The reliability and accuracy of operational system data in a nationwide helicopter emergency medical services mission database

AIM: The aim of this study was to evaluate the reliability and accuracy of documentation in FinnHEMS database, which is a nationwide helicopter emergency service (HEMS) clinical quality registry. METHODS: This is a nationwide study based on written fictional clinical scenarios. Study subjects were H...

Descripción completa

Detalles Bibliográficos
Autores principales: Heino, A., Iirola, T., Raatiniemi, L., Nurmi, J., Olkinuora, A., Laukkanen-Nevala, P., Virkkunen, I., Tommila, M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6792230/
https://www.ncbi.nlm.nih.gov/pubmed/31615407
http://dx.doi.org/10.1186/s12873-019-0265-y
_version_ 1783459105354022912
author Heino, A.
Iirola, T.
Raatiniemi, L.
Nurmi, J.
Olkinuora, A.
Laukkanen-Nevala, P.
Virkkunen, I.
Tommila, M.
author_facet Heino, A.
Iirola, T.
Raatiniemi, L.
Nurmi, J.
Olkinuora, A.
Laukkanen-Nevala, P.
Virkkunen, I.
Tommila, M.
author_sort Heino, A.
collection PubMed
description AIM: The aim of this study was to evaluate the reliability and accuracy of documentation in FinnHEMS database, which is a nationwide helicopter emergency service (HEMS) clinical quality registry. METHODS: This is a nationwide study based on written fictional clinical scenarios. Study subjects were HEMS physicians and paramedics, who filled in the clinical quality registry based on the clinical scenarios. The inter-rater -reliability of the collected data was analyzed with percent agreement and free-marginal multi-rater kappa. RESULTS: Dispatch coding had a percent agreement of 91% and free-marginal multi-rater kappa value of 0.83. Coding for transportation or mission cancellation resulted in an agreement of 84% and free-marginal kappa value of 0.68. An agreement of 82% and a kappa value of 0.73 for dispatcher coding was found. Mission end, arrival at hospital and HEMS unit dispatch -times had agreements from 80 to 85% and kappa values from 0.61 to 0.73. The emergency call to dispatch centre time had an agreement of 71% and kappa value of 0.56. The documentation of pain had an agreement of 73% on both the first and second measurements. All other vital parameters had less than 70% agreement and 0.40 kappa value in the first measurement. The documentation of secondary vital parameter measurements resulted in agreements from 72 to 91% and kappa values from 0.43 to 0.64. CONCLUSION: Data from HEMS operations can be gathered reliably in a national clinical quality registry. This study revealed some inaccuracies in data registration and data quality, which are important to detect to improve the overall reliability and validity of the HEMS clinical quality register.
format Online
Article
Text
id pubmed-6792230
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-67922302019-10-21 The reliability and accuracy of operational system data in a nationwide helicopter emergency medical services mission database Heino, A. Iirola, T. Raatiniemi, L. Nurmi, J. Olkinuora, A. Laukkanen-Nevala, P. Virkkunen, I. Tommila, M. BMC Emerg Med Research Article AIM: The aim of this study was to evaluate the reliability and accuracy of documentation in FinnHEMS database, which is a nationwide helicopter emergency service (HEMS) clinical quality registry. METHODS: This is a nationwide study based on written fictional clinical scenarios. Study subjects were HEMS physicians and paramedics, who filled in the clinical quality registry based on the clinical scenarios. The inter-rater -reliability of the collected data was analyzed with percent agreement and free-marginal multi-rater kappa. RESULTS: Dispatch coding had a percent agreement of 91% and free-marginal multi-rater kappa value of 0.83. Coding for transportation or mission cancellation resulted in an agreement of 84% and free-marginal kappa value of 0.68. An agreement of 82% and a kappa value of 0.73 for dispatcher coding was found. Mission end, arrival at hospital and HEMS unit dispatch -times had agreements from 80 to 85% and kappa values from 0.61 to 