2192: Comparison of liquid Versus dry aerosol drug delivery in a 3D printed avian trachea and mainstream bronchi model

OBJECTIVES/SPECIFIC AIMS: This study investigates the process configuration parameters involved in targeted drug delivery to the avian respiratory system. Previously, direct intratracheal aerosol delivery in an avian model using a commercial atomizer was found to result in delivery of a high portion...

Descripción completa

Detalles Bibliográficos
Autores principales: Abraham Ruvalcaba, Carlos, Monroy, Roger, Tell, Lisa A., Fiorello, Christine V., Last, Jerold, Delplanque, Jean-Pierre
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cambridge University Press 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6804822/
http://dx.doi.org/10.1017/cts.2017.27
_version_ 1783461273800802304
author Abraham Ruvalcaba, Carlos
Monroy, Roger
Tell, Lisa A.
Fiorello, Christine V.
Last, Jerold
Delplanque, Jean-Pierre
author_facet Abraham Ruvalcaba, Carlos
Monroy, Roger
Tell, Lisa A.
Fiorello, Christine V.
Last, Jerold
Delplanque, Jean-Pierre
author_sort Abraham Ruvalcaba, Carlos
collection PubMed
description OBJECTIVES/SPECIFIC AIMS: This study investigates the process configuration parameters involved in targeted drug delivery to the avian respiratory system. Previously, direct intratracheal aerosol delivery in an avian model using a commercial atomizer was found to result in delivery of a high portion of the total dose into one lung lobe. We hypothesize that controlling process configuration will decrease the asymmetric distribution. METHODS/STUDY POPULATION: A 3D printed model of an avian trachea and mainstream bronchi was constructed to create a representative model for direct instillation of aerosols. Construction of the model respiratory tract included the trachea and the first mainstream bronchi bifurcation to measure left/right (L/R) distribution of aerosol delivered. Both liquid aerosol delivery (LAD) using a commercial atomizer and dry aerosol delivery (DAD) using a custom-built dry powder insufflator device were tested. Two experimental variables were controlled: (1) retraction distance from the carina and (2) centering of device shaft in the lumen of the trachea. Measurement of device efficiency (dose delivered to the 3D model at as fraction of total dose), aerosol delivery efficiency (dose captured at L/R bifurcations as a fraction of total dose), and aerosol lateralization (L/R) was conducted. RESULTS/ANTICIPATED RESULTS: The aerosol delivery efficiency for both LAD and DAD devices [73.9% (95% CI: 68.2–79.2) and 73.4% (95% CI: 55.5–91.3), respectively] did not have an appreciable difference. However, the LAD device had a higher efficiency as compared with the DAD device. The L/R distribution for the DAD device was found to be highly dependent on both retraction distance and shaft centering. Appreciable improvement in the L/R distribution was seen using the DAD device by increasing the retraction distance distal to the carina. DISCUSSION/SIGNIFICANCE OF IMPACT: The use of targeted drug delivery to treat pulmonary pathogens requires a careful design, manufacture, and therapeutic positioning of devices. In particular, clinically relevant animal models and treatment regimes requires a sound understanding of the physical processes controlling aerosol distribution in the respiratory system. By using a simulated respiratory model, many of the physical parameters of drug delivery can be tested before using a live animal model. This is especially important from an animal welfare perspective as well as an animal subject availability aspect.
format Online
Article
Text
id pubmed-6804822
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Cambridge University Press
record_format MEDLINE/PubMed
spelling pubmed-68048222019-10-28 2192: Comparison of liquid Versus dry aerosol drug delivery in a 3D printed avian trachea and mainstream bronchi model Abraham Ruvalcaba, Carlos Monroy, Roger Tell, Lisa A. Fiorello, Christine V. Last, Jerold Delplanque, Jean-Pierre J Clin Transl Sci Basic Science/Methodology OBJECTIVES/SPECIFIC AIMS: This study investigates the process configuration parameters involved in targeted drug delivery to the avian respiratory system. Previously, direct intratracheal aerosol delivery in an avian model using a commercial atomizer was found to result in delivery of a high portion of the total dose into one lung lobe. We hypothesize that controlling