Cargando…

Serratus anterior muscle flap as a salvage procedure in exposed implant-based breast reconstruction

BACKGROUND: Implant-based breast reconstruction (IBR) is the most common approach to reconstruct mastectomy deffects. Infection following breast reconstruction can be devastating and lead to loss of the reconstruction due to the need of implant removal. The serratus anterior muscle flap is widely us...

Descripción completa

Detalles Bibliográficos
Autores principales: Montag, Eduardo, Okada, Alberto, Arruda, Eduardo G.P., Munhoz, Alexandre M., Busnardo, Fabio F., Gemperli, Rolf
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6796642/
https://www.ncbi.nlm.nih.gov/pubmed/31546177
http://dx.doi.org/10.1016/j.ijscr.2019.08.033
_version_ 1783459652818698240
author Montag, Eduardo
Okada, Alberto
Arruda, Eduardo G.P.
Munhoz, Alexandre M.
Busnardo, Fabio F.
Gemperli, Rolf
author_facet Montag, Eduardo
Okada, Alberto
Arruda, Eduardo G.P.
Munhoz, Alexandre M.
Busnardo, Fabio F.
Gemperli, Rolf
author_sort Montag, Eduardo
collection PubMed
description BACKGROUND: Implant-based breast reconstruction (IBR) is the most common approach to reconstruct mastectomy deffects. Infection following breast reconstruction can be devastating and lead to loss of the reconstruction due to the need of implant removal. The serratus anterior muscle flap is widely used during breast reconstruction to provide coverage of the implant/expander. METHODS: We present the application of the serratus anterior muscle flap to treat implant exposure after breast reconstruction. CASES PRESENTATION: Two patients who experienced implant exposure after breast reconstruction were successfully treated with partial capsulectomy, pocket irrigation and implant coverage with a serratus anterior muscle flap. RESULTS: No post operative complications have been observed while implant retention was achieved in both cases. CONCLUSIONS: The serratus anterior muscle flap is an option to treat implant exposure following breast reconstruction in selected cases. This flap could be used to prevent implant exposure in critical cases.
format Online
Article
Text
id pubmed-6796642
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-67966422019-10-22 Serratus anterior muscle flap as a salvage procedure in exposed implant-based breast reconstruction Montag, Eduardo Okada, Alberto Arruda, Eduardo G.P. Munhoz, Alexandre M. Busnardo, Fabio F. Gemperli, Rolf Int J Surg Case Rep Article BACKGROUND: Implant-based breast reconstruction (IBR) is the most common approach to reconstruct mastectomy deffects. Infection following breast reconstruction can be devastating and lead to loss of the reconstruction due to the need of implant removal. The serratus anterior muscle flap is widely used during breast reconstruction to provide coverage of the implant/expander. METHODS: We present the application of the serratus anterior muscle flap to treat implant exposure after breast reconstruction. CASES PRESENTATION: Two patients who experienced implant exposure after breast reconstruction were successfully treated with partial capsulectomy, pocket irrigation and implant coverage with a serratus anterior muscle flap. RESULTS: No post operative complications have been observed while implant retention was achieved in both cases. CONCLUSIONS: The serratus anterior muscle flap is an option to treat implant exposure following breast reconstruction in selected cases. This flap could be used to prevent implant exposure in critical cases. Elsevier 2019-09-13 /pmc/articles/PMC6796642/ /pubmed/31546177 http://dx.doi.org/10.1016/j.ijscr.2019.08.033 Text en © 2019 The Authors. Published by Elsevier Ltd on behalf of IJS Publishing Group Ltd. http://creativecommons.org/licenses/by/4.0/ This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Montag, Eduardo
Okada, Alberto
Arruda, Eduardo G.P.
Munhoz, Alexandre M.
Busnardo, Fabio F.
Gemperli, Rolf
Serratus anterior muscle flap as a salvage procedure in exposed implant-based breast reconstruction
title Serratus anterior muscle flap as a salvage procedure in exposed implant-based breast reconstruction
title_full Serratus anterior muscle flap as a salvage procedure in exposed implant-based breast reconstruction
title_fullStr Serratus anterior muscle flap as a salvage procedure in exposed implant-based breast reconstruction
title_full_unstemmed Serratus anterior muscle flap as a salvage procedure in exposed implant-based breast reconstruction
title_short Serratus anterior muscle flap as a salvage procedure in exposed implant-based breast reconstruction
title_sort serratus anterior muscle flap as a salvage procedure in exposed implant-based breast reconstruction
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6796642/
https://www.ncbi.nlm.nih.gov/pubmed/31546177
http://dx.doi.org/10.1016/j.ijscr.2019.08.033
work_keys_str_mv AT montageduardo serratusanteriormuscleflapasasalvageprocedureinexposedimplantbasedbreastreconstruction
AT okadaalberto serratusanteriormuscleflapasasalvageprocedureinexposedimplantbasedbreastreconstruction
AT arrudaeduardogp serratusanteriormuscleflapasasalvageprocedureinexposedimplantbasedbreastreconstruction
AT munhozalexandrem serratusanteriormuscleflapasasalvageprocedureinexposedimplantbasedbreastreconstruction
AT busnardofabiof serratusanteriormuscleflapasasalvageprocedureinexposedimplantbasedbreastreconstruction
AT gemperlirolf serratusanteriormuscleflapasasalvageprocedureinexposedimplantbasedbreastreconstruction