Cargando…
Three‐Dimensional Echocardiography for Transcatheter Aortic Valve Replacement Sizing: A Systematic Review and Meta‐Analysis
BACKGROUND: Transcatheter aortic valve replacement (TAVR) is the standard of care for many patients with severe symptomatic aortic stenosis and relies on accurate sizing of the aortic annulus. It has been suggested that 3‐dimensional transesophageal echocardiography (3D TEE) may be used instead of m...
Autores principales: | , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6806040/ https://www.ncbi.nlm.nih.gov/pubmed/31549579 http://dx.doi.org/10.1161/JAHA.119.013463 |
_version_ | 1783461535990939648 |
---|---|
author | Rong, Lisa Q. Hameed, Irbaz Salemi, Arash Rahouma, Mohamed Khan, Faiza M. Wijeysundera, Harindra C. Angiolillo, Dominick J. Shore‐Lesserson, Linda Biondi‐Zoccai, Giuseppe Girardi, Leonard N. Fremes, Stephen E. Gaudino, Mario |
author_facet | Rong, Lisa Q. Hameed, Irbaz Salemi, Arash Rahouma, Mohamed Khan, Faiza M. Wijeysundera, Harindra C. Angiolillo, Dominick J. Shore‐Lesserson, Linda Biondi‐Zoccai, Giuseppe Girardi, Leonard N. Fremes, Stephen E. Gaudino, Mario |
author_sort | Rong, Lisa Q. |
collection | PubMed |
description | BACKGROUND: Transcatheter aortic valve replacement (TAVR) is the standard of care for many patients with severe symptomatic aortic stenosis and relies on accurate sizing of the aortic annulus. It has been suggested that 3‐dimensional transesophageal echocardiography (3D TEE) may be used instead of multidetector computed tomography (MDCT) for TAVR planning. This systematic review and meta‐analysis compared 3D TEE and MDCT for pre‐TAVR measurements. METHODS AND RESULTS: A systematic literature search was performed. The primary outcome was the correlation coefficient between 3D TEE– and MDCT‐measured annular area. Secondary outcomes were correlation coefficients for mean annular diameter, annular perimeter, and left ventricular outflow tract area; interobserver and intraobserver agreements; mean differences between 3D TEE and MDCT measurements; and pooled sensitivities, specificities, and receiver operating characteristic area under curve values of 3D TEE and MDCT for discriminating post‐TAVR paravalvular aortic regurgitation. A random effects model was used. Meta‐regression and leave‐one‐out analysis for the primary outcome were performed. Nineteen studies with a total of 1599 patients were included. Correlations between 3D TEE and MDCT annular area, annular perimeter, annular diameter, and left ventricular outflow tract area measurements were strong (0.86 [95% CI, 0.80–0.90]; 0.89 [CI, 0.82–0.93]; 0.80 [CI, 0.70–0.87]; and 0.78 [CI, 0.61–0.88], respectively). Mean differences between 3D TEE and MDCT between measurements were small and nonsignificant. Interobserver and intraobserver agreement and discriminatory abilities for paravalvular aortic regurgitation were good for both 3D TEE and MDCT. CONCLUSIONS: For pre‐TAVR planning, 3D TEE is comparable to MDCT. In patients with renal dysfunction, 3D TEE may be potentially advantageous for TAVR measurements because of the lack of contrast exposure. |
format | Online Article Text |
id | pubmed-6806040 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-68060402019-10-28 Three‐Dimensional Echocardiography for Transcatheter Aortic Valve Replacement Sizing: A Systematic Review and Meta‐Analysis Rong, Lisa Q. Hameed, Irbaz Salemi, Arash Rahouma, Mohamed Khan, Faiza M. Wijeysundera, Harindra C. Angiolillo, Dominick J. Shore‐Lesserson, Linda Biondi‐Zoccai, Giuseppe Girardi, Leonard N. Fremes, Stephen E. Gaudino, Mario J Am Heart Assoc Systematic Review and Meta‐analysis BACKGROUND: Transcatheter aortic valve replacement (TAVR) is the standard of care for many patients with severe symptomatic aortic stenosis and relies on accurate sizing of the aortic annulus. It has been suggested that 3‐dimensional transesophageal echocardiography (3D TEE) may be used instead of multidetector computed tomography (MDCT) for TAVR planning. This systematic review and meta‐analysis compared 3D TEE and MDCT for pre‐TAVR measurements. METHODS AND RESULTS: A systematic literature search was performed. The primary outcome was the correlation coefficient between 3D TEE– and MDCT‐measured annular area. Secondary outcomes were correlation coefficients for mean annular diameter, annular perimeter, and left ventricular outflow tract area; interobserver