0.73. The emergency call to dispatch centre time had an agreement of 71% and kappa value of 0.56. The documentation of pain had an agreement of 73% on both the first and second measurements. All other vital parameters had less than 70% agreement and 0.40 kappa value in the first measurement. The documentation of secondary vital parameter measurements resulted in agreements from 72 to 91% and kappa values from 0.43 to 0.64. CONCLUSION: Data from HEMS operations can be gathered reliably in a national clinical quality registry. This study revealed some inaccuracies in data registration and data quality, which are important to detect to improve the overall reliability and validity of the HEMS clinical quality register. BioMed Central 2019-10-15 /pmc/articles/PMC6792230/ /pubmed/31615407 http://dx.doi.org/10.1186/s12873-019-0265-y Text en © The Author(s). 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Heino, A.
Iirola, T.
Raatiniemi, L.
Nurmi, J.
Olkinuora, A.
Laukkanen-Nevala, P.
Virkkunen, I.
Tommila, M.
The reliability and accuracy of operational system data in a nationwide helicopter emergency medical services mission database
title The reliability and accuracy of operational system data in a nationwide helicopter emergency medical services mission database
title_full The reliability and accuracy of operational system data in a nationwide helicopter emergency medical services mission database
title_fullStr The reliability and accuracy of operational system data in a nationwide helicopter emergency medical services mission database
title_full_unstemmed The reliability and accuracy of operational system data in a nationwide helicopter emergency medical services mission database
title_short The reliability and accuracy of operational system data in a nationwide helicopter emergency medical services mission database
title_sort reliability and accuracy of operational system data in a nationwide helicopter emergency medical services mission database
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6792230/
https://www.ncbi.nlm.nih.gov/pubmed/31615407
http://dx.doi.org/10.1186/s12873-019-0265-y
work_keys_str_mv AT heinoa thereliabilityandaccuracyofoperationalsystemdatainanationwidehelicopteremergencymedicalservicesmissiondatabase
AT iirolat thereliabilityandaccuracyofoperationalsystemdatainanationwidehelicopteremergencymedicalservicesmissiondatabase
AT raatiniemil thereliabilityandaccuracyofoperationalsystemdatainanationwidehelicopteremergencymedicalservicesmissiondatabase
AT nurmij thereliabilityandaccuracyofoperationalsystemdatainanationwidehelicopteremergencymedicalservicesmissiondatabase
AT olkinuoraa thereliabilityandaccuracyofoperationalsystemdatainanationwidehelicopteremergencymedicalservicesmissiondatabase
AT laukkanennevalap thereliabilityandaccuracyofoperationalsystemdatainanationwidehelicopteremergencymedicalservicesmissiondatabase
AT virkkuneni thereliabilityandaccuracyofoperationalsystemdatainanationwidehelicopteremergencymedicalservicesmissiondatabase
AT tommilam thereliabilityandaccuracyofoperationalsystemdatainanationwidehelicopteremergencymedicalservicesmissiondatabase
AT heinoa reliabilityandaccuracyofoperationalsystemdatainanationwidehelicopteremergencymedicalservicesmissiondatabase
AT iirolat reliabilityandaccuracyofoperationalsystemdatainanationwidehelicopteremergencymedicalservicesmissiondatabase
AT raatiniemil reliabilityandaccuracyofoperationalsystemdatainanationwidehelicopteremergencymedicalservicesmissiondatabase
AT nurmij reliabilityandaccuracyofoperationalsystemdatainanationwidehelicopteremergencymedicalservicesmissiondatabase
AT olkinuoraa reliabilityandaccuracyofoperationalsystemdatainanationwidehelicopteremergencymedicalservicesmissiondatabase
AT laukkanennevalap reliabilityandaccuracyofoperationalsystemdatainanationwidehelicopteremergencymedicalservicesmissiondatabase
AT virkkuneni reliabilityandaccuracyofoperationalsystemdatainanationwidehelicopteremergencymedicalservicesmissiondatabase
AT tommilam reliabilityandaccuracyofoperationalsystemdatainanationwidehelicopteremergencymedicalservicesmissiondatabase