Cargando…

Comparison of a tridimensional cephalometric analysis performed on 3T-MRI compared with CBCT: a pilot study in adults

OBJECTIVE: Since the introduction of cone-beam computed tomography (CBCT) in dentistry, this technology has enabled distortion-free three-dimensional cephalometric analysis for orthodontic and orthognathic surgery diagnosis. However, CBCT is associated with significantly higher radiation exposure th...

Descripción completa

Detalles Bibliográficos
Autores principales: Maspero, Cinzia, Abate, Andrea, Bellincioni, Francesca, Cavagnetto, Davide, Lanteri, Valentina, Costa, Antonella, Farronato, Marco
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6801285/
https://www.ncbi.nlm.nih.gov/pubmed/31631241
http://dx.doi.org/10.1186/s40510-019-0293-x
_version_ 1783460540655337472
author Maspero, Cinzia
Abate, Andrea
Bellincioni, Francesca
Cavagnetto, Davide
Lanteri, Valentina
Costa, Antonella
Farronato, Marco
author_facet Maspero, Cinzia
Abate, Andrea
Bellincioni, Francesca
Cavagnetto, Davide
Lanteri, Valentina
Costa, Antonella
Farronato, Marco
author_sort Maspero, Cinzia
collection PubMed
description OBJECTIVE: Since the introduction of cone-beam computed tomography (CBCT) in dentistry, this technology has enabled distortion-free three-dimensional cephalometric analysis for orthodontic and orthognathic surgery diagnosis. However, CBCT is associated with significantly higher radiation exposure than traditional routine bidimensional examinations for orthodontic diagnosis, although low-dose protocols have markedly reduced radiation exposure over time. The objective of this preliminary feasibility study is to compare the accuracy and diagnostic capabilities of an already-validated three-dimensional cephalometric analysis on CBCT to those of an analysis on 3-T magnetic resonance imaging (3T-MRI) to assess whether the latter can deliver a comparable quality of information while avoiding radiation exposure. MATERIALS AND METHODS: In order to test the feasibility of three-dimensional cephalometry on 3T-MRI, 18 subjects (4 male; 14 female) with mean age 37.8 ± SD 10.2, who had undergone both maxillofacial CBCT and maxillofacial 3T-MRI for various purposes within 1 month, were selected from the archive of the Department of Dentistry and Maxillofacial Surgery of Fondazione Ospedale Policlinico Maggiore, IRCCS, Milano, Italy. A three-dimensional cephalometric analysis composed of ten midsagittal and four bilateral landmarks and 24 measurements (11 angular, 13 linear) was performed on both scans using Mimics Research® v. 17.0 (NV, Technologielaan 15, 3001 Leuven, Belgium). Cephalometric analysis was performed twice by two independent orthodontists for each scan, and each orthodontist repeated the measurements 3 weeks later. Statistical analysis was performed with SPSS® 20.00 for Windows (IBM® Corporation, Sommers, NY, USA). A Bland-Altman test for each cephalometric value was performed to assess the agreement between the procedures. The intraclass correlation coefficient (ICC) was used to assess interobserver and intraobserver reliability. The coefficient of variation was used to evaluate precision. RESULTS: Both procedures showed good reliability, with mean intraobserver ICCs of 0.977/0.971 for CBCT and 0.881/0.912 for MRI. The average interobserver ICCs were 0.965 for CBCT and 0.833 for MRI. A Bland-Altman analysis for the cephalometric tracing revealed a similar range of agreement between the two modalities; the bias range (mean ± SD) was − 0.25–0.66 mm (0.174 ± 0.31) for distances and − 0.41–0.54° (0.12 ± 0.33) for angles. CONCLUSIONS: Within the main limitation of this pilot study, that is, the small sample, it is possible to state that cephalometric measurements on 3T-MRI seem to possess adequate reliability and repeatability and that they show satisfying agreement with values measured on CBCTs. An MRI examination does not expose patients to ionizing radiation and could provide an alternative to CBCT for three-dimensional cephalometrics in the future.
format Online
Article
Text
id pubmed-6801285
