Cargando…
Endobronchial removal of uncovered stent using argon plasma coagulation via fibreoptic bronchoscopy
Bronchial stenosis is a complication of lung transplantation that often requires repeated balloon dilation, endobronchial treatments, and possibly stent placement. Endobronchial stents, particularly uncovered ones, may have several complications including excessive granulation tissue that cause airw...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley & Sons, Ltd
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6804289/ https://www.ncbi.nlm.nih.gov/pubmed/31649823 http://dx.doi.org/10.1002/rcr2.496 |
_version_ | 1783461150028988416 |
---|---|
author | Zantah, Massa Basile, Matthew Burtulato, Megan Criner, Gerard J. |
author_facet | Zantah, Massa Basile, Matthew Burtulato, Megan Criner, Gerard J. |
author_sort | Zantah, Massa |
collection | PubMed |
description | Bronchial stenosis is a complication of lung transplantation that often requires repeated balloon dilation, endobronchial treatments, and possibly stent placement. Endobronchial stents, particularly uncovered ones, may have several complications including excessive granulation tissue that cause airways obstruction and impaired mucociliary clearance, which may lead to inflammation and infections. Removal of epithelized endobronchial stents is usually done in the operating room using rigid bronchoscopy. Argon plasma coagulation (APC) has been used for removal of biliary stents. One case report described an endotracheal uncovered stent removal using this technique. APC can be used via flexible bronchoscopy, which may carry less risk of complications and can be done in an outpatient setting. In this case, we report using APC, at a low energy level, for complete removal of a totally epithelialized endobronchial uncovered stent in a patient experiencing stent‐related complications. |
format | Online Article Text |
id | pubmed-6804289 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | John Wiley & Sons, Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-68042892019-10-24 Endobronchial removal of uncovered stent using argon plasma coagulation via fibreoptic bronchoscopy Zantah, Massa Basile, Matthew Burtulato, Megan Criner, Gerard J. Respirol Case Rep Case Reports Bronchial stenosis is a complication of lung transplantation that often requires repeated balloon dilation, endobronchial treatments, and possibly stent placement. Endobronchial stents, particularly uncovered ones, may have several complications including excessive granulation tissue that cause airways obstruction and impaired mucociliary clearance, which may lead to inflammation and infections. Removal of epithelized endobronchial stents is usually done in the operating room using rigid bronchoscopy. Argon plasma coagulation (APC) has been used for removal of biliary stents. One case report described an endotracheal uncovered stent removal using this technique. APC can be used via flexible bronchoscopy, which may carry less risk of complications and can be done in an outpatient setting. In this case, we report using APC, at a low energy level, for complete removal of a totally epithelialized endobronchial uncovered stent in a patient experiencing stent‐related complications. John Wiley & Sons, Ltd 2019-10-22 /pmc/articles/PMC6804289/ /pubmed/31649823 http://dx.doi.org/10.1002/rcr2.496 Text en © 2019 The Authors. Respirology Case Reports published by John Wiley & Sons Australia, Ltd on behalf of The Asian Pacific Society of Respirology This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made. |
spellingShingle | Case Reports Zantah, Massa Basile, Matthew Burtulato, Megan Criner, Gerard J. Endobronchial removal of uncovered stent using argon plasma coagulation via fibreoptic bronchoscopy |
title | Endobronchial removal of uncovered stent using argon plasma coagulation via fibreoptic bronchoscopy |
title_full | Endobronchial removal of uncovered stent using argon plasma coagulation via fibreoptic bronchoscopy |
title_fullStr | Endobronchial removal of uncovered stent using argon plasma coagulation via fibreoptic bronchoscopy |
title_full_unstemmed | Endobronchial removal of uncovered stent using argon plasma coagulation via fibreoptic bronchoscopy |
title_short | Endobronchial removal of uncovered stent using argon plasma coagulation via fibreoptic bronchoscopy |
title_sort | endobronchial removal of uncovered stent using argon plasma coagulation via fibreoptic bronchoscopy |
topic | Case Reports |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6804289/ https://www.ncbi.nlm.nih.gov/pubmed/31649823 http://dx.doi.org/10.1002/rcr2.496 |
work_keys_str_mv | AT zantahmassa endobronchialremovalofuncoveredstentusingargonplasmacoagulationviafibreopticbronchoscopy AT basilematthew endobronchialremovalofuncoveredstentusingargonplasmacoagulationviafibreopticbronchoscopy AT burtulatomegan endobronchialremovalofuncoveredstentusingargonplasmacoagulationviafibreopticbronchoscopy AT crinergerardj endobronchialremovalofuncoveredstentusingargonplasmacoagulationviafibreopticbronchoscopy |