Cargando…

Use of IoT sensing and occupant surveys for determining the resilience of buildings to forest fire generated PM(2.5)

Wildfires and associated emissions of particulate matter pose significant environmental and health concerns. In this study we propose tools to evaluate building resilience to extreme episodes of outdoor particulate matter using a combination of indoor and outdoor IoT measurements, coupled with surve...

Descripción completa

Detalles Bibliográficos
Autores principales: Pantelic, Jovan, Dawe, Megan, Licina, Dusan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6795448/
https://www.ncbi.nlm.nih.gov/pubmed/31618240
http://dx.doi.org/10.1371/journal.pone.0223136
Descripción
Sumario:Wildfires and associated emissions of particulate matter pose significant environmental and health concerns. In this study we propose tools to evaluate building resilience to extreme episodes of outdoor particulate matter using a combination of indoor and outdoor IoT measurements, coupled with survey-based information of occupants’ perception and behaviour. We demonstrated the application of the tools on two buildings with different modes of ventilation during the Chico Camp fire event. We characterized the resilience of the buildings on different temporal and spatial scales using the well-established I/O ratio and a newly proposed E-index that evaluates indoor concentration in the context of adopted 24-hour exposure thresholds. Indoor PM(2.5) concentration during the entire Chico Camp Fire event was 21 μg/m(3) for 4(th) Street (Mechanically Ventilated) and 36 μg/m(3) for Wurster Hall (Naturally Ventilated). The cumulative median I/O ratio during the fire event was 0.27 for 4(th) Street and 0.67 for Wurster Hall. Overall E-index for 4(th) Street was 0.82, suggesting that the whole building was resilient to outdoor air pollution while overall E-index was 1.69 for Wurster Hall suggesting that interventions are necessary. The survey revealed that occupant perception of workplace air quality aligns with measured PM(2.5) in the two buildings. The results also highlight that a large portion of occupants wore face masks, even though the PM(2.5) concentration was below WHO threshold level. The results of our study demonstrate the utility of the proposed IoT-enabled and survey tools to assess the degree of protection from air pollution of outdoor origin for a single building or across a portfolio of buildings. The proposed survey tool also provides direct links between the PM(2.5) levels and occupants’ perception and behavior.