence. The validated objective test could easily be used in clinic to identify patients requiring adherence support.