and intraobserver agreements; mean differences between 3D TEE and MDCT measurements; and pooled sensitivities, specificities, and receiver operating characteristic area under curve values of 3D TEE and MDCT for discriminating post‐TAVR paravalvular aortic regurgitation. A random effects model was used. Meta‐regression and leave‐one‐out analysis for the primary outcome were performed. Nineteen studies with a total of 1599 patients were included. Correlations between 3D TEE and MDCT annular area, annular perimeter, annular diameter, and left ventricular outflow tract area measurements were strong (0.86 [95% CI, 0.80–0.90]; 0.89 [CI, 0.82–0.93]; 0.80 [CI, 0.70–0.87]; and 0.78 [CI, 0.61–0.88], respectively). Mean differences between 3D TEE and MDCT between measurements were small and nonsignificant. Interobserver and intraobserver agreement and discriminatory abilities for paravalvular aortic regurgitation were good for both 3D TEE and MDCT. CONCLUSIONS: For pre‐TAVR planning, 3D TEE is comparable to MDCT. In patients with renal dysfunction, 3D TEE may be potentially advantageous for TAVR measurements because of the lack of contrast exposure. John Wiley and Sons Inc. 2019-09-24 /pmc/articles/PMC6806040/ /pubmed/31549579 http://dx.doi.org/10.1161/JAHA.119.013463 Text en © 2019 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley. This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made. |
spellingShingle | Systematic Review and Meta‐analysis Rong, Lisa Q. Hameed, Irbaz Salemi, Arash Rahouma, Mohamed Khan, Faiza M. Wijeysundera, Harindra C. Angiolillo, Dominick J. Shore‐Lesserson, Linda Biondi‐Zoccai, Giuseppe Girardi, Leonard N. Fremes, Stephen E. Gaudino, Mario Three‐Dimensional Echocardiography for Transcatheter Aortic Valve Replacement Sizing: A Systematic Review and Meta‐Analysis |
title | Three‐Dimensional Echocardiography for Transcatheter Aortic Valve Replacement Sizing: A Systematic Review and Meta‐Analysis |
title_full | Three‐Dimensional Echocardiography for Transcatheter Aortic Valve Replacement Sizing: A Systematic Review and Meta‐Analysis |
title_fullStr | Three‐Dimensional Echocardiography for Transcatheter Aortic Valve Replacement Sizing: A Systematic Review and Meta‐Analysis |
title_full_unstemmed | Three‐Dimensional Echocardiography for Transcatheter Aortic Valve Replacement Sizing: A Systematic Review and Meta‐Analysis |
title_short | Three‐Dimensional Echocardiography for Transcatheter Aortic Valve Replacement Sizing: A Systematic Review and Meta‐Analysis |
title_sort | three‐dimensional echocardiography for transcatheter aortic valve replacement sizing: a systematic review and meta‐analysis |
topic | Systematic Review and Meta‐analysis |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6806040/ https://www.ncbi.nlm.nih.gov/pubmed/31549579 http://dx.doi.org/10.1161/JAHA.119.013463 |
work_keys_str_mv | AT ronglisaq threedimensionalechocardiographyfortranscatheteraorticvalvereplacementsizingasystematicreviewandmetaanalysis AT hameedirbaz threedimensionalechocardiographyfortranscatheteraorticvalvereplacementsizingasystematicreviewandmetaanalysis AT salemiarash threedimensionalechocardiographyfortranscatheteraorticvalvereplacementsizingasystematicreviewandmetaanalysis AT rahoumamohamed threedimensionalechocardiographyfortranscatheteraorticvalvereplacementsizingasystematicreviewandmetaanalysis AT khanfaizam threedimensionalechocardiographyfortranscatheteraorticvalvereplacementsizingasystematicreviewandmetaanalysis AT wijeysunderaharindrac threedimensionalechocardiographyfortranscatheteraorticvalvereplacementsizingasystematicreviewandmetaanalysis AT angiolillodominickj threedimensionalechocardiographyfortranscatheteraorticvalvereplacementsizingasystematicreviewandmetaanalysis AT shorelessersonlinda threedimensionalechocardiographyfortranscatheteraorticvalvereplacementsizingasystematicreviewandmetaanalysis AT biondizoccaigiuseppe threedimensionalechocardiographyfortranscatheteraorticvalvereplacementsizingasystematicreviewandmetaanalysis AT girardileonardn threedimensionalechocardiographyfortranscatheteraorticvalvereplacementsizingasystematicreviewandmetaanalysis AT fremesstephene threedimensionalechocardiographyfortranscatheteraorticvalvereplacementsizingasystematicreviewandmetaanalysis AT gaudinomario threedimensionalechocardiographyfortranscatheteraorticvalvereplacementsizingasystematicreviewandmetaanalysis |