Cargando…
A single-pieced, fully air-driven, cuff-inserted pseudo-blood pressure generator for on-site pre-screening test of non-invasive blood pressure monitor by nurses
BACKGROUND: It is crucial to frequently inspect the proper operation of non-invasive electronic blood pressure monitors in various sites to prevent accidents from inaccurate blood pressure measurements, especially for large-scale hospitals. However, most conventional blood pressure monitor inspectio...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6796414/ https://www.ncbi.nlm.nih.gov/pubmed/31619241 http://dx.doi.org/10.1186/s12938-019-0719-1 |
_version_ | 1783459581774528512 |
---|---|
author | Hwang, Young Jun Kim, Gun Ho Yun, Sung Uk Nam, Kyoung Won |
author_facet | Hwang, Young Jun Kim, Gun Ho Yun, Sung Uk Nam, Kyoung Won |
author_sort | Hwang, Young Jun |
collection | PubMed |
description | BACKGROUND: It is crucial to frequently inspect the proper operation of non-invasive electronic blood pressure monitors in various sites to prevent accidents from inaccurate blood pressure measurements, especially for large-scale hospitals. However, most conventional blood pressure monitor inspection devices are not suitable for such on-site investigation purpose. In this study, we propose a new single-pieced, fully air-driven pseudo blood pressure generator that is suitable for frequent on-site pre-screening tests of the blood pressure monitor by nurses. RESULTS: The proposed model comprises a rigid cylindrical body, two simulated brachial arteries, two air-pumps, an electronic controller, and a pressure sensor. Control algorithm based on polynomial curve fitting was implemented to generate various user-instructed systolic blood pressure and heart-rate conditions automatically. To evaluate the performance and clinical feasibility of the proposed model, various experiments were performed using ten commercial electronic blood pressure monitors. Experimental results demonstrated that the values of the Pearson coefficient between the reference pseudo-blood pressure waveforms and the actually generated pressure waveforms were 0.983, 0.983 and 0.997 at 60, 70 and 80 beats/min, respectively (p < 0.05). Besides, during the experiments using ten commercial blood pressure monitors, the maximum error in average systolic blood pressure was 2.9 mmHg, the maximum standard deviation in average systolic blood pressure was 3.5 mmHg, and the maximum percentage error in average pumping rate was 3.2%, respectively. CONCLUSIONS: We expect that the proposed model can give an easy and comprehensive way for frequent on-site investigations of the blood pressure monitors by nurses, and improve the safety of patients with abnormal blood pressure, especially in most large-scale hospitals. |
format | Online Article Text |
id | pubmed-6796414 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-67964142019-10-21 A single-pieced, fully air-driven, cuff-inserted pseudo-blood pressure generator for on-site pre-screening test of non-invasive blood pressure monitor by nurses Hwang, Young Jun Kim, Gun Ho Yun, Sung Uk Nam, Kyoung Won Biomed Eng Online Research BACKGROUND: It is crucial to frequently inspect the proper operation of non-invasive electronic blood pressure monitors in various sites to prevent accidents from inaccurate blood pressure measurements, especially for large-scale hospitals. However, most conventional blood pressure monitor inspection devices are not suitable for such on-site investigation purpose. In this study, we propose a new single-pieced, fully air-driven pseudo blood pressure generator that is suitable for frequent on-site pre-screening tests of the blood pressure monitor by nurses. RESULTS: The proposed model comprises a rigid cylindrical body, two simulated brachial arteries, two air-pumps, an electronic controller, and a pressure sensor. Control algorithm based on polynomial curve fitting was implemented to generate various user-instructed systolic blood pressure and heart-rate conditions automatically. To evaluate the performance and clinical feasibility of the proposed model, various experiments were performed using ten commercial electronic blood pressure monitors. Experimental results demonstrated that the values of the Pearson coefficient between the reference pseudo-blood pressure waveforms and the actually generated pressure waveforms were 0.983, 0.983 and 0.997 at 60, 70 and 80 beats/min, respectively (p < 0.05). Besides, during the experiments using ten commercial blood pressure monitors, the maximum error in average systolic blood pressure was 2.9 mmHg, the maximum standard deviation in average systolic blood pressure was 3.5 mmHg, and the maximum percentage error in average pumping rate was 3.2%, respectively. CONCLUSIONS: We expect that the proposed model can give an easy and comprehensive way for frequent on-site investigations of the blood pressure monitors by nurses, and improve the safety of patients with abnormal blood pressure, especially in most large-scale hospitals. BioMed Central 2019-10-16 /pmc/articles/PMC6796414/ /pubmed/31619241 http://dx.doi.org/10.1186/s12938-019-0719-1 Text en © The Author(s) 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Hwang, Young Jun Kim, Gun Ho Yun, Sung Uk Nam, Kyoung Won A single-pieced, fully air-driven, cuff-inserted pseudo-blood pressure generator for on-site pre-screening test of non-invasive blood pressure monitor by nurses |
title | A single-pieced, fully air-driven, cuff-inserted pseudo-blood pressure generator for on-site pre-screening test of non-invasive blood pressure monitor by nurses |
title_full | A single-pieced, fully air-driven, cuff-inserted pseudo-blood pressure generator for on-site pre-screening test of non-invasive blood pressure monitor by nurses |
title_fullStr | A single-pieced, fully air-driven, cuff-inserted pseudo-blood pressure generator for on-site pre-screening test of non-invasive blood pressure monitor by nurses |
title_full_unstemmed | A single-pieced, fully air-driven, cuff-inserted pseudo-blood pressure generator for on-site pre-screening test of non-invasive blood pressure monitor by nurses |
title_short | A single-pieced, fully air-driven, cuff-inserted pseudo-blood pressure generator for on-site pre-screening test of non-invasive blood pressure monitor by nurses |
title_sort | single-pieced, fully air-driven, cuff-inserted pseudo-blood pressure generator for on-site pre-screening test of non-invasive blood pressure monitor by nurses |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6796414/ https://www.ncbi.nlm.nih.gov/pubmed/31619241 http://dx.doi.org/10.1186/s12938-019-0719-1 |
work_keys_str_mv | AT hwangyoungjun asinglepiecedfullyairdrivencuffinsertedpseudobloodpressuregeneratorforonsiteprescreeningtestofnoninvasivebloodpressuremonitorbynurses AT kimgunho asinglepiecedfullyairdrivencuffinsertedpseudobloodpressuregeneratorforonsiteprescreeningtestofnoninvasivebloodpressuremonitorbynurses AT yunsunguk asinglepiecedfullyairdrivencuffinsertedpseudobloodpressuregeneratorforonsiteprescreeningtestofnoninvasivebloodpressuremonitorbynurses AT namkyoungwon asinglepiecedfullyairdrivencuffinsertedpseudobloodpressuregeneratorforonsiteprescreeningtestofnoninvasivebloodpressuremonitorbynurses AT hwangyoungjun singlepiecedfullyairdrivencuffinsertedpseudobloodpressuregeneratorforonsiteprescreeningtestofnoninvasivebloodpressuremonitorbynurses AT kimgunho singlepiecedfullyairdrivencuffinsertedpseudobloodpressuregeneratorforonsiteprescreeningtestofnoninvasivebloodpressuremonitorbynurses AT yunsunguk singlepiecedfullyairdrivencuffinsertedpseudobloodpressuregeneratorforonsiteprescreeningtestofnoninvasivebloodpressuremonitorbynurses AT namkyoungwon singlepiecedfullyairdrivencuffinsertedpseudobloodpressuregeneratorforonsiteprescreeningtestofnoninvasivebloodpressuremonitorbynurses |