Cargando…

Comparing Four Video Laryngoscopes and One Optical Laryngoscope with a Standard Macintosh Blade in a Simulated Trapped Car Accident Victim

BACKGROUND: Tracheal intubation still represents the “gold standard” in securing the airway of unconscious patients in the prehospital setting. Especially in cases of restricted access to the patient, video laryngoscopy became more and more relevant. OBJECTIVES: The aim of the study was to evaluate...

Descripción completa

Detalles Bibliográficos
Autores principales: Raimann, Florian J., Tepperis, Daniel M., Meininger, Dirk, Zacharowski, Kai, Schalk, Richard, Byhahn, Christian, Weber, Christian F., Mutlak, Haitham
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6791209/
https://www.ncbi.nlm.nih.gov/pubmed/31662911
http://dx.doi.org/10.1155/2019/9690839
_version_ 1783458940582887424
author Raimann, Florian J.
Tepperis, Daniel M.
Meininger, Dirk
Zacharowski, Kai
Schalk, Richard
Byhahn, Christian
Weber, Christian F.
Mutlak, Haitham
author_facet Raimann, Florian J.
Tepperis, Daniel M.
Meininger, Dirk
Zacharowski, Kai
Schalk, Richard
Byhahn, Christian
Weber, Christian F.
Mutlak, Haitham
author_sort Raimann, Florian J.
collection PubMed
description BACKGROUND: Tracheal intubation still represents the “gold standard” in securing the airway of unconscious patients in the prehospital setting. Especially in cases of restricted access to the patient, video laryngoscopy became more and more relevant. OBJECTIVES: The aim of the study was to evaluate the performance and intubation success of four different video laryngoscopes, one optical laryngoscope, and a Macintosh blade while intubating from two different positions in a mannequin trial with difficult access to the patient. METHODS: A mannequin with a cervical collar was placed on the driver's seat. Intubation was performed with six different laryngoscopes either through the driver's window or from the backseat. Success, C/L score, time to best view (TTBV), time to intubation (TTI), and number of attempts were measured. All participants were asked to rate their favored device. RESULTS: Forty-two physicians participated. 100% of all intubations performed from the backseat were successful. Intubation success through the driver's window was less successful. Only with the Airtraq® optical laryngoscope, 100% success was achieved. Best visualization (window C/L 2a; backseat C/L 2a) and shortest TTBV (window 4.7 s; backseat 4.1 s) were obtained when using the D-Blade video laryngoscope, but this was not associated with a higher success through the driver's window. Fastest TTI was achieved through the window (14.2 s) when using the C-MAC video laryngoscope and from the backseat (7.3 s) when using a Macintosh blade. CONCLUSIONS: Video laryngoscopy revealed better results in visualization but was not associated with a higher success. Success depended on the approach and familiarity with the device. We believe that video laryngoscopy is suitable for securing airways in trapped accident victims. The decision for an optimal device is complicated and should be based upon experience and regular training with the device.
format Online
Article
Text
id pubmed-6791209
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-67912092019-10-29 Comparing Four Video Laryngoscopes and One Optical Laryngoscope with a Standard Macintosh Blade in a Simulated Trapped Car Accident Victim Raimann, Florian J. Tepperis, Daniel M. Meininger, Dirk Zacharowski, Kai Schalk, Richard Byhahn, Christian Weber, Christian F. Mutlak, Haitham Emerg Med Int Research Article BACKGROUND: Tracheal intubation still represents the “gold standard” in securing the airway of unconscious patients in the prehospital setting. Especially in cases of restricted access to the patient, video laryngoscopy became more and more relevant. OBJECTIVES: The aim of the study was to evaluate the performance and intubation success of four different video laryngoscopes, one optical laryngoscope, and a Macintosh blade while intubating from two different positions in a mannequin trial with difficult access to the patient. METHODS: A mannequin with a cervical collar was placed on the driver's seat. Intubation was performed with six different laryngoscopes either through the driver's window or from the backseat. Success, C/L score, time to best view (TTBV), time to intubation (TTI), and number of attempts were measured. All participants were asked to rate their favored device. RESULTS: Forty-two physicians participated. 