process configuration will decrease the asymmetric distribution. METHODS/STUDY POPULATION: A 3D printed model of an avian trachea and mainstream bronchi was constructed to create a representative model for direct instillation of aerosols. Construction of the model respiratory tract included the trachea and the first mainstream bronchi bifurcation to measure left/right (L/R) distribution of aerosol delivered. Both liquid aerosol delivery (LAD) using a commercial atomizer and dry aerosol delivery (DAD) using a custom-built dry powder insufflator device were tested. Two experimental variables were controlled: (1) retraction distance from the carina and (2) centering of device shaft in the lumen of the trachea. Measurement of device efficiency (dose delivered to the 3D model at as fraction of total dose), aerosol delivery efficiency (dose captured at L/R bifurcations as a fraction of total dose), and aerosol lateralization (L/R) was conducted. RESULTS/ANTICIPATED RESULTS: The aerosol delivery efficiency for both LAD and DAD devices [73.9% (95% CI: 68.2–79.2) and 73.4% (95% CI: 55.5–91.3), respectively] did not have an appreciable difference. However, the LAD device had a higher efficiency as compared with the DAD device. The L/R distribution for the DAD device was found to be highly dependent on both retraction distance and shaft centering. Appreciable improvement in the L/R distribution was seen using the DAD device by increasing the retraction distance distal to the carina. DISCUSSION/SIGNIFICANCE OF IMPACT: The use of targeted drug delivery to treat pulmonary pathogens requires a careful design, manufacture, and therapeutic positioning of devices. In particular, clinically relevant animal models and treatment regimes requires a sound understanding of the physical processes controlling aerosol distribution in the respiratory system. By using a simulated respiratory model, many of the physical parameters of drug delivery can be tested before using a live animal model. This is especially important from an animal welfare perspective as well as an animal subject availability aspect. Cambridge University Press 2018-05-10 /pmc/articles/PMC6804822/ http://dx.doi.org/10.1017/cts.2017.27 Text en © The Association for Clinical and Translational Science 2018 http://creativecommons.org/licenses/by/4.0/ This is an Open Access article, distributed under the terms of the Creative Commons Attribution licence (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted reuse, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Basic Science/Methodology
Abraham Ruvalcaba, Carlos
Monroy, Roger
Tell, Lisa A.
Fiorello, Christine V.
Last, Jerold
Delplanque, Jean-Pierre
2192: Comparison of liquid Versus dry aerosol drug delivery in a 3D printed avian trachea and mainstream bronchi model
title 2192: Comparison of liquid Versus dry aerosol drug delivery in a 3D printed avian trachea and mainstream bronchi model
title_full 2192: Comparison of liquid Versus dry aerosol drug delivery in a 3D printed avian trachea and mainstream bronchi model
title_fullStr 2192: Comparison of liquid Versus dry aerosol drug delivery in a 3D printed avian trachea and mainstream bronchi model
title_full_unstemmed 2192: Comparison of liquid Versus dry aerosol drug delivery in a 3D printed avian trachea and mainstream bronchi model
title_short 2192: Comparison of liquid Versus dry aerosol drug delivery in a 3D printed avian trachea and mainstream bronchi model
title_sort 2192: comparison of liquid versus dry aerosol drug delivery in a 3d printed avian trachea and mainstream bronchi model
topic Basic Science/Methodology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6804822/
http://dx.doi.org/10.1017/cts.2017.27
work_keys_str_mv AT abrahamruvalcabacarlos 2192comparisonofliquidversusdryaerosoldrugdeliveryina3dprintedaviantracheaandmainstreambronchimodel
AT monroyroger 2192comparisonofliquidversusdryaerosoldrugdeliveryina3dprintedaviantracheaandmainstreambronchimodel
AT telllisaa 2192comparisonofliquidversusdryaerosoldrugdeliveryina3dprintedaviantracheaandmainstreambronchimodel
AT fiorellochristinev 2192comparisonofliquidversusdryaerosoldrugdeliveryina3dprintedaviantracheaandmainstreambronchimodel
AT lastjerold 2192comparisonofliquidversusdryaerosoldrugdeliveryina3dprintedaviantracheaandmainstreambronchimodel
AT delplanquejeanpierre 2192comparisonofliquidversusdryaerosoldrugdeliveryina3dprintedaviantracheaandmainstreambronchimodel