Cargando…

Real-Time Measurement of Ammonia (NH(3)) in Artillery Smoke Using a Passive FT-IR Remote Sensor

[Image: see text] Early alerts for avoiding exposure to toxic chemical threats are critical applications of sensors to protect both military troops and civilian populations. Among the various sensing techniques developed, the passive Fourier transform-infrared (FT-IR) spectroscopy method has been de...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Jong-Seon, Nam, Hyunwoo, Kim, Hyeon Jeong, Lee, Jae Hwan, Park, Byeong Hwang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Chemical Society 2019
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6796882/
https://www.ncbi.nlm.nih.gov/pubmed/31646221
http://dx.doi.org/10.1021/acsomega.9b01305
_version_ 1783459707928707072
author Kim, Jong-Seon
Nam, Hyunwoo
Kim, Hyeon Jeong
Lee, Jae Hwan
Park, Byeong Hwang
author_facet Kim, Jong-Seon
Nam, Hyunwoo
Kim, Hyeon Jeong
Lee, Jae Hwan
Park, Byeong Hwang
author_sort Kim, Jong-Seon
collection PubMed
description [Image: see text] Early alerts for avoiding exposure to toxic chemical threats are critical applications of sensors to protect both military troops and civilian populations. Among the various sensing techniques developed, the passive Fourier transform-infrared (FT-IR) spectroscopy method has been demonstrated to work well as a remote (kilometer-scale) sensor for such early-alert systems. The passive type FT-IR detector is capable of mobile detection of toxic gas clouds because of its small-scale interferometer and optical instruments. In this article, real-time FT-IR measurements of ammonia (NH(3)) in 76 mm artillery smoke are reported using a commercial remote sensor and scored by a real-time analysis conducted using a custom algorithm based on the generalized likelihood ratio test (GLRT). Using these methods, we measured the real-time change in the ammonia spectrum and GLRT scores against concrete and forest backgrounds following artillery propellant detonation. We confirmed that the GLRT score characteristics depend on the background and found that the effect of rapid heat transfer from the propellant detonation to the ammonia was detected in the accumulated ammonia FT-IR spectra.
format Online
Article
Text
id pubmed-6796882
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher American Chemical Society
record_format MEDLINE/PubMed
spelling pubmed-67968822019-10-23 Real-Time Measurement of Ammonia (NH(3)) in Artillery Smoke Using a Passive FT-IR Remote Sensor Kim, Jong-Seon Nam, Hyunwoo Kim, Hyeon Jeong Lee, Jae Hwan Park, Byeong Hwang ACS Omega [Image: see text] Early alerts for avoiding exposure to toxic chemical threats are critical applications of sensors to protect both military troops and civilian populations. Among the various sensing techniques developed, the passive Fourier transform-infrared (FT-IR) spectroscopy method has been demonstrated to work well as a remote (kilometer-scale) sensor for such early-alert systems. The passive type FT-IR detector is capable of mobile detection of toxic gas clouds because of its small-scale interferometer and optical instruments. In this article, real-time FT-IR measurements of ammonia (NH(3)) in 76 mm artillery smoke are reported using a commercial remote sensor and scored by a real-time analysis conducted using a custom algorithm based on the generalized likelihood ratio test (GLRT). Using these methods, we measured the real-time change in the ammonia spectrum and GLRT scores against concrete and forest backgrounds following artillery propellant detonation. We confirmed that the GLRT score characteristics depend on the background and found that the effect of rapid heat transfer from the propellant detonation to the ammonia was detected in the accumulated ammonia FT-IR spectra. American Chemical Society 2019-10-01 /pmc/articles/PMC6796882/ /pubmed/31646221 http://dx.doi.org/10.1021/acsomega.9b01305 Text en Copyright © 2019 American Chemical Society This is an open access article published under an ACS AuthorChoice License (http://pubs.acs.org/page/policy/authorchoice_termsofuse.html) , which permits copying and redistribution of the article or any adaptations for non-commercial purposes.
spellingShingle Kim, Jong-Seon
Nam, Hyunwoo
Kim, Hyeon Jeong
Lee, Jae Hwan
Park, Byeong Hwang
Real-Time Measurement of Ammonia (NH(3)) in Artillery Smoke Using a Passive FT-IR Remote Sensor
title Real-Time Measurement of Ammonia (NH(3)) in Artillery Smoke Using a Passive FT-IR Remote Sensor
title_full Real-Time Measurement of Ammonia (NH(3)) in Artillery Smoke Using a Passive FT-IR Remote Sensor
title_fullStr Real-Time Measurement of Ammonia (NH(3)) in Artillery Smoke Using a Passive FT-IR Remote Sensor
title_full_unstemmed Real-Time Measurement of Ammonia (NH(3)) in Artillery Smoke Using a Passive FT-IR Remote Sensor
title_short Real-Time Measurement of Ammonia (NH(3)) in Artillery Smoke Using a Passive FT-IR Remote Sensor
title_sort real-time measurement of ammonia (nh(3)) in artillery smoke using a passive ft-ir remote sensor
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6796882/
https://www.ncbi.nlm.nih.gov/pubmed/31646221
http://dx.doi.org/10.1021/acsomega.9b01305
work_keys_str_mv AT kimjongseon realtimemeasurementofammonianh3inartillerysmokeusingapassiveftirremotesensor
AT namhyunwoo realtimemeasurementofammonianh3inartillerysmokeusingapassiveftirremotesensor
AT kimhyeonjeong realtimemeasurementofammonianh3inartillerysmokeusingapassiveftirremotesensor
AT leejaehwan realtimemeasurementofammonianh3inartillerysmokeusingapassiveftirremotesensor
AT parkbyeonghwang realtimemeasurementofammonianh3inartillerysmokeusingapassiveftirremotesensor