Cargando…
Intra and Inter-rater Reliability between Ultrasound Imaging and Caliper Measures to determine Spring Ligament Dimensions in Cadavers
The purpose was to evaluate intra and inter-rater reliability, repeatability and absolute accuracy between ultrasound imaging (US) and caliper measures to determine Spring ligament (SL) dimensions in cadavers. SLs were identified from 62 human feet from formaldehyde-embalmed cadavers. Intra and inte...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6794374/ https://www.ncbi.nlm.nih.gov/pubmed/31616040 http://dx.doi.org/10.1038/s41598-019-51384-6 |
_version_ | 1783459277249183744 |
---|---|
author | Santiago-Nuño, Fernando Palomo-López, Patricia Becerro-de-Bengoa-Vallejo, Ricardo Calvo-Lobo, César Losa-Iglesias, Marta Elena Casado-Hernández, Israel López-López, Daniel |
author_facet | Santiago-Nuño, Fernando Palomo-López, Patricia Becerro-de-Bengoa-Vallejo, Ricardo Calvo-Lobo, César Losa-Iglesias, Marta Elena Casado-Hernández, Israel López-López, Daniel |
author_sort | Santiago-Nuño, Fernando |
collection | PubMed |
description | The purpose was to evaluate intra and inter-rater reliability, repeatability and absolute accuracy between ultrasound imaging (US) and caliper measures to determine Spring ligament (SL) dimensions in cadavers. SLs were identified from 62 human feet from formaldehyde-embalmed cadavers. Intra and inter-observer reliability, repeatability and absolute accuracy of SL width, thickness and length between US and caliper measurements were determined at intra and inter-session by intraclass correlation coefficients, Pearson´s correlation coefficients, Student t tests, standard errors of measurement, minimum detectable changes, values of normality, 95% limits of agreement, and Bland-Altman plots. Excellent inter-session and inter-rater reliability, adequate absolute accuracy, almost perfect agreement and strong correlations were shown for caliper, US and their comparison for all SL dimensions. US measurements presented higher absolute accuracy than caliper measures for SL length and thickness dimensions, while caliper displayed greater absolute accuracy for SL width dimensions. Good repeatability (P > 0.05) was shown for all SL dimensions by US, caliper and their comparison, except for SL width dimension measured with US (P = 0.019). Both US and caliper could be recommended for all SL dimensions evaluation due to their excellent reliability and absolute accuracy in cadavers, although width dimensions should be considered with caution due to US repeatability differences. |
format | Online Article Text |
id | pubmed-6794374 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-67943742019-10-25 Intra and Inter-rater Reliability between Ultrasound Imaging and Caliper Measures to determine Spring Ligament Dimensions in Cadavers Santiago-Nuño, Fernando Palomo-López, Patricia Becerro-de-Bengoa-Vallejo, Ricardo Calvo-Lobo, César Losa-Iglesias, Marta Elena Casado-Hernández, Israel López-López, Daniel Sci Rep Article The purpose was to evaluate intra and inter-rater reliability, repeatability and absolute accuracy between ultrasound imaging (US) and caliper measures to determine Spring ligament (SL) dimensions in cadavers. SLs were identified from 62 human feet from formaldehyde-embalmed cadavers. Intra and inter-observer reliability, repeatability and absolute accuracy of SL width, thickness and length between US and caliper measurements were determined at intra and inter-session by intraclass correlation coefficients, Pearson´s correlation coefficients, Student t tests, standard errors of measurement, minimum detectable changes, values of normality, 95% limits of agreement, and Bland-Altman plots. Excellent inter-session and inter-rater reliability, adequate absolute accuracy, almost perfect agreement and strong correlations were shown for caliper, US and their comparison for all SL dimensions. US measurements presented higher absolute accuracy than caliper measures for SL length and thickness dimensions, while caliper displayed greater absolute accuracy for SL width dimensions. Good repeatability (P > 0.05) was shown for all SL dimensions by US, caliper and their comparison, except for SL width dimension measured with US (P = 0.019). Both US and caliper could be recommended for all SL dimensions evaluation due to their excellent reliability and absolute accuracy in cadavers, although width dimensions should be considered with caution due to US repeatability differences. Nature Publishing Group UK 2019-10-15 /pmc/articles/PMC6794374/ /pubmed/31616040 http://dx.doi.org/10.1038/s41598-019-51384-6 Text en © The Author(s) 2019 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Article Santiago-Nuño, Fernando Palomo-López, Patricia Becerro-de-Bengoa-Vallejo, Ricardo Calvo-Lobo, César Losa-Iglesias, Marta Elena Casado-Hernández, Israel López-López, Daniel Intra and Inter-rater Reliability between Ultrasound Imaging and Caliper Measures to determine Spring Ligament Dimensions in Cadavers |
title | Intra and Inter-rater Reliability between Ultrasound Imaging and Caliper Measures to determine Spring Ligament Dimensions in Cadavers |
title_full | Intra and Inter-rater Reliability between Ultrasound Imaging and Caliper Measures to determine Spring Ligament Dimensions in Cadavers |
title_fullStr | Intra and Inter-rater Reliability between Ultrasound Imaging and Caliper Measures to determine Spring Ligament Dimensions in Cadavers |
title_full_unstemmed | Intra and Inter-rater Reliability between Ultrasound Imaging and Caliper Measures to determine Spring Ligament Dimensions in Cadavers |
title_short | Intra and Inter-rater Reliability between Ultrasound Imaging and Caliper Measures to determine Spring Ligament Dimensions in Cadavers |
title_sort | intra and inter-rater reliability between ultrasound imaging and caliper measures to determine spring ligament dimensions in cadavers |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6794374/ https://www.ncbi.nlm.nih.gov/pubmed/31616040 http://dx.doi.org/10.1038/s41598-019-51384-6 |
work_keys_str_mv | AT santiagonunofernando intraandinterraterreliabilitybetweenultrasoundimagingandcalipermeasurestodeterminespringligamentdimensionsincadavers AT palomolopezpatricia intraandinterraterreliabilitybetweenultrasoundimagingandcalipermeasurestodeterminespringligamentdimensionsincadavers AT becerrodebengoavallejoricardo intraandinterraterreliabilitybetweenultrasoundimagingandcalipermeasurestodeterminespringligamentdimensionsincadavers AT calvolobocesar intraandinterraterreliabilitybetweenultrasoundimagingandcalipermeasurestodeterminespringligamentdimensionsincadavers AT losaiglesiasmartaelena intraandinterraterreliabilitybetweenultrasoundimagingandcalipermeasurestodeterminespringligamentdimensionsincadavers AT casadohernandezisrael intraandinterraterreliabilitybetweenultrasoundimagingandcalipermeasurestodeterminespringligamentdimensionsincadavers AT lopezlopezdaniel intraandinterraterreliabilitybetweenultrasoundimagingandcalipermeasurestodeterminespringligamentdimensionsincadavers |