Cargando…
Influence of Thermal Parameters Related to Destabilization Treatments on Erosive Wear Resistance and Microstructural Variation of White Cast Iron Containing 18% Cr. Application of Design of Experiments and Rietveld Structural Analysis
High-Cr hypo-eutectic white cast irons are used in very demanding environments that require high resistance to erosive wear. The influence on the microstructural variation and erosive wear resistance of several fundamental factors related to the thermal treatments of these cast irons was analysed by...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6803954/ https://www.ncbi.nlm.nih.gov/pubmed/31590368 http://dx.doi.org/10.3390/ma12193252 |
_version_ | 1783461068168757248 |
---|---|
author | Gonzalez-Pociño, Alejandro Alvarez-Antolin, Florentino Asensio-Lozano, Juan |
author_facet | Gonzalez-Pociño, Alejandro Alvarez-Antolin, Florentino Asensio-Lozano, Juan |
author_sort | Gonzalez-Pociño, Alejandro |
collection | PubMed |
description | High-Cr hypo-eutectic white cast irons are used in very demanding environments that require high resistance to erosive wear. The influence on the microstructural variation and erosive wear resistance of several fundamental factors related to the thermal treatments of these cast irons was analysed by means of a fractional Design of Experiments (DoE). These factors included the ones related to the destabilization of austenite. The precipitated phases were identified by X-ray diffraction (XRD), while the Rietveld structural refinement method was used to determine their percentages by weight. Erosion wear resistance was calculated using the test defined by ASTM G76. It was concluded that the quench cooling medium does not significantly influence either erosive wear resistance or the proportion of martensite or retained austenite. The destabilization temperature is a key factor with respect to the percentage of retained austenite. In order to increase the amount of martensite and decrease the amount of retained austenite, temperatures not exceeding 1000 °C are required. An increase of 100 °C in the destabilization temperature can lead to a 25% increase in retained austenite. Moreover, tempering temperatures of around 500 °C favour an additional increase in the percentage of martensite. Erosive wear commences on the matrix constituent without initially affecting the eutectic carbides. Once the deterioration of the matrix constituent surrounding these carbides occurs, they are released. High tempering times provide an increase in resistance to erosive wear due to a second destabilization of austenite during the said tempering. |
format | Online Article Text |
id | pubmed-6803954 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-68039542019-11-18 Influence of Thermal Parameters Related to Destabilization Treatments on Erosive Wear Resistance and Microstructural Variation of White Cast Iron Containing 18% Cr. Application of Design of Experiments and Rietveld Structural Analysis Gonzalez-Pociño, Alejandro Alvarez-Antolin, Florentino Asensio-Lozano, Juan Materials (Basel) Article High-Cr hypo-eutectic white cast irons are used in very demanding environments that require high resistance to erosive wear. The influence on the microstructural variation and erosive wear resistance of several fundamental factors related to the thermal treatments of these cast irons was analysed by means of a fractional Design of Experiments (DoE). These factors included the ones related to the destabilization of austenite. The precipitated phases were identified by X-ray diffraction (XRD), while the Rietveld structural refinement method was used to determine their percentages by weight. Erosion wear resistance was calculated using the test defined by ASTM G76. It was concluded that the quench cooling medium does not significantly influence either erosive wear resistance or the proportion of martensite or retained austenite. The destabilization temperature is a key factor with respect to the percentage of retained austenite. In order to increase the amount of martensite and decrease the amount of retained austenite, temperatures not exceeding 1000 °C are required. An increase of 100 °C in the destabilization temperature can lead to a 25% increase in retained austenite. Moreover, tempering temperatures of around 500 °C favour an additional increase in the percentage of martensite. Erosive wear commences on the matrix constituent without initially affecting the eutectic carbides. Once the deterioration of the matrix constituent surrounding these carbides occurs, they are released. High tempering times provide an increase in resistance to erosive wear due to a second destabilization of austenite during the said tempering. MDPI 2019-10-05 /pmc/articles/PMC6803954/ /pubmed/31590368 http://dx.doi.org/10.3390/ma12193252 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Gonzalez-Pociño, Alejandro Alvarez-Antolin, Florentino Asensio-Lozano, Juan Influence of Thermal Parameters Related to Destabilization Treatments on Erosive Wear Resistance and Microstructural Variation of White Cast Iron Containing 18% Cr. Application of Design of Experiments and Rietveld Structural Analysis |
title | Influence of Thermal Parameters Related to Destabilization Treatments on Erosive Wear Resistance and Microstructural Variation of White Cast Iron Containing 18% Cr. Application of Design of Experiments and Rietveld Structural Analysis |
title_full | Influence of Thermal Parameters Related to Destabilization Treatments on Erosive Wear Resistance and Microstructural Variation of White Cast Iron Containing 18% Cr. Application of Design of Experiments and Rietveld Structural Analysis |
title_fullStr | Influence of Thermal Parameters Related to Destabilization Treatments on Erosive Wear Resistance and Microstructural Variation of White Cast Iron Containing 18% Cr. Application of Design of Experiments and Rietveld Structural Analysis |
title_full_unstemmed | Influence of Thermal Parameters Related to Destabilization Treatments on Erosive Wear Resistance and Microstructural Variation of White Cast Iron Containing 18% Cr. Application of Design of Experiments and Rietveld Structural Analysis |
title_short | Influence of Thermal Parameters Related to Destabilization Treatments on Erosive Wear Resistance and Microstructural Variation of White Cast Iron Containing 18% Cr. Application of Design of Experiments and Rietveld Structural Analysis |
title_sort | influence of thermal parameters related to destabilization treatments on erosive wear resistance and microstructural variation of white cast iron containing 18% cr. application of design of experiments and rietveld structural analysis |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6803954/ https://www.ncbi.nlm.nih.gov/pubmed/31590368 http://dx.doi.org/10.3390/ma12193252 |
work_keys_str_mv | AT gonzalezpocinoalejandro influenceofthermalparametersrelatedtodestabilizationtreatmentsonerosivewearresistanceandmicrostructuralvariationofwhitecastironcontaining18crapplicationofdesignofexperimentsandrietveldstructuralanalysis AT alvarezantolinflorentino influenceofthermalparametersrelatedtodestabilizationtreatmentsonerosivewearresistanceandmicrostructuralvariationofwhitecastironcontaining18crapplicationofdesignofexperimentsandrietveldstructuralanalysis AT asensiolozanojuan influenceofthermalparametersrelatedtodestabilizationtreatmentsonerosivewearresistanceandmicrostructuralvariationofwhitecastironcontaining18crapplicationofdesignofexperimentsandrietveldstructuralanalysis |