Evaluation of an Ultraviolet C (UVC) Light-Emitting Device for Disinfection of High Touch Surfaces in Hospital Critical Areas
Implementation of environmental cleaning and disinfection has been shown to reduce the incidences of healthcare-associated infections. The effect of an enhanced strategy for terminal room disinfection, applying the pulsed xenon-based ultraviolet light no-touch disinfection systems (PX-UVC) after the...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6801766/ https://www.ncbi.nlm.nih.gov/pubmed/31554297 http://dx.doi.org/10.3390/ijerph16193572 |
_version_ | 1783460654264352768 |
---|---|
author | Casini, Beatrice Tuvo, Benedetta Cristina, Maria Luisa Spagnolo, Anna Maria Totaro, Michele Baggiani, Angelo Privitera, Gaetano Pierpaolo |
author_facet | Casini, Beatrice Tuvo, Benedetta Cristina, Maria Luisa Spagnolo, Anna Maria Totaro, Michele Baggiani, Angelo Privitera, Gaetano Pierpaolo |
author_sort | Casini, Beatrice |
collection | PubMed |
description | Implementation of environmental cleaning and disinfection has been shown to reduce the incidences of healthcare-associated infections. The effect of an enhanced strategy for terminal room disinfection, applying the pulsed xenon-based ultraviolet light no-touch disinfection systems (PX-UVC) after the current standard operating protocol (SOP) was evaluated. In a teaching hospital, the effectiveness in reducing the total bacterial count (TBC) and in eliminating high-concern microorganisms was assessed on five high-touch surfaces in different critical areas, immediately pre- and post-cleaning and disinfection procedures (345 sampling sites). PX-UVC showed only 18% (15/85) of positive samples after treatment compared to 63% (72/115) after SOP. The effectiveness of PX-UVC was also observed in the absence of manual cleaning and application of a chemical disinfectant. According to the hygienic standards proposed by the Italian Workers Compensation Authority, 9 of 80 (11%) surfaces in operating rooms showed TBC ≥15 CFU/24 cm(2) after the SOP, while all samples were compliant applying the SOP plus PX-UVC disinfection. Clostridium difficile (CD) spores and Klebsiella pneumoniae (KPC) were isolated only after the SOP. The implementation of the standard cleaning and disinfection procedure with the integration of the PX-UVC treatment had effective results in both the reduction of hygiene failures and in control environmental contamination by high-concern microorganisms. |
format | Online Article Text |
id | pubmed-6801766 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-68017662019-10-31 Evaluation of an Ultraviolet C (UVC) Light-Emitting Device for Disinfection of High Touch Surfaces in Hospital Critical Areas Casini, Beatrice Tuvo, Benedetta Cristina, Maria Luisa Spagnolo, Anna Maria Totaro, Michele Baggiani, Angelo Privitera, Gaetano Pierpaolo Int J Environ Res Public Health Article Implementation of environmental cleaning and disinfection has been shown to reduce the incidences of healthcare-associated infections. The effect of an enhanced strategy for terminal room disinfection, applying the pulsed xenon-based ultraviolet light no-touch disinfection systems (PX-UVC) after the current standard operating protocol (SOP) was evaluated. In a teaching hospital, the effectiveness in reducing the total bacterial count (TBC) and in eliminating high-concern microorganisms was assessed on five high-touch surfaces in different critical areas, immediately pre- and post-cleaning and disinfection procedures (345 sampling sites). PX-UVC showed only 18% (15/85) of positive samples after treatment compared to 63% (72/115) after SOP. The effectiveness of PX-UVC was also observed in the absence of manual cleaning and application of a chemical disinfectant. According to the hygienic standards proposed by the Italian Workers Compensation Authority, 9 of 80 (11%) surfaces in operating rooms showed TBC ≥15 CFU/24 cm(2) after the SOP, while all samples were compliant applying the SOP plus PX-UVC disinfection. Clostridium difficile (CD) spores and Klebsiella pneumoniae (KPC) were isolated only after the SOP. The implementation of the standard cleaning and disinfection procedure with the integration of the PX-UVC treatment had effective results in both the reduction of hygiene failures and in control environmental contamination by high-concern microorganisms. MDPI 2019-09-24 2019-10 /pmc/articles/PMC6801766/ /pubmed/31554297 http://dx.doi.org/10.3390/ijerph16193572 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Casini, Beatrice Tuvo, Benedetta Cristina, Maria Luisa Spagnolo, Anna Maria Totaro, Michele Baggiani, Angelo Privitera, Gaetano Pierpaolo Evaluation of an Ultraviolet C (UVC) Light-Emitting Device for Disinfection of High Touch Surfaces in Hospital Critical Areas |
title | Evaluation of an Ultraviolet C (UVC) Light-Emitting Device for Disinfection of High Touch Surfaces in Hospital Critical Areas |
title_full | Evaluation of an Ultraviolet C (UVC) Light-Emitting Device for Disinfection of High Touch Surfaces in Hospital Critical Areas |
title_fullStr | Evaluation of an Ultraviolet C (UVC) Light-Emitting Device for Disinfection of High Touch Surfaces in Hospital Critical Areas |
title_full_unstemmed | Evaluation of an Ultraviolet C (UVC) Light-Emitting Device for Disinfection of High Touch Surfaces in Hospital Critical Areas |
title_short | Evaluation of an Ultraviolet C (UVC) Light-Emitting Device for Disinfection of High Touch Surfaces in Hospital Critical Areas |
title_sort | evaluation of an ultraviolet c (uvc) light-emitting device for disinfection of high touch surfaces in hospital critical areas |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6801766/ https://www.ncbi.nlm.nih.gov/pubmed/31554297 http://dx.doi.org/10.3390/ijerph16193572 |
work_keys_str_mv | AT casinibeatrice evaluationofanultravioletcuvclightemittingdevicefordisinfectionofhightouchsurfacesinhospitalcriticalareas AT tuvobenedetta evaluationofanultravioletcuvclightemittingdevicefordisinfectionofhightouchsurfacesinhospitalcriticalareas AT cristinamarialuisa evaluationofanultravioletcuvclightemittingdevicefordisinfectionofhightouchsurfacesinhospitalcriticalareas AT spagnoloannamaria evaluationofanultravioletcuvclightemittingdevicefordisinfectionofhightouchsurfacesinhospitalcriticalareas AT totaromichele evaluationofanultravioletcuvclightemittingdevicefordisinfectionofhightouchsurfacesinhospitalcriticalareas AT baggianiangelo evaluationofanultravioletcuvclightemittingdevicefordisinfectionofhightouchsurfacesinhospitalcriticalareas AT priviteragaetanopierpaolo evaluationofanultravioletcuvclightemittingdevicefordisinfectionofhightouchsurfacesinhospitalcriticalareas |