100% of all intubations performed from the backseat were successful. Intubation success through the driver's window was less successful. Only with the Airtraq® optical laryngoscope, 100% success was achieved. Best visualization (window C/L 2a; backseat C/L 2a) and shortest TTBV (window 4.7 s; backseat 4.1 s) were obtained when using the D-Blade video laryngoscope, but this was not associated with a higher success through the driver's window. Fastest TTI was achieved through the window (14.2 s) when using the C-MAC video laryngoscope and from the backseat (7.3 s) when using a Macintosh blade. CONCLUSIONS: Video laryngoscopy revealed better results in visualization but was not associated with a higher success. Success depended on the approach and familiarity with the device. We believe that video laryngoscopy is suitable for securing airways in trapped accident victims. The decision for an optimal device is complicated and should be based upon experience and regular training with the device. Hindawi 2019-10-01 /pmc/articles/PMC6791209/ /pubmed/31662911 http://dx.doi.org/10.1155/2019/9690839 Text en Copyright © 2019 Florian J. Raimann et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Raimann, Florian J.
Tepperis, Daniel M.
Meininger, Dirk
Zacharowski, Kai
Schalk, Richard
Byhahn, Christian
Weber, Christian F.
Mutlak, Haitham
Comparing Four Video Laryngoscopes and One Optical Laryngoscope with a Standard Macintosh Blade in a Simulated Trapped Car Accident Victim
title Comparing Four Video Laryngoscopes and One Optical Laryngoscope with a Standard Macintosh Blade in a Simulated Trapped Car Accident Victim
title_full Comparing Four Video Laryngoscopes and One Optical Laryngoscope with a Standard Macintosh Blade in a Simulated Trapped Car Accident Victim
title_fullStr Comparing Four Video Laryngoscopes and One Optical Laryngoscope with a Standard Macintosh Blade in a Simulated Trapped Car Accident Victim
title_full_unstemmed Comparing Four Video Laryngoscopes and One Optical Laryngoscope with a Standard Macintosh Blade in a Simulated Trapped Car Accident Victim
title_short Comparing Four Video Laryngoscopes and One Optical Laryngoscope with a Standard Macintosh Blade in a Simulated Trapped Car Accident Victim
title_sort comparing four video laryngoscopes and one optical laryngoscope with a standard macintosh blade in a simulated trapped car accident victim
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6791209/
https://www.ncbi.nlm.nih.gov/pubmed/31662911
http://dx.doi.org/10.1155/2019/9690839
work_keys_str_mv AT raimannflorianj comparingfourvideolaryngoscopesandoneopticallaryngoscopewithastandardmacintoshbladeinasimulatedtrappedcaraccidentvictim
AT tepperisdanielm comparingfourvideolaryngoscopesandoneopticallaryngoscopewithastandardmacintoshbladeinasimulatedtrappedcaraccidentvictim
AT meiningerdirk comparingfourvideolaryngoscopesandoneopticallaryngoscopewithastandardmacintoshbladeinasimulatedtrappedcaraccidentvictim
AT zacharowskikai comparingfourvideolaryngoscopesandoneopticallaryngoscopewithastandardmacintoshbladeinasimulatedtrappedcaraccidentvictim
AT schalkrichard comparingfourvideolaryngoscopesandoneopticallaryngoscopewithastandardmacintoshbladeinasimulatedtrappedcaraccidentvictim
AT byhahnchristian comparingfourvideolaryngoscopesandoneopticallaryngoscopewithastandardmacintoshbladeinasimulatedtrappedcaraccidentvictim
AT weberchristianf comparingfourvideolaryngoscopesandoneopticallaryngoscopewithastandardmacintoshbladeinasimulatedtrappedcaraccidentvictim
AT mutlakhaitham comparingfourvideolaryngoscopesandoneopticallaryngoscopewithastandardmacintoshbladeinasimulatedtrappedcaraccidentvictim