Cargando…

Assessing the validity of the clinician-rated distress thermometer in palliative care

BACKGROUND: The distress of patients suffering from a terminal illness can lead to a state of despair and requests for euthanasia and assisted suicide. It is a major challenge for palliative care workers. The Distress Thermometer (DT) is recommended by the National Comprehensive Cancer Network as a...

Descripción completa

Detalles Bibliográficos
Autores principales: Van Lander, A., Tarot, A., Savanovitch, C., Pereira, B., Vennat, B., Guastella, V.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6798346/
https://www.ncbi.nlm.nih.gov/pubmed/31623591
http://dx.doi.org/10.1186/s12904-019-0466-x
_version_ 1783460016141893632
author Van Lander, A.
Tarot, A.
Savanovitch, C.
Pereira, B.
Vennat, B.
Guastella, V.
author_facet Van Lander, A.
Tarot, A.
Savanovitch, C.
Pereira, B.
Vennat, B.
Guastella, V.
author_sort Van Lander, A.
collection PubMed
description BACKGROUND: The distress of patients suffering from a terminal illness can lead to a state of despair and requests for euthanasia and assisted suicide. It is a major challenge for palliative care workers. The Distress Thermometer (DT) is recommended by the National Comprehensive Cancer Network as a means of more easily assessing distress. It is available as a Self-assessment reported Distress Thermometer, but for a wider use in palliative care it should also be implemented in the form of a clinician-reported outcome (clinRO). Clinicians need to rate patient’s distress when the patient is not able to do so (subject that cannot be addressed, defensive patient…). The primary aim of the quantitative study was to assess the validity of the Clinician-Rated Distress Thermometer in palliative care. METHOD: The assessments were performed by teams working in three palliative care centres. The primary endpoint was concordance between the patient and clinicians’ responses via Lin’s concordance coefficient. Eligible patients were aged 18 years or older, suffering from a severe disease in the palliative phase, and with a sufficient level of awareness to consent to participate in the study. A total of 51 patients were recruited, 55% were male, with a mean age of 65.8 years [39–90 years]. RESULTS: Three hundred sixty-four clinician-Rated Distress Thermometer and 467 Self-Reported Distress Thermometer were performed. Only 364 of the 467 Self-Reported Distress Thermometer were used for the study, as investigators did not systematically ask the patient to give an account of his distress. Concordance between patient and clinician responses: The Lin’s concordance coefficient with a threshold (alpha) of 5% was 0.46 [0.38; 0.54]. At the first assessment, it was 0.61 [0.44; 0.79]. The Cohen’s kappa coefficient was 0.52, with a concordance rate of 79.6%. The sensitivity was 82.9% [66.4–93.4] and the specificity 71.4% [41.9–91.6]. CONCLUSION: The first assessment gave the best results in terms of concordance between Clinician-Rated DT and Self-Reported DT. In the next assessments, the Clinician-Rated DT were less consistent with the patients’ Self-Reported DT.
format Online
Article
Text
id pubmed-6798346
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-67983462019-10-21 Assessing the validity of the clinician-rated distress thermometer in palliative care Van Lander, A. Tarot, A. Savanovitch, C. Pereira, B. Vennat, B. Guastella, V. BMC Palliat Care Research Article BACKGROUND: The distress of patients suffering from a terminal illness can lead to a state of despair and requests for euthanasia and assisted suicide. It is a major challenge for palliative care workers. The Distress Thermometer (DT) is recommended by the National Comprehensive Cancer Network as a means of more easily assessing distress. It is available as a Self-assessment reported Distress Thermometer, but for a wider use in palliative care it should also be implemented in the form of a clinician-reported outcome (clinRO). Clinicians need to rate patient’s distress when the patient is not able to do so (subject that cannot be addressed, defensive patient…). The primary aim of the quantitative study was to assess the validity of the Clinician-Rated Distress Thermometer in palliative care. METHOD: The assessments were performed by teams working in three palliative care centres. The primary endpoint was concordance between the patient and clinicians’ responses via Lin’s concordance coefficient. Eligible patients were aged 18 years or older, suffering from a severe disease in the palliative phase, and with a sufficient level of awareness to consent to participate in the study. A total of 51 patients were recruited, 55% were male, with a mean age of 65.8 years [39–90 years]. RESULTS: Three hundred sixty-four clinician-Rated Distress Thermometer and 467 Self-Reported Distress Thermometer were performed. Only 364 of the 467 Self-Reported Distress Thermometer were used for the study, as investigators did not systematically ask the patient to give an account of his distress. Concordance between patient and clinician responses: The Lin’s concordance coefficient with a threshold (alpha) of 5% was 0.46 [0.38; 0.54]. At the first assessment, it was 0.61 [0.44; 0.79]. The Cohen’s kappa coefficient was 0.52, with a concordance rate of 79.6%. The sensitivity was 82.9% [66.4–93.4] and the specificity 71.4% [41.9–91.6]. CONCLUSION: The first assessment gave the best results in terms of concordance between Clinician-Rated DT and Self-Reported DT. In the next assessments, the Clinician-Rated DT were less consistent with the patients’ Self-Reported DT. BioMed Central 2019-10-17 /pmc/articles/PMC6798346/ /pubmed/31623591 http://dx.doi.org/10.1186/s12904-019-0466-x Text en © The Author(s). 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Van Lander, A.
Tarot, A.
Savanovitch, C.
Pereira, B.
Vennat, B.
Guastella, V.
Assessing the validity of the clinician-rated distress thermometer in palliative care
title Assessing the validity of the clinician-rated distress thermometer in palliative care
title_full Assessing the validity of the clinician-rated distress thermometer in palliative care
title_fullStr Assessing the validity of the clinician-rated distress thermometer in palliative care
title_full_unstemmed Assessing the validity of the clinician-rated distress thermometer in palliative care
title_short Assessing the validity of the clinician-rated distress thermometer in palliative care
title_sort assessing the validity of the clinician-rated distress thermometer in palliative care
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6798346/
https://www.ncbi.nlm.nih.gov/pubmed/31623591
http://dx.doi.org/10.1186/s12904-019-0466-x
work_keys_str_mv AT vanlandera assessingthevalidityoftheclinicianrateddistressthermometerinpalliativecare
AT tarota assessingthevalidityoftheclinicianrateddistressthermometerinpalliativecare
AT savanovitchc assessingthevalidityoftheclinicianrateddistressthermometerinpalliativecare
AT pereirab assessingthevalidityoftheclinicianrateddistressthermometerinpalliativecare
AT vennatb assessingthevalidityoftheclinicianrateddistressthermometerinpalliativecare
AT guastellav assessingthevalidityoftheclinicianrateddistressthermometerinpalliativecare