A Comparative 3D Finite Element Computational Study of Three Connections

Masticatory overload on dental implants is one of the causes of marginal bone resorption. The implant–abutment connection (IAC) design plays a critical role in the quality of the stress distribution, and, over the years, different designs were proposed. This study aimed to assess the mechanical beha...

Descripción completa

Detalles Bibliográficos
Autores principales: Farronato, Davide, Manfredini, Mattia, Stevanello, Andrea, Campana, Veronica, Azzi, Lorenzo, Farronato, Marco
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6803952/
https://www.ncbi.nlm.nih.gov/pubmed/31561421
http://dx.doi.org/10.3390/ma12193135