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-68012852019-11-05 Comparison of a tridimensional cephalometric analysis performed on 3T-MRI compared with CBCT: a pilot study in adults Maspero, Cinzia Abate, Andrea Bellincioni, Francesca Cavagnetto, Davide Lanteri, Valentina Costa, Antonella Farronato, Marco Prog Orthod Research OBJECTIVE: Since the introduction of cone-beam computed tomography (CBCT) in dentistry, this technology has enabled distortion-free three-dimensional cephalometric analysis for orthodontic and orthognathic surgery diagnosis. However, CBCT is associated with significantly higher radiation exposure than traditional routine bidimensional examinations for orthodontic diagnosis, although low-dose protocols have markedly reduced radiation exposure over time. The objective of this preliminary feasibility study is to compare the accuracy and diagnostic capabilities of an already-validated three-dimensional cephalometric analysis on CBCT to those of an analysis on 3-T magnetic resonance imaging (3T-MRI) to assess whether the latter can deliver a comparable quality of information while avoiding radiation exposure. MATERIALS AND METHODS: In order to test the feasibility of three-dimensional cephalometry on 3T-MRI, 18 subjects (4 male; 14 female) with mean age 37.8 ± SD 10.2, who had undergone both maxillofacial CBCT and maxillofacial 3T-MRI for various purposes within 1 month, were selected from the archive of the Department of Dentistry and Maxillofacial Surgery of Fondazione Ospedale Policlinico Maggiore, IRCCS, Milano, Italy. A three-dimensional cephalometric analysis composed of ten midsagittal and four bilateral landmarks and 24 measurements (11 angular, 13 linear) was performed on both scans using Mimics Research® v. 17.0 (NV, Technologielaan 15, 3001 Leuven, Belgium). Cephalometric analysis was performed twice by two independent orthodontists for each scan, and each orthodontist repeated the measurements 3 weeks later. Statistical analysis was performed with SPSS® 20.00 for Windows (IBM® Corporation, Sommers, NY, USA). A Bland-Altman test for each cephalometric value was performed to assess the agreement between the procedures. The intraclass correlation coefficient (ICC) was used to assess interobserver and intraobserver reliability. The coefficient of variation was used to evaluate precision. RESULTS: Both procedures showed good reliability, with mean intraobserver ICCs of 0.977/0.971 for CBCT and 0.881/0.912 for MRI. The average interobserver ICCs were 0.965 for CBCT and 0.833 for MRI. A Bland-Altman analysis for the cephalometric tracing revealed a similar range of agreement between the two modalities; the bias range (mean ± SD) was − 0.25–0.66 mm (0.174 ± 0.31) for distances and − 0.41–0.54° (0.12 ± 0.33) for angles. CONCLUSIONS: Within the main limitation of this pilot study, that is, the small sample, it is possible to state that cephalometric measurements on 3T-MRI seem to possess adequate reliability and repeatability and that they show satisfying agreement with values measured on CBCTs. An MRI examination does not expose patients to ionizing radiation and could provide an alternative to CBCT for three-dimensional cephalometrics in the future. Springer Berlin Heidelberg 2019-10-21 /pmc/articles/PMC6801285/ /pubmed/31631241 http://dx.doi.org/10.1186/s40510-019-0293-x Text en © The Author(s). 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Research
Maspero, Cinzia
Abate, Andrea
Bellincioni, Francesca
Cavagnetto, Davide
Lanteri, Valentina
Costa, Antonella
Farronato, Marco
Comparison of a tridimensional cephalometric analysis performed on 3T-MRI compared with CBCT: a pilot study in adults
title Comparison of a tridimensional cephalometric analysis performed on 3T-MRI compared with CBCT: a pilot study in adults
title_full Comparison of a tridimensional cephalometric analysis performed on 3T-MRI compared with CBCT: a pilot study in adults
title_fullStr Comparison of a tridimensional cephalometric analysis performed on 3T-MRI compared with CBCT: a pilot study in adults
title_full_unstemmed Comparison of a tridimensional cephalometric analysis performed on 3T-MRI compared with CBCT: a pilot study in adults
title_short Comparison of a tridimensional cephalometric analysis performed on 3T-MRI compared with CBCT: a pilot study in adults
title_sort comparison of a tridimensional cephalometric analysis performed on 3t-mri compared with cbct: a pilot study in adults
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6801285/
https://www.ncbi.nlm.nih.gov/pubmed/31631241
http://dx.doi.org/10.1186/s40510-019-0293-x
work_keys_str_mv AT masperocinzia comparisonofatridimensionalcephalometricanalysisperformedon3tmricomparedwithcbctapilotstudyinadults
AT abateandrea comparisonofatridimensionalcephalometricanalysisperformedon3tmricomparedwithcbctapilotstudyinadults
AT bellincionifrancesca comparisonofatridimensionalcephalometricanalysisperformedon3tmricomparedwithcbctapilotstudyinadults
AT cavagnettodavide comparisonofatridimensionalcephalometricanalysisperformedon3tmricomparedwithcbctapilotstudyinadults
AT lanterivalentina comparisonofatridimensionalcephalometricanalysisperformedon3tmricomparedwithcbctapilotstudyinadults
AT costaantonella comparisonofatridimensionalcephalometricanalysisperformedon3tmricomparedwithcbctapilotstudyinadults
AT farronatomarco comparisonofatridimensionalcephalometricanalysisperformedon3tmricomparedwithcbctapilotstudyinadults