Cargando…

Repair of the portal vein using a hepatic ligamentum teres patch for laparoscopic pancreatoduodenectomy: A case report

BACKGROUND: Laparoscopic pancreatoduodenectomy (LPD) has been developed gradually with the advances in surgical laparoscopic techniques. It is technically challenging to perform LPD with portal vein resection and reconstruction. CASE SUMMARY: A 71-year-old female patient was diagnosed with distal ch...

Descripción completa

Detalles Bibliográficos
Autores principales: Wei, Qiang, Chen, Qiang-Pu, Guan, Qing-Hai, Zhu, Wen-Tao
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Baishideng Publishing Group Inc 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6789404/
https://www.ncbi.nlm.nih.gov/pubmed/31616706
http://dx.doi.org/10.12998/wjcc.v7.i18.2879
_version_ 1783458607413592064
author Wei, Qiang
Chen, Qiang-Pu
Guan, Qing-Hai
Zhu, Wen-Tao
author_facet Wei, Qiang
Chen, Qiang-Pu
Guan, Qing-Hai
Zhu, Wen-Tao
author_sort Wei, Qiang
collection PubMed
description BACKGROUND: Laparoscopic pancreatoduodenectomy (LPD) has been developed gradually with the advances in surgical laparoscopic techniques. It is technically challenging to perform LPD with portal vein resection and reconstruction. CASE SUMMARY: A 71-year-old female patient was diagnosed with distal cholangiocarcinoma. After preoperative examination and rigorous preoperative preparation, the patient underwent LPD using 3D laparoscopy on July 17, 2018. During the surgery, we found that the tumor invaded the right wall of the portal vein; thus, pancreaticoduodenectomy combined with partial portal vein wall resection was performed. The defect of the portal vein wall was approximately 2.5 cm × 1.0 cm. The hepatic ligamentum teres was excised by laparoscopy and then recanalized in vitro. Following recanalization, the hepatic ligamentum teres was cut longitudinally and then trimmed into vascular patches that were then used to reconstruct the defect of the portal vein through 3D laparoscopy. The operative time was 560 min, and intraoperative blood loss was 100 mL. The duration of the blood occlusion time was 63 min. No blood transfusion was required. The patient underwent enhanced recovery after surgery procedures after the operation. The patient was discharged on postoperative day 11. Follow-up for 6 months after discharge showed no stenosis of the portal vein and good patency of blood flow. CONCLUSION: It is safe and feasible to use the hepatic ligamentum teres patch to repair portal vein in LPD. However, the long-term patency of this technique for venous reconstruction requires further investigation.
format Online
Article
Text
id pubmed-6789404
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Baishideng Publishing Group Inc
record_format MEDLINE/PubMed
spelling pubmed-67894042019-10-15 Repair of the portal vein using a hepatic ligamentum teres patch for laparoscopic pancreatoduodenectomy: A case report Wei, Qiang Chen, Qiang-Pu Guan, Qing-Hai Zhu, Wen-Tao World J Clin Cases Case Report BACKGROUND: Laparoscopic pancreatoduodenectomy (LPD) has been developed gradually with the advances in surgical laparoscopic techniques. It is technically challenging to perform LPD with portal vein resection and reconstruction. CASE SUMMARY: A 71-year-old female patient was diagnosed with distal cholangiocarcinoma. After preoperative examination and rigorous preoperative preparation, the patient underwent LPD using 3D laparoscopy on July 17, 2018. During the surgery, we found that the tumor invaded the right wall of the portal vein; thus, pancreaticoduodenectomy combined with partial portal vein wall resection was performed. The defect of the portal vein wall was approximately 2.5 cm × 1.0 cm. The hepatic ligamentum teres was excised by laparoscopy and then recanalized in vitro. Following recanalization, the hepatic ligamentum teres was cut longitudinally and then trimmed into vascular patches that were then used to reconstruct the defect of the portal vein through 3D laparoscopy. The operative time was 560 min, and intraoperative blood loss was 100 mL. The duration of the blood occlusion time was 63 min. No blood transfusion was required. The patient underwent enhanced recovery after surgery procedures after the operation. The patient was discharged on postoperative day 11. Follow-up for 6 months after discharge showed no stenosis of the portal vein and good patency of blood flow. CONCLUSION: It is safe and feasible to use the hepatic ligamentum teres patch to repair portal vein in LPD. However, the long-term patency of this technique for venous reconstruction requires further investigation. Baishideng Publishing Group Inc 2019-09-26 2019-09-26 /pmc/articles/PMC6789404/ /pubmed/31616706 http://dx.doi.org/10.12998/wjcc.v7.i18.2879 Text en ©The Author(s) 2019. Published by Baishideng Publishing Group Inc. All rights reserved. http://creativecommons.org/licenses/by-nc/4.0/ This article is an open-access article which was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial.
spellingShingle Case Report
Wei, Qiang
Chen, Qiang-Pu
Guan, Qing-Hai
Zhu, Wen-Tao
Repair of the portal vein using a hepatic ligamentum teres patch for laparoscopic pancreatoduodenectomy: A case report
title Repair of the portal vein using a hepatic ligamentum teres patch for laparoscopic pancreatoduodenectomy: A case report
title_full Repair of the portal vein using a hepatic ligamentum teres patch for laparoscopic pancreatoduodenectomy: A case report
title_fullStr Repair of the portal vein using a hepatic ligamentum teres patch for laparoscopic pancreatoduodenectomy: A case report
title_full_unstemmed Repair of the portal vein using a hepatic ligamentum teres patch for laparoscopic pancreatoduodenectomy: A case report
title_short Repair of the portal vein using a hepatic ligamentum teres patch for laparoscopic pancreatoduodenectomy: A case report
title_sort repair of the portal vein using a hepatic ligamentum teres patch for laparoscopic pancreatoduodenectomy: a case report
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6789404/
https://www.ncbi.nlm.nih.gov/pubmed/31616706
http://dx.doi.org/10.12998/wjcc.v7.i18.2879
work_keys_str_mv AT weiqiang repairoftheportalveinusingahepaticligamentumterespatchforlaparoscopicpancreatoduodenectomyacasereport
AT chenqiangpu repairoftheportalveinusingahepaticligamentumterespatchforlaparoscopicpancreatoduodenectomyacasereport
AT guanqinghai repairoftheportalveinusingahepaticligamentumterespatchforlaparoscopicpancreatoduodenectomyacasereport
AT zhuwentao repairoftheportalveinusingahepaticligamentumterespatchforlaparoscopicpancreatoduodenectomyacasereport