A randomised prospective comparison of equilibration point and changing gas composition during low-flow anaesthesia with sevoflurane vs desflurane

BACKGROUND AND AIMS: Safety and economy are the main concerns while using low- flow anaesthesia with newer inhalational agents. The main objective of this study was to use and compare 'equilibration time' of sevoflurane and desflurane after change-over from high-to-low flow anaesthesia. ME...

Descripción completa

Detalles Bibliográficos
Autores principales: Toal, Pratibha, Chiplonkar, Sheetal, Panchal, Pratik
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6798620/
https://www.ncbi.nlm.nih.gov/pubmed/31649393
http://dx.doi.org/10.4103/ija.IJA_31_19
_version_ 1783460086128050176
author Toal, Pratibha
Chiplonkar, Sheetal
Panchal, Pratik
author_facet Toal, Pratibha
Chiplonkar, Sheetal
Panchal, Pratik
author_sort Toal, Pratibha
collection PubMed
description BACKGROUND AND AIMS: Safety and economy are the main concerns while using low- flow anaesthesia with newer inhalational agents. The main objective of this study was to use and compare 'equilibration time' of sevoflurane and desflurane after change-over from high-to-low flow anaesthesia. METHODS: This prospective study included consenting adult patients between 18–70 years undergoing elective surgery under general anaesthesia. Patients were randomised initially to receive high-flow anaesthesia with 1.3 MAC of either desflurane or sevoflurane with nitrous oxide. After equilibration point, low-flow anaesthesia was initiated. Heart rate, non-invasive blood pressure, pulse oximeter, 5 electrode ECG and gas monitoring was done. Statistical analysis was done with the help of Med CalC version 12.5.0.0 (student version) and IBM SPSS Version 20.0. RESULTS: Mean equilibration time in sevoflurane group was higher (4.59 ± 0.77 minutes) than desflurane group (3.78 ± 0.56 minutes, P < 0.001). Inspired concentrations of both inhalational agents varied from their vaporiser settings over 2 hours, more so with sevoflurane than desflurane. Inspired oxygen concentration (FiO2) remained above 30% during anaesthesia in both groups with stable haemodynamics. CONCLUSION: Change-over from high-to-low flow anaesthesia is faster in desflurane. With fresh gas flow (FGF) of 1 L with 50% oxygen and dial concentration of 1–1.5% of sevoflurane and 3.8–4.4% of desflurane, the risk of hypoxia is minimal. The disparity between the set and delivered concentrations is more (20%) in sevoflurane than desflurane (12%).
format Online
Article
Text
id pubmed-6798620
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-67986202019-10-24 A randomised prospective comparison of equilibration point and changing gas composition during low-flow anaesthesia with sevoflurane vs desflurane Toal, Pratibha Chiplonkar, Sheetal Panchal, Pratik Indian J Anaesth Original Article BACKGROUND AND AIMS: Safety and economy are the main concerns while using low- flow anaesthesia with newer inhalational agents. The main objective of this study was to use and compare 'equilibration time' of sevoflurane and desflurane after change-over from high-to-low flow anaesthesia. METHODS: This prospective study included consenting adult patients between 18–70 years undergoing elective surgery under general anaesthesia. Patients were randomised initially to receive high-flow anaesthesia with 1.3 MAC of either desflurane or sevoflurane with nitrous oxide. After equilibration point, low-flow anaesthesia was initiated. Heart rate, non-invasive blood pressure, pulse oximeter, 5 electrode ECG and gas monitoring was done. Statistical analysis was done with the help of Med CalC version 12.5.0.0 (student version) and IBM SPSS Version 20.0. RESULTS: Mean equilibration time in sevoflurane group was higher (4.59 ± 0.77 minutes) than desflurane group (3.78 ± 0.56 minutes, P < 0.001). Inspired concentrations of both inhalational agents varied from their vaporiser settings over 2 hours, more so with sevoflurane than desflurane. Inspired oxygen concentration (FiO2) remained above 30% during anaesthesia in both groups with stable haemodynamics. CONCLUSION: Change-over from high-to-low flow anaesthesia is faster in desflurane. With fresh gas flow (FGF) of 1 L with 50% oxygen and dial concentration of 1–1.5% of sevoflurane and 3.8–4.4% of desflurane, the risk of hypoxia is minimal. The disparity between the set and delivered concentrations is more (20%) in sevoflurane than desflurane (12%). Wolters Kluwer - Medknow 2019-10 2019-10-10 /pmc/articles/PMC6798620/ /pubmed/31649393 http://dx.doi.org/10.4103/ija.IJA_31_19 Text en Copyright: © 2019 Indian Journal of Anaesthesia http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Toal, Pratibha
Chiplonkar, Sheetal
Panchal, Pratik
A randomised prospective comparison of equilibration point and changing gas composition during low-flow anaesthesia with sevoflurane vs desflurane
title A randomised prospective comparison of equilibration point and changing gas composition during low-flow anaesthesia with sevoflurane vs desflurane
title_full A randomised prospective comparison of equilibration point and changing gas composition during low-flow anaesthesia with sevoflurane vs desflurane
title_fullStr A randomised prospective comparison of equilibration point and changing gas composition during low-flow anaesthesia with sevoflurane vs desflurane
title_full_unstemmed A randomised prospective comparison of equilibration point and changing gas composition during low-flow anaesthesia with sevoflurane vs desflurane
title_short A randomised prospective comparison of equilibration point and changing gas composition during low-flow anaesthesia with sevoflurane vs desflurane
title_sort randomised prospective comparison of equilibration point and changing gas composition during low-flow anaesthesia with sevoflurane vs desflurane
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6798620/
https://www.ncbi.nlm.nih.gov/pubmed/31649393
http://dx.doi.org/10.4103/ija.IJA_31_19
work_keys_str_mv AT toalpratibha arandomisedprospectivecomparisonofequilibrationpointandchanginggascompositionduringlowflowanaesthesiawithsevofluranevsdesflurane
AT chiplonkarsheetal arandomisedprospectivecomparisonofequilibrationpointandchanginggascompositionduringlowflowanaesthesiawithsevofluranevsdesflurane
AT panchalpratik arandomisedprospectivecomparisonofequilibrationpointandchanginggascompositionduringlowflowanaesthesiawithsevofluranevsdesflurane
AT toalpratibha randomisedprospectivecomparisonofequilibrationpointandchanginggascompositionduringlowflowanaesthesiawithsevofluranevsdesflurane
AT chiplonkarsheetal randomisedprospectivecomparisonofequilibrationpointandchanginggascompositionduringlowflowanaesthesiawithsevofluranevsdesflurane
AT panchalpratik randomisedprospectivecomparisonofequilibrationpointandchanginggascompositionduringlowflowanaesthesiawithsevofluranevsdesflurane