Cargando…

Establishment of a stable sampling method to assay mercaptoalbumin/non-mercaptoalbumin and reference ranges

Oxidative stress is reportedly associated with many diseases such as cancer, arteriosclerosis, diabetes and aging, but no practical biomarkers are currently available in actual clinical practice. Human mercaptoalbumin (HMA) and human non-mercaptoalbumin (HNA) are expected to become markers of oxidat...

Descripción completa

Detalles Bibliográficos
Autores principales: Yasukawa, Keiko, Sato, Masaya, Nojiri, Takahiro, Yoshikawa, Naoyuki, Morita, Kazuharu, Kai, Miyoko, Oike, Yumiko, Yamazaki, Tsutomu, Ikeda, Hitoshi, Yatomi, Yutaka
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6804495/
https://www.ncbi.nlm.nih.gov/pubmed/31649984
http://dx.doi.org/10.1016/j.plabm.2019.e00132
_version_ 1783461209429770240
author Yasukawa, Keiko
Sato, Masaya
Nojiri, Takahiro
Yoshikawa, Naoyuki
Morita, Kazuharu
Kai, Miyoko
Oike, Yumiko
Yamazaki, Tsutomu
Ikeda, Hitoshi
Yatomi, Yutaka
author_facet Yasukawa, Keiko
Sato, Masaya
Nojiri, Takahiro
Yoshikawa, Naoyuki
Morita, Kazuharu
Kai, Miyoko
Oike, Yumiko
Yamazaki, Tsutomu
Ikeda, Hitoshi
Yatomi, Yutaka
author_sort Yasukawa, Keiko
collection PubMed
description Oxidative stress is reportedly associated with many diseases such as cancer, arteriosclerosis, diabetes and aging, but no practical biomarkers are currently available in actual clinical practice. Human mercaptoalbumin (HMA) and human non-mercaptoalbumin (HNA) are expected to become markers of oxidative stress, but the stability of HMA/HNA has been problematic. We investigated the conditions for stabilizing HMA/HNA and found that HMA/HNA was stable at room temperature for 25 h if whole blood samples were mixed with a citrate buffer so that the citric acid concentration after mixing was 70 mM or higher and the pH of the added buffer was less than pH 6.0. Whole blood samples were then collected under the above conditions, and the reference range for HNA was set at 21.8% ± 7.4% (HMA, 78.2% ± 7.4%) based on samples from 65 volunteers (28 males and 37 females; average age, 55.0 ± 13.8 years). The clinical usefulness of HMA/HNA as an oxidative stress marker should be clarified for specific pathological conditions using the previously reported, highly accurate measurement method under the conditions required for HMA/HNA stability.
format Online
Article
Text
id pubmed-6804495
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-68044952019-10-24 Establishment of a stable sampling method to assay mercaptoalbumin/non-mercaptoalbumin and reference ranges Yasukawa, Keiko Sato, Masaya Nojiri, Takahiro Yoshikawa, Naoyuki Morita, Kazuharu Kai, Miyoko Oike, Yumiko Yamazaki, Tsutomu Ikeda, Hitoshi Yatomi, Yutaka Pract Lab Med Article Oxidative stress is reportedly associated with many diseases such as cancer, arteriosclerosis, diabetes and aging, but no practical biomarkers are currently available in actual clinical practice. Human mercaptoalbumin (HMA) and human non-mercaptoalbumin (HNA) are expected to become markers of oxidative stress, but the stability of HMA/HNA has been problematic. We investigated the conditions for stabilizing HMA/HNA and found that HMA/HNA was stable at room temperature for 25 h if whole blood samples were mixed with a citrate buffer so that the citric acid concentration after mixing was 70 mM or higher and the pH of the added buffer was less than pH 6.0. Whole blood samples were then collected under the above conditions, and the reference range for HNA was set at 21.8% ± 7.4% (HMA, 78.2% ± 7.4%) based on samples from 65 volunteers (28 males and 37 females; average age, 55.0 ± 13.8 years). The clinical usefulness of HMA/HNA as an oxidative stress marker should be clarified for specific pathological conditions using the previously reported, highly accurate measurement method under the conditions required for HMA/HNA stability. Elsevier 2019-09-12 /pmc/articles/PMC6804495/ /pubmed/31649984 http://dx.doi.org/10.1016/j.plabm.2019.e00132 Text en © 2019 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Article
Yasukawa, Keiko
Sato, Masaya
Nojiri, Takahiro
Yoshikawa, Naoyuki
Morita, Kazuharu
Kai, Miyoko
Oike, Yumiko
Yamazaki, Tsutomu
Ikeda, Hitoshi
Yatomi, Yutaka
Establishment of a stable sampling method to assay mercaptoalbumin/non-mercaptoalbumin and reference ranges
title Establishment of a stable sampling method to assay mercaptoalbumin/non-mercaptoalbumin and reference ranges
title_full Establishment of a stable sampling method to assay mercaptoalbumin/non-mercaptoalbumin and reference ranges
title_fullStr Establishment of a stable sampling method to assay mercaptoalbumin/non-mercaptoalbumin and reference ranges
title_full_unstemmed Establishment of a stable sampling method to assay mercaptoalbumin/non-mercaptoalbumin and reference ranges
title_short Establishment of a stable sampling method to assay mercaptoalbumin/non-mercaptoalbumin and reference ranges
title_sort establishment of a stable sampling method to assay mercaptoalbumin/non-mercaptoalbumin and reference ranges
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6804495/
https://www.ncbi.nlm.nih.gov/pubmed/31649984
http://dx.doi.org/10.1016/j.plabm.2019.e00132
work_keys_str_mv AT yasukawakeiko establishmentofastablesamplingmethodtoassaymercaptoalbuminnonmercaptoalbuminandreferenceranges
AT satomasaya establishmentofastablesamplingmethodtoassaymercaptoalbuminnonmercaptoalbuminandreferenceranges
AT nojiritakahiro establishmentofastablesamplingmethodtoassaymercaptoalbuminnonmercaptoalbuminandreferenceranges
AT yoshikawanaoyuki establishmentofastablesamplingmethodtoassaymercaptoalbuminnonmercaptoalbuminandreferenceranges
AT moritakazuharu establishmentofastablesamplingmethodtoassaymercaptoalbuminnonmercaptoalbuminandreferenceranges
AT kaimiyoko establishmentofastablesamplingmethodtoassaymercaptoalbuminnonmercaptoalbuminandreferenceranges
AT oikeyumiko establishmentofastablesamplingmethodtoassaymercaptoalbuminnonmercaptoalbuminandreferenceranges
AT yamazakitsutomu establishmentofastablesamplingmethodtoassaymercaptoalbuminnonmercaptoalbuminandreferenceranges
AT ikedahitoshi establishmentofastablesamplingmethodtoassaymercaptoalbuminnonmercaptoalbuminandreferenceranges
AT yatomiyutaka establishmentofastablesamplingmethodtoassaymercaptoalbuminnonmercaptoalbuminandreferenceranges