A randomised prospective comparison of equilibration point and changing gas composition during low-flow anaesthesia with sevoflurane vs desflurane
BACKGROUND AND AIMS: Safety and economy are the main concerns while using low- flow anaesthesia with newer inhalational agents. The main objective of this study was to use and compare 'equilibration time' of sevoflurane and desflurane after change-over from high-to-low flow anaesthesia. ME...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6798620/ https://www.ncbi.nlm.nih.gov/pubmed/31649393 http://dx.doi.org/10.4103/ija.IJA_31_19 |
_version_ | 1783460086128050176 |
---|---|
author | Toal, Pratibha Chiplonkar, Sheetal Panchal, Pratik |
author_facet | Toal, Pratibha Chiplonkar, Sheetal Panchal, Pratik |
author_sort | Toal, Pratibha |
collection | PubMed |
description | BACKGROUND AND AIMS: Safety and economy are the main concerns while using low- flow anaesthesia with newer inhalational agents. The main objective of this study was to use and compare 'equilibration time' of sevoflurane and desflurane after change-over from high-to-low flow anaesthesia. METHODS: This prospective study included consenting adult patients between 18–70 years undergoing elective surgery under general anaesthesia. Patients were randomised initially to receive high-flow anaesthesia with 1.3 MAC of either desflurane or sevoflurane with nitrous oxide. After equilibration point, low-flow anaesthesia was initiated. Heart rate, non-invasive blood pressure, pulse oximeter, 5 electrode ECG and gas monitoring was done. Statistical analysis was done with the help of Med CalC version 12.5.0.0 (student version) and IBM SPSS Version 20.0. RESULTS: Mean equilibration time in sevoflurane group was higher (4.59 ± 0.77 minutes) than desflurane group (3.78 ± 0.56 minutes, P < 0.001). Inspired concentrations of both inhalational agents varied from their vaporiser settings over 2 hours, more so with sevoflurane than desflurane. Inspired oxygen concentration (FiO2) remained above 30% during anaesthesia in both groups with stable haemodynamics. CONCLUSION: Change-over from high-to-low flow anaesthesia is faster in desflurane. With fresh gas flow (FGF) of 1 L with 50% oxygen and dial concentration of 1–1.5% of sevoflurane and 3.8–4.4% of desflurane, the risk of hypoxia is minimal. The disparity between the set and delivered concentrations is more (20%) in sevoflurane than desflurane (12%). |
format | Online Article Text |
id | pubmed-6798620 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-67986202019-10-24 A randomised prospective comparison of equilibration point and changing gas composition during low-flow anaesthesia with sevoflurane vs desflurane Toal, Pratibha Chiplonkar, Sheetal Panchal, Pratik Indian J Anaesth Original Article BACKGROUND AND AIMS: Safety and economy are the main concerns while using low- flow anaesthesia with newer inhalational agents. The main objective of this study was to use and compare 'equilibration time' of sevoflurane and desflurane after change-over from high-to-low flow anaesthesia. METHODS: This prospective study included consenting adult patients between 18–70 years undergoing elective surgery under general anaesthesia. Patients were randomised initially to receive high-flow anaesthesia with 1.3 MAC of either desflurane or sevoflurane with nitrous oxide. After equilibration point, low-flow anaesthesia was initiated. Heart rate, non-invasive blood pressure, pulse oximeter, 5 electrode ECG and gas monitoring was done. Statistical analysis was done with the help of Med CalC version 12.5.0.0 (student version) and IBM SPSS Version 20.0. RESULTS: Mean equilibration time in sevoflurane group was higher (4.59 ± 0.77 minutes) than desflurane group (3.78 ± 0.56 minutes, P < 0.001). Inspired concentrations of both inhalational agents varied from their vaporiser settings over 2 hours, more so with sevoflurane than desflurane. Inspired oxygen concentration (FiO2) remained above 30% during anaesthesia in both groups with stable haemodynamics. CONCLUSION: Change-over from high-to-low flow anaesthesia is faster in desflurane. With fresh gas flow (FGF) of 1 L with 50% oxygen and dial concentration of 1–1.5% of sevoflurane and 3.8–4.4% of desflurane, the risk of hypoxia is minimal. The disparity between the set and delivered concentrations is more (20%) in sevoflurane than desflurane (12%). Wolters Kluwer - Medknow 2019-10 2019-10-10 /pmc/articles/PMC6798620/ /pubmed/31649393 http://dx.doi.org/10.4103/ija.IJA_31_19 Text en Copyright: © 2019 Indian Journal of Anaesthesia http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Toal, Pratibha Chiplonkar, Sheetal Panchal, Pratik A randomised prospective comparison of equilibration point and changing gas composition during low-flow anaesthesia with sevoflurane vs desflurane |
title | A randomised prospective comparison of equilibration point and changing gas composition during low-flow anaesthesia with sevoflurane vs desflurane |
title_full | A randomised prospective comparison of equilibration point and changing gas composition during low-flow anaesthesia with sevoflurane vs desflurane |
title_fullStr | A randomised prospective comparison of equilibration point and changing gas composition during low-flow anaesthesia with sevoflurane vs desflurane |
title_full_unstemmed | A randomised prospective comparison of equilibration point and changing gas composition during low-flow anaesthesia with sevoflurane vs desflurane |
title_short | A randomised prospective comparison of equilibration point and changing gas composition during low-flow anaesthesia with sevoflurane vs desflurane |
title_sort | randomised prospective comparison of equilibration point and changing gas composition during low-flow anaesthesia with sevoflurane vs desflurane |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6798620/ https://www.ncbi.nlm.nih.gov/pubmed/31649393 http://dx.doi.org/10.4103/ija.IJA_31_19 |
work_keys_str_mv | AT toalpratibha arandomisedprospectivecomparisonofequilibrationpointandchanginggascompositionduringlowflowanaesthesiawithsevofluranevsdesflurane AT chiplonkarsheetal arandomisedprospectivecomparisonofequilibrationpointandchanginggascompositionduringlowflowanaesthesiawithsevofluranevsdesflurane AT panchalpratik arandomisedprospectivecomparisonofequilibrationpointandchanginggascompositionduringlowflowanaesthesiawithsevofluranevsdesflurane AT toalpratibha randomisedprospectivecomparisonofequilibrationpointandchanginggascompositionduringlowflowanaesthesiawithsevofluranevsdesflurane AT chiplonkarsheetal randomisedprospectivecomparisonofequilibrationpointandchanginggascompositionduringlowflowanaesthesiawithsevofluranevsdesflurane AT panchalpratik randomisedprospectivecomparisonofequilibrationpointandchanginggascompositionduringlowflowanaesthesiawithsevofluranevsdesflurane |